Characterization of Melt Flow Index of Commercial Polystyrene Using Data from Interlaboratory Comparison

被引:0
|
作者
A. Abdel-Hakim
Ahmed M. Al-harbi
A. M. Sadek
机构
[1] National Institute of Standards (NIS),Polymer Metrology and Technology Laboratory
[2] Saudi Standards Metrology and Quality Organization (SASO),Textile Laboratory
[3] National Institute of Standards (NIS),Ionizing Radiation Metrology Department
来源
MAPAN | 2021年 / 36卷
关键词
Melt flow index; Interlaboratory comparison; Homogeneity and stability; Reference material; Polystyrene;
D O I
暂无
中图分类号
学科分类号
摘要
The melt flow index (MFI) of commercial polystyrene samples has been investigated throughout an interlaboratory comparison study. The homogeneity samples have been assessed prior to the distribution over the participants. The one-factor analysis of variance model has been applied to separate and evaluate the uncertainty components arising from the analytical method and the heterogeneity of the samples. It has been shown that the samples are sufficiently homogenous. The stability of the samples has been monitored over 6 months. The stability and the uncertainty arising from the instability of the samples have been evaluated throughout the linear regression analysis. No significant trend could be detected over the stability assessment period. The results reported by the participants have been investigated. An almost normal distribution shape has been obtained with no evidence for outlier or systematic bias. The MFI value has been evaluated as consensus value from the results reported by the participants with a standard combined uncertainty of ~ 2.2%.
引用
收藏
页码:47 / 58
页数:11
相关论文
共 50 条
  • [41] Polyphenylene Oxide - 3 - Determination of the Stabilizer Efficiency Based on Intrinsic Viscosity and Melt Flow Index Data.
    Penczek, Irena
    Bialy, Jan
    [J]. Polimery, 1973, 18 (02): : 126 - 128
  • [42] CHARACTERIZATION OF AMBIENT OZONE CONCENTRATIONS IN COMMERCIAL TIMBERLANDS USING AVAILABLE MONITORING DATA
    PINKERTON, JE
    LEFOHN, AS
    [J]. TAPPI JOURNAL, 1986, 69 (04): : 58 - 62
  • [43] Comparison of EV characterization by commercial high-sensitivity flow cytometers and a custom single-molecule flow cytometer
    Kim, James
    Xu, Shihan
    Jung, Seung-Ryoung
    Nguyen, Alya
    Cheng, Yuanhua
    Zhao, Mengxia
    Fujimoto, Bryant S.
    Nelson, Wyatt
    Schiro, Perry
    Franklin, Jeffrey L.
    Higginbotham, James N.
    Coffey, Robert J.
    Shi, Min
    Vojtech, Lucia N.
    Hladik, Florian
    Tewari, Muneesh
    Tigges, John
    Ghiran, Ionita
    Jovanovic-Talisman, Tijana
    Laurent, Louise C.
    Das, Saumya
    Gololobova, Olesia
    Witwer, Kenneth W.
    Xu, Tuoye
    Charest, Al
    Jensen, Kendall Van Keuren
    Raffai, Robert L.
    Jones, Jennifer C.
    Welsh, Joshua A.
    Nolan, John P.
    Chiu, Daniel T.
    [J]. JOURNAL OF EXTRACELLULAR VESICLES, 2024, 13 (08)
  • [44] POOLED DATA FROM COMMERCIAL CASES USING THE UROLIFT® DEVICE
    Cozzi, Paul
    Walsh, Lance
    Grier, Douglas
    Hirsh, Andrew
    Eure, Gregg
    [J]. JOURNAL OF UROLOGY, 2017, 197 (04): : E336 - E337
  • [45] Comparison of different labelling index formulae used on bromodeoxyuridine-flow cytometry data
    Johansson, MC
    Johansson, R
    Baldetorp, B
    Oredsson, SM
    [J]. CYTOMETRY, 1998, 32 (03): : 233 - 240
  • [46] Are there better indices for evaluation purposes than the h index?: a comparison of nine different variants of the h index using data from biomedicine
    Bornmann, Lutz
    Mutz, Ruediger
    Daniel, Hans-Dieter
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR INFORMATION SCIENCE AND TECHNOLOGY, 2008, 59 (05): : 830 - 837
  • [47] Assessment of a Price Index for Hospital Outpatient Department Services Using Commercial Claims Data in Massachusetts
    James, Hannah O.
    Fonkych, Katya
    Nasuti, Laura J.
    Auerbach, David I.
    [J]. JAMA HEALTH FORUM, 2023, 4 (04): : E230650
  • [48] Detection of nanocellulose in commercial products and its size characterization using asymmetric flow field-flow fractionation
    Ruiz-Palomero, Celia
    Laura Soriano, M.
    Valcarcel, Miguel
    [J]. MICROCHIMICA ACTA, 2017, 184 (04) : 1069 - 1076
  • [49] Detection of nanocellulose in commercial products and its size characterization using asymmetric flow field-flow fractionation
    Celia Ruiz-Palomero
    M. Laura Soriano
    Miguel Valcárcel
    [J]. Microchimica Acta, 2017, 184 : 1069 - 1076
  • [50] A Bundled-Data Asynchronous Circuit Synthesis Flow Using a Commercial EDA Framework
    Gibiluka, Matheus
    Moreira, Matheus Trevisan
    Vilar Calazans, Ney Laert
    [J]. 2015 EUROMICRO CONFERENCE ON DIGITAL SYSTEM DESIGN (DSD), 2015, : 79 - 86