Quantitative Analysis of a Whole Cardiac Mass Using Dual-Energy Computed Tomography: Comparison with Conventional Computed Tomography and Magnetic Resonance Imaging

被引:0
|
作者
Yoo Jin Hong
Jin Hur
Kyunghwa Han
Dong Jin Im
Young Joo Suh
Hye-Jeong Lee
Young Jin Kim
Byoung Wook Choi
机构
[1] Yonsei University College of Medicine,Department of Radiology and Research Institute of Radiological Science
[2] Severance Hospital,undefined
来源
关键词
Cardiac Mass; Cardiac Tumors; Mean Iodine Concentration; Thrombus Group; Late Gadolinium Enhancement (LGE);
D O I
暂无
中图分类号
学科分类号
摘要
It is critical to distinguish between cardiac tumors and thrombi because they require different treatment strategies. Although accurate differentiation of these cardiac masses can be challenging, computed tomography (CT) and magnetic resonance imaging (MRI) are promising tools to improve their diagnosis. This study aimed to assess the diagnostic value of a volume-based quantification strategy using dual-energy CT to differentiate between cardiac tumors and thrombi. We prospectively enrolled 41 patients who had a cardiac mass. All patients underwent electrocardiography gated dual-energy CT. Among them, 28 patients underwent late gadolinium enhancement cardiac MRI. For quantitative analysis, the following parameters of the entire cardiac masses were measured: CT attenuation values in Hounsfield units (HU), iodine concentration (mg/ml), and signal intensity (SI) ratio. A mixed effects model was used to evaluate the significance of differences in mean CT attenuation, mean iodine concentration, and SI ratios between the cardiac tumor and thrombus groups. Diagnostic performance of each parameter was evaluated by constructing a receiver operating characteristics curve. A total of 24 cardiac tumors and 19 cardiac thrombi were analyzed. The mean iodine concentration was significantly higher in tumors than in thrombi (tumors: 2.98 ± 0.23; thrombi: 1.79 ± 0.26, p = 0.002). The diagnostic performance of iodine concentration was better than that of post-contrast HU (area under the curve [AUC]: 0.77 vs. 0.51; p < 0.001), and worse than that of SI ratio (AUC: 0.89; p = 0.04) for differentiation of cardiac tumors and thrombi. Dual-energy CT using volume-based iodine measurements can differentiate between cardiac tumors and thrombi.
引用
收藏
相关论文
共 50 条
  • [31] Correlation of Quantitative Dual-Energy Computed Tomography Iodine Maps and Abdominal Computed Tomography Perfusion Measurements Are Single-Acquisition Dual-Energy Computed Tomography Iodine Maps More Than a Reduced-Dose Surrogate of Conventional Computed Tomography Perfusion?
    Stiller, Wolfram
    Skornitzke, Stephan
    Fritz, Franziska
    Klauss, Miriam
    Hansen, Jens
    Pahn, Gregor
    Grenacher, Lars
    Kauczor, Hans-Ulrich
    INVESTIGATIVE RADIOLOGY, 2015, 50 (10) : 703 - 708
  • [32] Quantification of pancreas fat on dual-energy computed tomography: comparison with six-point Dixon magnetic resonance imaging
    Kameda, Fumi
    Tanabe, Masahiro
    Onoda, Hideko
    Higashi, Mayumi
    Ariyoshi, Shoko
    Ihara, Kenichiro
    Lida, Etsushi
    Furukawa, Matakazu
    Okada, Munemasa
    Ito, Katsuyoshi
    ABDOMINAL RADIOLOGY, 2020, 45 (09) : 2779 - 2785
  • [33] Quantification of pancreas fat on dual-energy computed tomography: comparison with six-point Dixon magnetic resonance imaging
    Fumi Kameda
    Masahiro Tanabe
    Hideko Onoda
    Mayumi Higashi
    Shoko Ariyoshi
    Kenichiro Ihara
    Etsushi Iida
    Matakazu Furukawa
    Munemasa Okada
    Katsuyoshi Ito
    Abdominal Radiology, 2020, 45 : 2779 - 2785
  • [34] Feasibility of computed tomography texture analysis of hepatic fibrosis using dual-energy spectral detector computed tomography
    Choi, ByukGyung
    Choi, In Young
    Cha, Sang Hoon
    Yeom, Suk Keu
    Chung, Hwan Hoon
    Lee, Seung Hwa
    Cha, Jaehyung
    Lee, Ju-Han
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (12) : 1179 - 1189
  • [35] Feasibility of computed tomography texture analysis of hepatic fibrosis using dual-energy spectral detector computed tomography
    ByukGyung Choi
    In Young Choi
    Sang Hoon Cha
    Suk Keu Yeom
    Hwan Hoon Chung
    Seung Hwa Lee
    Jaehyung Cha
    Ju-Han Lee
    Japanese Journal of Radiology, 2020, 38 : 1179 - 1189
  • [36] Quantification of Hepatic Steatosis With Dual-Energy Computed Tomography Comparison With Tissue Reference Standards and Quantitative Magnetic Resonance Imaging in the ob/ob Mouse
    Artz, Nathan S.
    Hines, Catherine D. G.
    Brunner, Stephen T.
    Agni, Rashmi M.
    Kuehn, Jens-Peter
    Roldan-Alzate, Alejandro
    Chen, Guang-Hong
    Reeder, Scott B.
    INVESTIGATIVE RADIOLOGY, 2012, 47 (10) : 603 - 610
  • [37] Single source dual-energy computed tomography in the diagnosis of gout: Diagnostic reliability in comparison to digital radiography and conventional computed tomography of the feet
    Kiefer, Tobias
    Diekhoff, Torsten
    Hermann, Sandra
    Stroux, Andrea
    Mews, Jurgen
    Blobel, Jorg
    Hamm, Bernd
    Hermann, Kay-Geert A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1829 - 1834
  • [38] Quantitative material analysis by dual-energy computed tomography for industrial NDT applications
    Nachtrab, F.
    Weis, S.
    Kessling, P.
    Sukowski, F.
    Hassler, U.
    Fuchs, T.
    Uhlmann, N.
    Hanke, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S159 - S162
  • [39] A quantitative comparison of the capabilities of in situ computed tomography and conventional computed tomography for damage analysis of composites
    Boehm, R.
    Stiller, J.
    Behnisch, T.
    Zscheyge, M.
    Protz, R.
    Radloff, S.
    Gude, M.
    Hufenbach, W.
    COMPOSITES SCIENCE AND TECHNOLOGY, 2015, 110 : 62 - 68
  • [40] Gastrointestinal Imaging: Emerging Role of Dual-Energy Computed Tomography
    Ali I.T.
    Thomas C.
    Elbanna K.Y.
    Mohammed M.F.
    Berger F.H.
    Khosa F.
    Current Radiology Reports, 5 (8)