Agreement of an inert gas rebreathing device with thermodilution and the direct oxygen fick method in measurement of pulmonary blood flow

被引:58
|
作者
Peyton P.J. [1 ]
Thompson B. [2 ]
机构
[1] Department of Anaesthesia, Austin Hospital, Melbourne, Vic.
[2] Department of Allergy, Immunology and Respiratory Medicine, Monash University, Melbourne, Vic.
关键词
Cardiac output; Effective pulmonary capillary blood flow; Non-invasive; Oxygen uptake; Rebreathing technique;
D O I
10.1007/s10877-005-1589-6
中图分类号
学科分类号
摘要
Objective. Inert gas rebreathing is a well established method for the non-invasive measurement of pulmonary blood flow. We tested the agreement in measurement of pulmonary blood flow (Qt rb) by a new inert soluble gas rebreathing device, the Innocor (Innovision, Copenhagen), with bolus thermodilution (Qt td) and the direct oxygen Fick (Qt Fick) method. Methods. 9 patients pre- and post-cardiac surgery were recruited resulting in 20 sets of measurements overall. Arterial and mixed venous blood samples were collected simultaneously with a thermodilution measurement and rebreathing manoeuvre to measure both VO2 and effective pulmonary capillary blood flow. Results. Mean bias (95% confidence limits) was: Qt rb - Qt td 0.01 (± 0.42) L/min; Qt rb - Qt Fick + 0.34 (± 0.59) L/min. The standard deviation of the difference between paired measurements was: Qt td - Qt rb ± 0.89 L/min; Qt Fick - Qt rb ± 1.26 L/min. Conclusions. Acceptable overall agreement between the Innocor and these reference standards was demonstrated. © Springer Science + Business Media, Inc. 2005.
引用
收藏
页码:373 / 378
页数:5
相关论文
共 50 条
  • [1] Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow
    Christensen, P
    Clemensen, P
    Andersen, PK
    Henneberg, SW
    CRITICAL CARE MEDICINE, 2000, 28 (01) : 51 - 56
  • [2] Determination of cardiac output by the Fick method, thermodilution, and acetylene rebreathing in pulmonary hypertension
    Hoeper, MM
    Maier, R
    Tongers, J
    Niedermeyer, J
    Hohlfeld, JM
    Hamm, M
    Fabel, H
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (02) : 535 - 541
  • [3] Non-invasive assessment of pulmonary blood flow using an inert gas rebreathing device in patients with pulmonary hypertension
    Mclure, L. E. R.
    Brown, A.
    Peacock, A.
    Johnson, M. K.
    THORAX, 2007, 62 : A17 - A17
  • [4] COMPARISON OF CARDIAC-OUTPUT MEASUREMENT TECHNIQUES - THERMODILUTION, DOPPLER, CO2-REBREATHING AND THE DIRECT FICK METHOD
    ESPERSEN, K
    JENSEN, EW
    ROSENBORG, D
    THOMSEN, JK
    ELIASEN, K
    OLSEN, NV
    KANSTRUP, IL
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 (02) : 245 - 251
  • [5] EFFECT OF INSPIRED OXYGEN CONCENTRATION ON EFFECTIVE PULMONARY BLOOD-FLOW MEASURED BY AN INERT-GAS REBREATHING METHOD IN VENTILATED PATIENTS
    TREACHER, DF
    COWELL, TK
    BRADLEY, RD
    THORAX, 1986, 41 (09) : 725 - 725
  • [6] MEASUREMENT OF EFFECTIVE PULMONARY CAPILLARY BLOOD-FLOW (QEP) - COMPARISON OF REBREATHING AND THERMODILUTION TECHNIQUES
    TRUEMPER, EJ
    BRUDNO, DS
    LUTIN, WA
    STEINHART, CM
    CUTLIFFE, S
    PEDIATRIC RESEARCH, 1995, 37 (04) : A56 - A56
  • [7] Non-invasive assessment of pulmonary blood flow using an inert gas rebreathing device in fibrotic lung disease
    Corte, Tamera J.
    Wells, Athol U.
    Gatzoulis, Michael A.
    Cramer, Derek
    Ward, Simon
    Macdonald, Peter S.
    Dimopoulos, Konstantinos
    Wort, Stephen J.
    THORAX, 2010, 65 (04) : 341 - 345
  • [8] The Impact of Pulmonary Disease on Noninvasive Measurement of Cardiac Output by the Inert Gas Rebreathing Method
    Joachim Saur
    Frederik Trinkmann
    Christina Doesch
    Armin Scherhag
    Joachim Brade
    Stefan O. Schoenberg
    Martin Borggrefe
    Jens J. Kaden
    Theano Papavassiliu
    Lung, 2010, 188 : 433 - 440
  • [9] The Impact of Pulmonary Disease on Noninvasive Measurement of Cardiac Output by the Inert Gas Rebreathing Method
    Saur, Joachim
    Trinkmann, Frederik
    Doesch, Christina
    Scherhag, Armin
    Brade, Joachim
    Schoenberg, Stefan O.
    Borggrefe, Martin
    Kaden, Jens J.
    Papavassiliu, Theano
    LUNG, 2010, 188 (05) : 433 - 440
  • [10] MEASUREMENT OF CARDIAC-OUTPUT BY THERMODILUTION - CORRELATION WITH DIRECT FICK METHOD
    BAEZA, H
    CHAMORRO, G
    LANAS, F
    ESCOBAR, E