Elastomeric seismic-protection isolators for buildings and bridges

被引:0
|
作者
Toshio Nishi
Nobuo Murota
机构
[1] Tokyo Institute of Technology,International Division
[2] Department of Seismic Isolation & Vibration Control Development,undefined
来源
关键词
Elastomeric isolator; Seismic isolation; Rubber bearing;
D O I
暂无
中图分类号
学科分类号
摘要
A giant earthquake of magnitude 9.0 occurred in Pacific Ocean off of Tohoku District Japan on March 11, 2011. The highest seismic intensity of 7 in JMA scale was recorded in Miyagi. In the Tohoku district, around 230 buildings are seismically isolated (hereafter, SI) mainly by elastomeric isolators (seismic rubber bearings). According to the official survey reports by several organizations (for example[1]), the records of those buildings have verified the effectiveness of the seismic isolation. The response acceleration of the SI buildings was reduced by 30% to 50% of the input ground acceleration. Additionally, the difference of the conditions inside the room between SI and the fixed-base buildings was obvious as well as the damage in main structures of the buildings. The displacements of the isolators by the earthquake were around 200 mm according to the records of the instruments. As a result, the performance of SI buildings and the elastomeric isolators in the Tohoku District — Off the Pacific Ocean Earthquake 2011 were excellent, and the efficiency of the seismic isolation was verified by the records of many buildings in wide area.
引用
收藏
页码:50 / 57
页数:7
相关论文
共 50 条
  • [21] Performance of elastomeric seismic isolators under long-period earthquakes
    Abrar, O.
    Tuhta, S.
    MAGAZINE OF CIVIL ENGINEERING, 2022, 110 (02):
  • [22] Studying the standard's requirements for elastomeric seismic isolators by virtual testing
    Blostotsky, Boris
    Efraim, Elia
    COMPUTER APPLICATIONS IN ENGINEERING EDUCATION, 2015, 23 (04) : 556 - 566
  • [23] Erratum to: Effects of air temperature on the cyclic behavior of elastomeric seismic isolators
    Donatello Cardone
    Giuseppe Gesualdi
    Domenico Nigro
    Bulletin of Earthquake Engineering, 2011, 9 (4) : 1257 - 1257
  • [24] Using Wire Rope Isolators for Seismic Protection
    Prost, Claude
    Partyka, Joshua
    SOUND AND VIBRATION, 2016, 50 (05): : 8 - 11
  • [25] Seismic rehabilitation of cultural heritage masonry buildings with unbonded fiber reinforced elastomeric isolators (U-FREIs) - A case of study
    Pauletta, Margherita
    Di Luca, Daniele
    Russo, Eleonora
    Fumo, Cristina
    JOURNAL OF CULTURAL HERITAGE, 2018, 32 : 84 - 97
  • [26] Earthquake response control of hospital buildings using unbonded fibrereinforced elastomeric isolators
    Banerjee, Sarranya
    Matsagar, Vasant A.
    SUSTAINABLE AND RESILIENT INFRASTRUCTURE, 2023, 8 : 85 - 92
  • [27] Impact of the Implementation of Unbonded Seismic Isolators on the Design and Retrofitting of Bridges
    Restrepo, Manuela Gomez
    Sierra, Ingrid Madera E.
    Castellanos-Toro, Sebastian
    Marulanda, Johannio
    STRUCTURAL ENGINEERING INTERNATIONAL, 2023, 33 (04) : 677 - 688
  • [28] Effect of elastomeric bearings on seismic response of skewed bridges
    Maleki, S
    COMPUTATIONAL CIVIL AND STRUCTURAL ENGINEERING, 2000, : 177 - 182
  • [29] Seismic isolation of bridges using elastomeric isolation systems
    Mayes, RL
    BUILDING AN INTERNATIONAL COMMUNITY OF STRUCTURAL ENGINEERS, VOLS 1 AND 2, 1996, : 33 - 40
  • [30] Development of adaptive seismic isolators for ultimate seismic protection of civil structures
    Li, Jianchun
    Li, Yancheng
    Li, Weihua
    Samali, Bijan
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2013, 2013, 8692