Agarose coated micro-bottle sensor for relative humidity detection

被引:0
|
作者
Huda Adnan Zain
Malathy Batumalay
Md Ashadi Md Johari
Kaharudin Dimyati
Sulaiman Wadi Harun
机构
[1] University of Malaya,Department of Electrical Physics
[2] INTI International University,Faculty of Information Technology
[3] Universiti Teknikal Malaysia Melaka,Faculty of Electrical and Electronic Engineering Technology
[4] Airlangga University,Department of Physics, Faculty of Science and Technology
来源
Optoelectronics Letters | 2021年 / 17卷
关键词
A;
D O I
暂无
中图分类号
学科分类号
摘要
The whispering gallery mode (WGM) based micro-bottle resonator (MBR) sensor has been proposed and demonstrated for relative humidity measurement by using an agarose gel as a transducer. MBR was fabricated by using a soften-and-compress method to form a 190 µm bulge bottle. The micro-bottle was optically excited by a 3 µm tapered fiber and it exhibits a resonance with a Q factor in an order of 105. The agarose coated MBR produces a good sensing response towards humidity with the sensitivity of 0.107 dB/%RH and linearity of 99.614%. The agarose hydrophilic nature and its changing porosity and refractive index with increasing relative humidity made the coated MBR structure to be more sensitive than the uncoated structure. This humidity sensor has a simple fabrication and is showing good sensitivity, linearity, resolution, response time and operational in a wide humidity range.
引用
收藏
页码:328 / 333
页数:5
相关论文
共 50 条
  • [31] Relative Humidity Sensor Based on an Agarose-Infiltrated Photonic Crystal Fiber Interferometer
    Mathew, Jinesh
    Semenova, Yuliya
    Farrell, Gerald
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2012, 18 (05) : 1553 - 1559
  • [32] Agarose gel-coated LPG based on two sensing mechanisms for relative humidity measurement
    Miao, Yinping
    Zhang, Kaikiang
    Yuam, Yujie
    Liu, Bo
    Zhang, Hao
    Liu, Yan
    Yao, Jianquan
    APPLIED OPTICS, 2013, 52 (01) : 90 - 95
  • [33] HEC/PVDF coated microbottle resonators for relative humidity detection
    Zain, H. A.
    Batumalay, M.
    Rahim, H. R. A.
    Yasin, M.
    Harun, S. W.
    OPTIK, 2021, 232
  • [34] LPG-based PVA coated sensor for relative humidity measurement
    Venugopalan, T.
    Yeo, Teck L.
    Sun, Tong
    Grattan, Kenneth T. V.
    IEEE SENSORS JOURNAL, 2008, 8 (7-8) : 1093 - 1098
  • [35] High sensitivity relative humidity sensor based onSMTFstructure coated with gelatin
    Guo, Jiachen
    Bo, Jia
    Tang, Huang
    Zhao, Dong
    Zhou, Pengwei
    Wang, Jian
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2020, 62 (11) : 3432 - 3437
  • [36] A relative humidity sensor using a hydrogel-coated long period grating
    Wang, Liwei
    Liu, Yang
    Zhang, Min
    Tu, Dongsheng
    Mao, Xianhui
    Liao, Yanbiao
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (10) : 3131 - 3134
  • [37] RELATIVE-HUMIDITY MEASUREMENTS USING A COATED PIEZOELECTRIC QUARTZ CRYSTAL SENSOR
    RANDIN, JP
    ZULLIG, F
    SENSORS AND ACTUATORS, 1987, 11 (04): : 319 - 328
  • [38] A fast response and highly sensitivity relative humidity sensor with polymer-coated micro-nano fiber Bragg grating
    Li, Pengfei
    Yan, Haitao
    Zhang, Feilin
    Cao, Hongzhan
    Xie, Zhanwu
    FIBER OPTIC SENSING AND OPTICAL COMMUNICATION, 2018, 10849
  • [39] Ultralow sensing limit in optofluidic micro-bottle resonator biosensor by self-referenced differential-mode detection scheme
    Zhang, Xingwang
    Liu, Liying
    Xu, Lei
    APPLIED PHYSICS LETTERS, 2014, 104 (03)
  • [40] Effect of coating thickness on the sensitivity of a humidity sensor based on an Agarose coated photonic crystal fiber interferometer
    Mathew, Jinesh
    Semenova, Yuliya
    Farrell, Gerald
    OPTICS EXPRESS, 2013, 21 (05): : 6313 - 6320