Dose Verification for Tumor Motion with Different Treatment Planning Systems: A Dynamic Thorax Phantom Study

被引:0
|
作者
Shih-Neng Yang
Chun-Wei Lin
Mu-Bai Chang
Geoffrey G. Zhang
Kuei-Ting Chou
Yu-Rou Chiou
Shung-Shung Sun
Louis Lui
Tsung-Jung Ho
Tzung-Chi Huang
机构
[1] China Medical University,Department of Biomedical Imaging and Radiological Science
[2] China Medical University Hospital,Department of Radiation Oncology
[3] Cathay General Hospital,Department of Radiation Oncology
[4] Tainan Municipal An-Nan Hospital,Department of Radiation Oncology
[5] Moffitt Cancer Center,Department of Radiation Oncology
[6] China Medical University Hospital,Department of Nuclear Medicine and PET Center
[7] China Medical University,College of Chinese Medicine
[8] Asia University,Department of Bioinformatics and Medical Engineering
关键词
Four-dimensional computed tomography; Maximum-intensity projection; Respiratory motion; Dose verification;
D O I
暂无
中图分类号
学科分类号
摘要
During radiation therapy for lung cancer, the respiratory motion of the target increases error and affects the treatment outcome. A four-dimensional computed tomography (4D-CT) technology developed recently can be used to obtain snapshot thoracic CT images during the entire respiratory cycle, which can be helpful in visualization of the tumor displacement in respiratory motion. This study employed a dynamic phantom to simulate tumor respiratory motion, with motion amplitudes of 2, 5 and 10 mm in the superior-inferior direction and motion periods of 4 and 6 s. 4D-CT imaging was applied to record the movement of the target, and maximum-intensity projection (MIP) imaging was used to define the internal target volume (ITV). Treatment plans were generated using three different treatment techniques—tomotherapy, intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). In addition, using interchangeable insert modules (an ionization chamber for point dose measurement and Gafchromic EBT3 film for planar dose distribution) in the dynamic phantom, the dose received by the target was measured. The dose received with motion was compared with that received under stationary conditions for dose errors due to respiratory motion. The point dose differences between moving and stationary conditions for tomotherapy, IMRT and VMAT were 0.48 ± 0.51%, 0.17 ± 0.45%, and 0.68 ± 0.70%, respectively; and at motion amplitudes of 2, 5, and 10 mm, the mean dose differences were 0.27 ± 0.38%, 0.37 ± 0.55% and 0.68 ± 0.74%, respectively. Based on planar dose analysis, at motion amplitudes of 2 and 5 mm, the dose distribution differences between moving and stationary conditions using the three treatment methods were all very small, and all passed the gamma index test with a criterion of 3%/3 mm, while at an amplitude of 10 mm, the edge of the ITV was associated with significantly greater dose errors. As studies have shown that in only approximately 10% of pulmonary tumors move with an amplitude >10 mm, 4D-CT MIP imaging in combination with delineation of the ITV may resolve the issue of dose error in most cases. For tumors with large motion amplitudes due to respiration, respiratory gating method may be used to reduce healthy lung tissues inside treatment field.
引用
收藏
页码:46 / 54
页数:8
相关论文
共 50 条
  • [1] Dose Verification for Tumor Motion with Different Treatment Planning Systems: A Dynamic Thorax Phantom Study
    Yang, Shih-Neng
    Lin, Chun-Wei
    Chang, Mu-Bai
    Zhang, Geoffrey G.
    Chou, Kuei-Ting
    Chiou, Yu-Rou
    Sun, Shung-Shung
    Lui, Louis
    Ho, Tsung-Jung
    Huang, Tzung-Chi
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2018, 38 (01) : 46 - 54
  • [2] A feasibility study of dynamic verification for tumor target delineation and dose delivery using a six degrees of freedom motion phantom
    Xu, G.
    Xiong, Z.
    Wang, H.
    Jiang, H.
    Li, B.
    Liu, L.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (04): : 411 - 420
  • [3] Technical note: Heterogeneity dose calculation accuracy in IMRT: Study of five commercial treatment planning systems using an anthropomorphic thorax phantom
    Davidson, Scott E.
    Popple, Richard A.
    Ibbott, Geoffrey S.
    Followill, David S.
    MEDICAL PHYSICS, 2008, 35 (12) : 5434 - 5439
  • [4] A phantom for brachytherapy treatment planning systems verification with the ArcCHECK® device
    Chelminski, K.
    Sobotka, P.
    Buczek, B.
    Gruszczynska, E.
    Bulski, W.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S707 - S707
  • [5] Thermoluminescence dosimetry dose verification of a high dose rate brachytherapy treatment planning in phantom
    Sakulsingharoj, S.
    Tangboonduangjit, P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S328 - S328
  • [6] The evaluation of several commercial IMRT treatment planning systems heterogeneity dose calculation algorithms using an anthropomorphic thorax phantom
    Davidson, S
    Followill, D
    Ibbott, G
    Prado, K
    MEDICAL PHYSICS, 2005, 32 (06) : 1988 - 1988
  • [7] End-to-end verification of DIBH Treatment technique using CIRS Dynamic Thorax phantom
    Pillai, S.
    McInally, N.
    Lambert, A.
    Monteith, Z.
    Robertson, F.
    Sutton, D.
    Nailon, W.
    Huang, Z.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1366 - S1367
  • [8] Dynamic anthropomorphic thorax phantom for quality assurance of motion management in radiotherapy
    Abdollahi, Sara
    Mowlavi, Ali Asghar
    Yazdi, Mohammad Hadi Hadizadeh
    Ceberg, Sofie
    Aznar, Marianne Camille
    Tabrizi, Fatemeh Varshoee
    Salek, Roham
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 30
  • [9] dynamic anthropomorphic thorax phantom for quality assurance of motion management in radiotherapy
    Abdollahi, Sara
    Mowlavi, Ali Asghar
    Yazdi, Mohammad Hadi Hadizadeh
    Ceberg, Sofie
    Aznar, Marianne Camille
    Tabrizi, Fatemeh Varshoee
    Salek, Roham
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3281 - S3285
  • [10] VERIFICATION OF MONTE CARLO DOSE CALCULATIONS IN AN ANTHROPOMORPHIC THORAX PHANTOM FOR CYBERKNIFE TREATMENT OF SMALL LUNG TUMOURS.
    Marijnissen, H.
    Hol, M.
    van der Baan, P.
    Heijmen, B.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S114 - S115