Comparison of a hydrophilic and a hydrophobic apodized diffractive multifocal intraocular lens

被引:0
|
作者
Jan Willem van der Linden
Ivanka J. van der Meulen
Maarten P. Mourits
Ruth Lapid-Gortzak
机构
[1] Academic Medical Center,Department of Ophthalmology
[2] University of Amsterdam,undefined
[3] Retina Total Eye Care,undefined
来源
关键词
Anterior Chamber Depth; Corrected Distance Visual Acuity; Posterior Capsular Opacification; Uncorrected Distance Visual Acuity; Diffractive Lens;
D O I
暂无
中图分类号
学科分类号
摘要
To compare outcomes between a new design apodized diffractive hydrophilic multifocal intraocular lens (IOL) (Seelens MF; study group), and a well-known apodized diffractive hydrophobic multifocal IOL (SN6AD1; control group). A comparative case series comparing refractive and visual outcomes at distance and near. Patient satisfaction with a validated questionnaire, dysphotopsia and straylight measurement scores were recorded at 3 months post-operatively. The study group comprised 48 eyes and the control group 37 eyes. At 3 months post-operatively the mean uncorrected distance visual acuity (UDVA) was not statistically significant different between the study group and the control group (0.02 ± 0.07 logMAR [SD] vs 0.04 ± 0.09 logMAR). Corrected distance visual acuity (CDVA) was statistically significantly better with the study lens (−0.04 ± 0.05 logMAR vs −0.01 ± 0.04 logMAR (p < 0.019). There was no clinical or statistical significant difference at the 40 cm distance (0.09 ± 0.12 logMAR vs 0.08 ± 0.09 logMAR). The study group had statistically significant better uncorrected near acuity at 50 and 60 cm distances (p < 0.03 and p < 0.007, respectively). In terms of satisfaction the lenses performed equally. Halos were seen less often with the study lens. Straylight, as a parameter for visual quality, was significantly less with the study lens. Conclusion: The Seelens MF performs equally as well as the well-known SN6AD1 for UCDA and CDVA. The Seelens MF performs better at intermediate distance, and seems to allow for better depth of focus, and increased visual quality. More study is needed to corroborate the last finding.
引用
收藏
页码:493 / 500
页数:7
相关论文
共 50 条
  • [1] Comparison of a hydrophilic and a hydrophobic apodized diffractive multifocal intraocular lens
    van der Linden, Jan Willem
    van der Meulen, Ivanka J.
    Mourits, Maarten P.
    Lapid-Gortzak, Ruth
    INTERNATIONAL OPHTHALMOLOGY, 2013, 33 (05) : 493 - 500
  • [2] Comparison of a new-generation sectorial addition multifocal intraocular lens and a diffractive apodized multifocal intraocular lens
    van der Linden, Jan Willem
    van Velthoven, Mirjam
    van der Meulen, Ivanka
    Nieuwendaal, Carla
    Mourits, Maarten
    Lapid-Gortzak, Ruth
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (01): : 68 - 73
  • [3] Clear lens extraction with multifocal apodized diffractive intraocular lens implantation
    Fernandez-Vega, Luis
    Alfonso, Jose F.
    Rodriguez, Pedro P.
    Montes-Mico, Robert
    OPHTHALMOLOGY, 2007, 114 (08) : 1491 - 1498
  • [4] Comparative Analysis of Visual Performance and Optical Quality with a Rotationally Asymmetric Multifocal Intraocular Lens and an Apodized Diffractive Multifocal Intraocular Lens
    Wang, Xiao
    Tu, Haixia
    Wang, Yong
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [5] Five-year postoperative outcomes of apodized diffractive multifocal intraocular lens implantation
    Mami Yoshino
    Hiroko Bissen-Miyajima
    Keiichiro Minami
    Yoko Taira
    Japanese Journal of Ophthalmology, 2013, 57 : 510 - 513
  • [6] Five-year postoperative outcomes of apodized diffractive multifocal intraocular lens implantation
    Yoshino, Mami
    Bissen-Miyajima, Hiroko
    Minami, Keiichiro
    Taira, Yoko
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2013, 57 (06) : 510 - 513
  • [7] History and development of the apodized diffractive intraocular lens
    Davison, James A.
    Simpson, Michael J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05): : 849 - 858
  • [8] Energy balance in apodized diffractive multifocal intraocular lenses
    Alba-Bueno, Francisco
    Vega, Fidel
    Millan, Maria S.
    22ND CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: LIGHT FOR THE DEVELOPMENT OF THE WORLD, 2011, 8011
  • [9] Comparison of visual outcomes after implantation of diffractive trifocal toric intraocular lens and a diffractive apodized bifocal toric intraocular lens
    Gundersen, Kjell Gunnar
    Potvin, Rick
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 455 - 461
  • [10] Secondary opacification of a hydrophilic acrylic multifocal intraocular lens with a hydrophobic surface
    Gambrelle, J.
    Robinet, A.
    Le Loir, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2015, 38 (02): : E27 - E28