Evaluation of Photopolymerization Kinetics by Means of Transmittance Measurements

被引:0
|
作者
G. Bovesecchi
P. Coppa
E. Armellin
L. Cerroni
机构
[1] University of Rome “Tor Vergata”,Department of Industrial Engineering
[2] University of Rome “Tor Vergata”,Department of Clinical Science and Translational Medicine
来源
关键词
Curing time; Kinetic; Light transmittance; Photodiode; Polymerization; Resin;
D O I
暂无
中图分类号
学科分类号
摘要
Polymeric resins are widely used for dental reconstruction, and most resins use camphorquinone as activator of the polymerization reaction, through the absorption of light at a defined wavelength range (from 400 nm to 460 nm). During the photopolymerization curing, transparency of these resins changes and transmittance variation can be detected by photodiode and bolometer measurements. This change can be used as an index of the reaction rate, and the kinetic parameter k (reaction rate) can be evaluated from transmittance data by means of nonlinear regression. The relation between k and the light intensity impinging on the resin sample can thus be obtained. In the present work, tests were carried out using the resin Enamel Plus HFO GE2. Results reveal the presence of two different polymerization reactions at two different intensity ranges. The obtained k values were used to predict the most suited curing times for different light intensities. The proposed methodology can be applied to different dental reconstruction materials, provided that the material is partially transparent and that its transparency changes during the polymerization reaction.
引用
收藏
相关论文
共 50 条
  • [31] A polymerizable photosensitizer and its photopolymerization kinetics
    Wang, JZ
    Mathias, LJ
    [J]. POLYMER INTERNATIONAL, 2005, 54 (11) : 1537 - 1542
  • [32] Modeling the effect of oxygen on photopolymerization kinetics
    O'Brien, AK
    Bowman, CN
    [J]. MACROMOLECULAR THEORY AND SIMULATIONS, 2006, 15 (02) : 176 - 182
  • [33] Use of bidirectional transmittance distribution function measurements to determine transmittance haze
    Molloy, E.
    Koo, A.
    Gevaux, L.
    Obein, G.
    Yang, L.
    [J]. METROLOGIA, 2023, 60 (05)
  • [34] CONTRIBUTIONS TO EVALUATION OF GRAVIMETRIC MEASUREMENTS BY MEANS OF FREQUENCY ANALYSIS
    MILCOVEANU, D
    [J]. ZEITSCHRIFT FUR ANGEWANDTE GEOLOGIE, 1972, 18 (01): : 25 - +
  • [35] Evaluation of disfluent speech by means of automatic acoustic measurements
    Lustyk, Tomas
    Bergl, Petr
    Cmejla, Roman
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2014, 135 (03): : 1457 - 1468
  • [36] Comparison measurements on regular spectral transmittance
    Manoochehri, F
    Ikonen, E
    Liedquist, L
    [J]. COLOR RESEARCH AND APPLICATION, 1996, 21 (06): : 440 - 447
  • [37] Switched pulsed multiport for transmittance measurements
    Kukier, M
    Michnowski, R
    [J]. MIKON-2000, VOLS 1 & 2, PROCEEDINGS, 2000, : 551 - 554
  • [38] MEASUREMENTS AND CALCULATIONS OF ATMOSPHERIC TRANSMITTANCE AND RADIANCE
    PERSKY, MJ
    WEINBERG, JM
    [J]. OPTICAL ENGINEERING, 1976, 15 (06) : 521 - 524
  • [39] TRANSMITTANCE MEASUREMENTS OF THERMAL IMAGING LENSES
    DEANS, CDP
    JENNINGS, JP
    LEWIS, C
    MCRAE, I
    [J]. PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 467 : 144 - 148
  • [40] USE OF ASYMMETRIC INTERFEROGRAMS IN TRANSMITTANCE MEASUREMENTS
    BELL, EE
    [J]. JOURNAL DE PHYSIQUE, 1967, 28 (3-4S): : 18 - &