Value of Tc-99m sestamibi scintigraphy in the detection of bone lesions in multiple myeloma: Comparison with Tc-99m methylene diphosphonate

被引:0
|
作者
Alexandrakis M. [1 ]
Kyriakou D. [1 ]
Passam F. [1 ]
Koukouraki S. [2 ]
Karkavitsas N. [2 ]
机构
[1] Department of Hematology, University Hospital of Heraklion, Heraklion, Crete
[2] Department of Nuclear Medicine, University of Crete, University Hospital of Heraklion, Heraklion, Crete
关键词
Multiple myeloma; Tc-99m methylene diphosphate; Tc-99m sestamibi;
D O I
10.1007/s002770100302
中图分类号
学科分类号
摘要
Technetium 99m-2-methoxyisobutylisonitrile (Tc-99m MIBI) is a lipophilic agent that accumulates preferentially within living malignant cells due to the higher transmembrane electrical potential as a consequence of the higher metabolic rate than in the surrounding normal cells. It has been effectively used to detect malignant tumors at diagnosis and follow-up and has been reported to be useful in detecting disease lesions in multiple myeloma. We studied 28 consecutive patients with multiple myeloma at diagnosis to determine the value of Tc-99m MIBI in comparison with Tc-99m methylene diphosphonate (MDP), conventional X-rays, computed tomography (CT) scan, and magnetic resonance imaging (MRI). We found 26 patients with obvious osteolytic lesions in X-rays, 22 patients with positive Tc-99m MIBI scans, and 15 patients with positive Tc-99m MDP scans. There was no coincidence of the positive lesions in the two scans, while in two patients the osteolytic areas were positive in the Tc-99m MDP scans, and in one case the osteolytic area was positive in the Tc-99m MIBI scan. The intensity of Tc-99m MIBI scans correlated with disease activity as determined by lactate dehydrogenase (LDH) (p<0.05), C-reactive protein (CRP) (p<0.01), β2-microglobulin (p<0.05), and serum ferritin (p<0.01). We believe that Tc-99m MIBI scintigraphy can detect bone marrow lesions in myeloma patients that cannot be detected by other imaging methods and that it can be useful especially in solitary myeloma to exclude other involved sites. In addition, it could be a prognostic factor related to disease activity and multidrug resistance. We believe that a multicenter study is needed to evaluate the usefulness of this agent.
引用
收藏
页码:349 / 353
页数:4
相关论文
共 50 条
  • [41] Comparison of Tc-99m THY and Tc-99m MIBI scans for diagnosis of breast lesions
    Gutfilen, B
    da Fonseca, LMB
    JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH, 2001, 20 (03) : 385 - 391
  • [42] Comparison of Tc-99m sestamibi and Tl-201 uptake in multiple myeloma
    Chun, KA
    Cho, IH
    Won, KC
    Lee, KH
    Lee, HW
    Hyun, MS
    Hayashida, K
    CLINICAL NUCLEAR MEDICINE, 2001, 26 (03) : 212 - 215
  • [43] EXPANDED TC-99M METHYLENE DIPHOSPHONATE (MDP) BONE-SCAN
    POLLEN, JJ
    WITZTUM, K
    BASARAB, R
    UROLOGY, 1984, 24 (06) : 632 - 638
  • [44] The comparision of Tc-99m MIBI and Tc-99m MDP scintimammography in detection of breast lesions
    Atalay, M
    Uluc, E
    Polat, M
    Gür, S
    Çökmez, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1119 - 1119
  • [45] TC-99M MDP VS TC-99M DICARBOXYPROPANE DIPHOSPHONATE - A CLINICAL COMPARISON IN VARIOUS PATHOLOGICAL CONDITIONS
    GODART, G
    DUREZ, M
    BEVILACQUA, M
    ABRAMOVICI, J
    ROBIENCE, Y
    CLINICAL NUCLEAR MEDICINE, 1986, 11 (02) : 92 - 97
  • [46] Preoperative detection of parathyroid adenomas with Tc-99m MIBI and Tc-99m pertechnetate scintigraphy: histopathological and biochemical correlation with Tc-99m MIBI uptake
    Akin, Murat
    Atasever, Tamer
    Kurukahvecioglu, Osman
    Dogan, Mehmet
    Gokaslan, Devrim
    Poyraz, Aylar
    Koksal, Hande
    Taneri, Ferit
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2009, 110 (03): : 166 - 169
  • [47] Usefulness of Tc-99m MIBI scintigraphy in patients with multiple myeloma
    Aratani, T
    Narabayashi, I
    Komori, T
    Ogura, Y
    Utsunomiya, K
    Sueyoshi, K
    RADIOLOGY, 2000, 217 : 533 - 533
  • [48] Tl-201, Tc-99m Sestamibi, and Tc-99m HMDP uptake in multiple brown tumors
    Ohnishi, H
    Abe, M
    Miyagawa, M
    Nishimura, K
    CLINICAL NUCLEAR MEDICINE, 2003, 28 (07) : 601 - 603
  • [49] CLINICAL COMPARISON OF TC-99M HEDP AND TC-99M MDP IN THE DETECTION OF BONE METASTASES - CONCISE COMMUNICATION
    FOGELMAN, I
    CITRIN, DL
    MCKILLOP, JH
    TURNER, JG
    BESSENT, RG
    GREIG, WR
    JOURNAL OF NUCLEAR MEDICINE, 1979, 20 (02) : 98 - 101
  • [50] A comparison of the repeat rate in myocardial perfusion imaging between Tc-99m sestamibi and Tc-99m tetrofosmin
    Basso, Danny
    Passmore, Gregory
    Zecchin, Thomas
    Butler, Jayme
    Walters, Gordon
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52