Investigating gait-responsive somatosensory cueing from a wearable device to improve walking in Parkinson’s disease

被引:0
|
作者
Dongli Li
Andre Hallack
Sophie Gwilym
Dongcheng Li
Michele T. Hu
James Cantley
机构
[1] University of Oxford,Department of Physiology, Anatomy and Genetics
[2] Oxfordshire Neurophysiotherapy,Department of Computer Science
[3] The Bosworth Clinic,Oxford Parkinson’s Disease Centre
[4] Quarry Court,Nuffield Department of Clinical Neurosciences, Division of Neurology
[5] University of Texas at Dallas,Division of Systems Medicine, Ninewells Hospital & Medical School
[6] University of Oxford,undefined
[7] University of Oxford,undefined
[8] University of Dundee,undefined
关键词
Parkinson’s disease; Freezing of gait; Cueing; Somatosensory; Wearable; Vibration; Machine learning; Movement; Festination;
D O I
暂无
中图分类号
学科分类号
摘要
Freezing-of-gait (FOG) and impaired walking are common features of Parkinson’s disease (PD). Provision of external stimuli (cueing) can improve gait, however, many cueing methods are simplistic, increase task loading or have limited utility in a real-world setting. Closed-loop (automated) somatosensory cueing systems have the potential to deliver personalised, discrete cues at the appropriate time, without requiring user input. Further development of cue delivery methods and FOG-detection are required to achieve this. In this feasibility study, we aimed to test if FOG-initiated vibration cues applied to the lower-leg via wearable devices can improve gait in PD, and to develop real-time FOG-detection algorithms. 17 participants with Parkinson’s disease and daily FOG were recruited. During 1 h study sessions, participants undertook 4 complex walking circuits, each with a different intervention: continuous rhythmic vibration cueing (CC), responsive cueing (RC; cues initiated by the research team in response to FOG), device worn with no cueing (NC), or no device (ND). Study sessions were grouped into 3 stages/blocks (A-C), separated by a gap of several weeks, enabling improvements to circuit design and the cueing device to be implemented. Video and onboard inertial measurement unit (IMU) data were analyzed for FOG events and gait metrics. RC significantly improved circuit completion times demonstrating improved overall performance across a range of walking activities. Step frequency was significantly enhanced by RC during stages B and C. During stage C, > 10 FOG events were recorded in 45% of participants without cueing (NC), which was significantly reduced by RC. A machine learning framework achieved 83% sensitivity and 80% specificity for FOG detection using IMU data. Together, these data support the feasibility of closed-loop cueing approaches coupling real-time FOG detection with responsive somatosensory lower-leg cueing to improve gait in PD.
引用
收藏
相关论文
共 50 条
  • [1] Investigating gait-responsive somatosensory cueing from a wearable device to improve walking in Parkinson's disease
    Li, Dongli
    Hallack, Andre
    Gwilym, Sophie
    Li, Dongcheng
    Hu, Michele T.
    Cantley, James
    BIOMEDICAL ENGINEERING ONLINE, 2023, 22 (01)
  • [2] The effect of rhythmic somatosensory cueing on gait in patients with Parkinson's disease
    van Wegen, E.
    de Goede, C.
    Lim, I.
    Rietberg, M.
    Nieuwboer, A.
    Willems, A.
    Jones, D.
    Rochester, L.
    Hetherington, V.
    Berendse, H.
    Zijlmans, J.
    Wolters, E.
    Kwakkel, G.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2006, 248 (1-2) : 210 - 214
  • [3] A WEARABLE DEVICE OF GAIT TRACKING FOR PARKINSON'S DISEASE PATIENTS
    Lee, Chien-Nan
    Fong, Vai Hong
    Chu, Yiu-Tong
    Cheng, Ling
    Chuang, Han-Wei
    Lo, Chun-Yi
    PROCEEDINGS OF 2018 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS (ICMLC), VOL 2, 2018, : 462 - 466
  • [4] A Technological Review of Wearable Cueing Devices Addressing Freezing of Gait in Parkinson's Disease
    Sweeney, Dean
    Quinlan, Leo R.
    Browne, Patrick
    Richardson, Margaret
    Meskell, Pauline
    OLaighin, Gearoid
    SENSORS, 2019, 19 (06)
  • [5] Effects of wearable visual cueing on gait pattern and stability in patients with Parkinson's disease
    Zhang, Wei
    Han, Yun
    Shi, Yuanyuan
    Yan, Shilei
    Song, Wenjing
    Cui, Guiyun
    Xiang, Jie
    FRONTIERS IN NEUROLOGY, 2023, 14
  • [6] Holocue: A Wearable Holographic Cueing Application for Alleviating Freezing of Gait in Parkinson's Disease
    Geerse, Daphne J.
    Coolen, Bert
    van Hilten, Jacobus J.
    Roerdink, Melvyn
    FRONTIERS IN NEUROLOGY, 2022, 12
  • [7] Cueing Paradigms to Improve Gait and Posture in Parkinson's Disease: A Narrative Review
    Muthukrishnan, Niveditha
    Abbas, James J.
    Shill, Holly A.
    Krishnamurthi, Narayanan
    SENSORS, 2019, 19 (24)
  • [8] Does visual cueing improve gait initiation in people with Parkinson's disease?
    Russo, Yuri
    Stuart, Samuel
    Batista, Carla Silva
    Brumbach, Barbara
    Vannozzi, Giuseppe
    Mancini, Martina
    HUMAN MOVEMENT SCIENCE, 2022, 84
  • [9] The Efficacy of a Newly Developed Cueing Device for Gait Mobility in Parkinson's Disease
    Suputtitada, Areerat
    Chen, Carl P. C.
    Pongmala, Chatkaew
    Sriyudthsak, Mana
    Wilhelm, Agnes
    Somboon, Pakpum
    Janssen, Jessie
    Richards, Jim
    PARKINSONS DISEASE, 2022, 2022
  • [10] Wearable biofeedback device to assess gait features and improve gait pattern in people with parkinson's disease: a case series
    Bowman, Thomas
    Pergolini, Andrea
    Carrozza, Maria Chiara
    Lencioni, Tiziana
    Marzegan, Alberto
    Meloni, Mario
    Vitiello, Nicola
    Crea, Simona
    Cattaneo, Davide
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2024, 21 (01)