Agreement of an inert gas rebreathing device with thermodilution and the direct oxygen fick method in measurement of pulmonary blood flow

被引:58
|
作者
Peyton P.J. [1 ]
Thompson B. [2 ]
机构
[1] Department of Anaesthesia, Austin Hospital, Melbourne, Vic.
[2] Department of Allergy, Immunology and Respiratory Medicine, Monash University, Melbourne, Vic.
关键词
Cardiac output; Effective pulmonary capillary blood flow; Non-invasive; Oxygen uptake; Rebreathing technique;
D O I
10.1007/s10877-005-1589-6
中图分类号
学科分类号
摘要
Objective. Inert gas rebreathing is a well established method for the non-invasive measurement of pulmonary blood flow. We tested the agreement in measurement of pulmonary blood flow (Qt rb) by a new inert soluble gas rebreathing device, the Innocor (Innovision, Copenhagen), with bolus thermodilution (Qt td) and the direct oxygen Fick (Qt Fick) method. Methods. 9 patients pre- and post-cardiac surgery were recruited resulting in 20 sets of measurements overall. Arterial and mixed venous blood samples were collected simultaneously with a thermodilution measurement and rebreathing manoeuvre to measure both VO2 and effective pulmonary capillary blood flow. Results. Mean bias (95% confidence limits) was: Qt rb - Qt td 0.01 (± 0.42) L/min; Qt rb - Qt Fick + 0.34 (± 0.59) L/min. The standard deviation of the difference between paired measurements was: Qt td - Qt rb ± 0.89 L/min; Qt Fick - Qt rb ± 1.26 L/min. Conclusions. Acceptable overall agreement between the Innocor and these reference standards was demonstrated. © Springer Science + Business Media, Inc. 2005.
引用
收藏
页码:373 / 378
页数:5
相关论文
共 50 条
  • [41] MEASUREMENT OF CORONARY BLOOD-FLOW BY THE INERT-GAS METHOD - COMPARISON OF INDICATOR GASES
    WOLPERS, HG
    BOCK, J
    HOEFT, A
    KORB, H
    HELLIGE, G
    ZEITSCHRIFT FUR KARDIOLOGIE, 1987, 76 (02): : 95 - 101
  • [42] NONINVASIVE ESTIMATION OF PULMONARY VASCULAR-RESISTANCE BY STROKE INDEX MEASUREMENT WITH AN INERT-GAS REBREATHING TECHNIQUE
    DURKIN, RJ
    EVANS, TW
    WINTER, SM
    CHEST, 1994, 106 (01) : 59 - 66
  • [43] Clinical applicability of a rebreathing method for noninvasive estimation of effective pulmonary blood flow
    Christensen, P
    Clemensen, P
    Andersen, PK
    9TH EUROPEAN CONGRESS ON INTENSIVE CARE MEDICINE, 1996, : 525 - 528
  • [44] Continuous thermodilution- a novel method for direct measurement of coronary flow and resistance
    Kala, Petr
    Adlova, Radka
    Gasparkova, Veronika
    Ostadal, Petr
    Hajek, Petr
    COR ET VASA, 2025, 67 (01) : 35 - 42
  • [45] MEASUREMENT OF PULMONARY CAPILLARY BLOOD-FLOW BY A NITROUS-OXIDE REBREATHING TECHNIQUE
    STOKKE, T
    BURCHARDI, H
    ANGERER, H
    HENSEL, I
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1986, 30 (07) : 496 - 501
  • [46] Bedside pulmonary blood flow measurement via partial CO2 rebreathing
    de Abreu, MG
    Albrecht, DM
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 1998, 33 : S22 - S23
  • [47] Inert gas rebreathing: the effect of pulmonary shunt flow correction on the accuracy of cardiac output measurements in clinical practice
    Trinkmann, F.
    Papavassiliu, T.
    Kraus, F.
    Leweling, H.
    Schoenberg, S. O.
    Borggrefe, M.
    Kaden, J. J.
    Saur, J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 571 - 571
  • [49] SINGLE-BREATH BREATH HOLDING MEASUREMENT OF PULMONARY BLOOD-FLOW - COMPARISON TO DIRECT FICK CARDIAC-OUTPUT
    KENDRICK, AH
    ROZKOVEC, A
    PAPOUCHADO, M
    WEST, J
    REES, JR
    LASZLO, G
    CLINICAL SCIENCE, 1986, 71 : P36 - P36
  • [50] HEPATIC BLOOD-FLOW MEASUREMENT WITH INERT-GAS CLEARANCE
    MATHIE, RT
    JOURNAL OF SURGICAL RESEARCH, 1986, 41 (01) : 92 - 110