Automated, high-throughput image calibration for parallel-laser photogrammetry

被引:0
|
作者
Jack L. Richardson
Emily J. Levy
Riddhi Ranjithkumar
Huichun Yang
Eric Monson
Arthur Cronin
Jordi Galbany
Martha M. Robbins
Susan C. Alberts
Mark E. Reeves
Shannon C. McFarlin
机构
[1] The George Washington University,Department of Anthropology, Center for the Advanced Study of Human Paleobiology
[2] Duke University,Department of Biology
[3] Duke University,Pratt School of Engineering
[4] The George Washington University,Department of Computer Science
[5] Science and Engineering Hall,Duke University Libraries
[6] Amazon Web Services,Department of Physics
[7] Identity Service,Department of Clinical Psychology and Psychobiology
[8] Duke University,Department of Evolutionary Anthropology
[9] The George Washington University,undefined
[10] Applied Materials,undefined
[11] University of Barcelona,undefined
[12] Max Planck Institute for Evolutionary Anthropology,undefined
[13] Duke University,undefined
来源
Mammalian Biology | 2022年 / 102卷
关键词
Automation; Baboon; Gorilla; Image processing; Machine learning; Parallel-laser photogrammetry;
D O I
暂无
中图分类号
学科分类号
摘要
Parallel-laser photogrammetry is growing in popularity as a way to collect non-invasive body size data from wild mammals. Despite its many appeals, this method requires researchers to hand-measure (i) the pixel distance between the parallel laser spots (inter-laser distance) to produce a scale within the image, and (ii) the pixel distance between the study subject’s body landmarks (inter-landmark distance). This manual effort is time-consuming and introduces human error: a researcher measuring the same image twice will rarely return the same values both times (resulting in within-observer error), as is also the case when two researchers measure the same image (resulting in between-observer error). Here, we present two independent methods that automate the inter-laser distance measurement of parallel-laser photogrammetry images. One method uses machine learning and image processing techniques in Python, and the other uses image processing techniques in ImageJ. Both of these methods reduce labor and increase precision without sacrificing accuracy. We first introduce the workflow of the two methods. Then, using two parallel-laser datasets of wild mountain gorilla and wild savannah baboon images, we validate the precision of these two automated methods relative to manual measurements and to each other. We also estimate the reduction of variation in final body size estimates in centimeters when adopting these automated methods, as these methods have no human error. Finally, we highlight the strengths of each method, suggest best practices for adopting either of them, and propose future directions for the automation of parallel-laser photogrammetry data.
引用
收藏
页码:615 / 627
页数:12
相关论文
共 50 条
  • [21] Automated diffraction image analysis and spot searching for high-throughput crystal screening
    Zhang, Z
    Sauter, NK
    van den Bedem, H
    Snell, G
    Deacon, AM
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2006, 39 : 112 - 119
  • [22] Automated high-throughput image processing as part of the screening platform for personalized oncology
    Marcel P. Schilling
    Razan El Khaled El Faraj
    Joaquín Eduardo Urrutia Gómez
    Steffen J. Sonnentag
    Fei Wang
    Britta Nestler
    Véronique Orian-Rousseau
    Anna A. Popova
    Pavel A. Levkin
    Markus Reischl
    Scientific Reports, 13
  • [23] Calibration of laryngeal endoscopic high-speed image sequences by an automated detection of parallel laser line projections
    Wurzbacher, Tobias
    Voigt, Ingmar
    Schwarz, Raphael
    Doellinger, Michael
    Hoppe, Ulrich
    Penne, Jochen
    Eysholdt, Ulrich
    Lohscheller, Joerg
    MEDICAL IMAGE ANALYSIS, 2008, 12 (03) : 300 - 317
  • [24] High-throughput investigations on the nitroxide mediated polymerization conditions using an automated parallel synthesizer
    Becer, C. Remzi
    Paulus, Renzo M.
    Hoogenboom, Richard
    Schubert, Ulrich S.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233
  • [25] Automated Cantilever Exchange and Optical Alignment for High-Throughput Parallel Atomic Force Microscopy
    Sadeghian, Hamed
    Bijnagte, Tom
    Herfst, Rodolf
    Kramer, Geerten
    Kramer, Lukas
    Dekker, Bert
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2017, 22 (06) : 2654 - 2661
  • [26] An Automated Infrastructure to Support High-Throughput Bioinformatics
    Cuccuru, Gianmauro
    Leo, Simone
    Lianas, Luca
    Muggiri, Michele
    Pinna, Andrea
    Pireddu, Luca
    Uva, Paolo
    Angius, Andrea
    Fotia, Giorgio
    Zanetti, Gianluigi
    2014 INTERNATIONAL CONFERENCE ON HIGH PERFORMANCE COMPUTING & SIMULATION (HPCS), 2014, : 600 - 607
  • [27] Automated high-throughput DNA synthesis and assembly
    Ma, Yuxin
    Zhang, Zhaoyang
    Jia, Bin
    Yuan, Yingjin
    HELIYON, 2024, 10 (06)
  • [28] Automated, high-throughput serum glycoprofiling platform
    Stoeckmann, H.
    O'Flaherty, R.
    Adamczyk, B.
    Saldova, R.
    Rudd, P. M.
    INTEGRATIVE BIOLOGY, 2015, 7 (09) : 1026 - 1032
  • [29] A high-throughput strategy for protein profiling in cell microarrays using automated image analysis
    Ponten, F.
    Asplund, A.
    Stromberg, S.
    Persson, A.
    Kononen, J.
    Uhlen, M.
    MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (10) : S34 - S34
  • [30] A high-throughput strategy for protein profiling in cell microarrays using automated image analysis
    Stromberg, Sara
    Bjorklund, Marcus Gry
    Asplund, Caroline
    Skollermo, Anna
    Persson, Anja
    Wester, Kenneth
    Kampf, Caroline
    Nilsson, Peter
    Andersson, Ann-Catrin
    Uhlen, Mathias
    Kononen, Juha
    Ponten, Fredrik
    Asplund, Anna
    PROTEOMICS, 2007, 7 (13) : 2142 - 2150