Reproducibility of volumetric intravascular ultrasound radiofrequency-based analysis of coronary plaque composition in vivo

被引:0
|
作者
Marc Hartmann
Eline S. K. Mattern
Jennifer Huisman
Gert K. van Houwelingen
Frits H. A. F. de Man
Martin G. Stoel
Peter W. Danse
Hans W. Louwerenburg
Clemens von Birgelen
机构
[1] Thoraxcentrum Twente,Department of Cardiology
[2] Medisch Spectrum Twente,Institute for Biomedical Technology (BMTI)
[3] University of Twente,undefined
关键词
Coronary disease; Ultrasonics; Radiofrequency; Virtual histology;
D O I
暂无
中图分类号
学科分类号
摘要
Intravascular ultrasound radiofrequency (RF-IVUS) data permit the analysis of coronary plaque composition in vivo and is used as an endpoint of ongoing pharmacological intervention trials. We assessed the reproducibility of volumetric RF-IVUS analyses in mild-to-moderately diseased atherosclerotic human coronary arteries in vivo. A total of 9,212 IVUS analyses on cross-sectional IVUS frames was performed to evaluate the reproducibility of volumetric RF-IVUS measurements in 33 coronary segments with a length of 27 ± 7 mm. For vessel, lumen, and plaque + media volume the relative measurement differences (P = NS for all) were (A = intraobserver comparison, same pullback) −0.40 ± 1.0%; −0.48 ± 1.4%; −0.35 ± 1.6%, (B = intraobserver comparison, repeated pullback) −0.42 ± 1.2%; −0.52 ± 1.8%; −0.43 ± 4.5% (C = interobserver comparison, same pullback) 0.71 ± 1.8%; 0.71 ± 2.2%, and 0.89 ± 5.0%, respectively. For fibrous, fibro-lipidic, calcium, and necrotic-core volumes the relative measurement differences (P = NS for all) were (A) 0.45 ± 2.1%; −1.12 ± 4.9%; −0.84 ± 2.1%; −0.22 ± 1.8%, (B) 1.40 ± 4.1%; 1.26 ± 6.7%; 2.66 ± 7.4%; 0.85 ± 4.4%, and (C) −1.60 ± 4.9%; 3.85 ± 8.2%; 1.66 ± 7.5%, and −1.58 ± 4.7%, respectively. Of note, necrotic-core volume showed on average the lowest measurement variability. Thus, in mild-to-moderate atherosclerotic coronary artery disease the reproducibility of volumetric compositional RF-IVUS measurements from the same pullback is relatively high, but lower than the reproducibility of geometrical IVUS measurements. Measurements from repeated pullbacks and by different observers show acceptable reproducibilities; the volumetric measurement of the necrotic-core shows on average the highest reproducibility of the compositional RF-IVUS measurements
引用
收藏
页码:13 / 23
页数:10
相关论文
共 50 条
  • [1] Reproducibility of volumetric intravascular ultrasound radiofrequency-based analysis of coronary plaque composition in vivo
    Hartmann, Marc
    Mattern, Eline S. K.
    Huisman, Jennifer
    van Houwelingen, Gert K.
    de Man, Frits H. A. F.
    Stoel, Martin G.
    Danse, Peter W.
    Louwerenburg, Hans W.
    von Birgelen, Clemens
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (01): : 13 - 23
  • [2] Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented
    Jennifer Huisman
    Rasmus Egede
    Adam Rdzanek
    Dirk Böse
    Raimund Erbel
    Janusz Kochman
    Lisette Okkels Jensen
    Job van der Palen
    Marc Hartmann
    Gary S. Mintz
    Clemens von Birgelen
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1867 - 1878
  • [3] Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented
    Huisman, Jennifer
    Egede, Rasmus
    Rdzanek, Adam
    Boese, Dirk
    Erbel, Raimund
    Kochman, Janusz
    Jensen, Lisette Okkels
    van der Palen, Job
    Hartmann, Marc
    Mintz, Gary S.
    von Birgelen, Clemens
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08): : 1867 - 1878
  • [4] European multicenter study on the between-center reproducibility of volumetric radiofrequency-based intravascular ultrasound analyses in coronary lesions prior to stenting
    Huisman, J.
    Egede, R.
    Rdzanek, A.
    Boese, D.
    Erbel, R.
    Kochman, J.
    Jensen, L. O.
    Hartmann, M.
    Mintz, G. S.
    Von Birgelen, C.
    EUROPEAN HEART JOURNAL, 2011, 32 : 862 - 862
  • [5] Relation of plaque size to compositions as determined by an in vivo volumetric intravascular ultrasound radiofrequency analysis
    Ze-Sheng Xu
    Byoung Kwon Lee
    Duk-Woo Park
    Seung-Whan Lee
    Young-Hak Kim
    Cheol Whan Lee
    Myeong-Ki Hong
    The International Journal of Cardiovascular Imaging, 2010, 26 : 165 - 171
  • [6] Relation of plaque size to compositions as determined by an in vivo volumetric intravascular ultrasound radiofrequency analysis
    Xu, Ze-Sheng
    Lee, Byoung Kwon
    Park, Duk-Woo
    Lee, Seung-Whan
    Kim, Young-Hak
    Lee, Cheol Whan
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (02): : 165 - 171
  • [7] Relation of plaque size to compositions as determined by an in vivo volumetric intravascular ultrasound radiofrequency analysis
    Hong, Myeong-Ki
    Park, Chang-Bum
    Lee, Cheol Whan
    Park, Duk-Woo
    Kim, Won-Jang
    Park, Jong-Pil
    Lee, Jeong-Woo
    Park, Jae Hyoung
    Kim, Gyung-Jung
    Lee, Seung-Whan
    Kim, Young-Hak
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : B25 - B25
  • [8] Between-centre reproducibility of volumetric intravascular ultrasound radiofrequency-based analyses in mild-to-moderate coronary atherosclerosis: an international multicentre study
    Huisman, Jennifer
    Egede, Rasmus
    Rdzanek, Adam
    Boese, Dirk
    Erbel, Raimund
    Kochman, Janusz
    Jensen, Lisette Okkels
    van de Palen, Job
    Hartmann, Marc
    Mintz, Gary S.
    von Birgelen, Clemens
    EUROINTERVENTION, 2010, 5 (08) : 925 - 931
  • [9] Impact of coronary plaque composition on preinfarction angina; intravascular ultrasound radiofrequency analysis
    Higashikuni, Y.
    Tanabe, K.
    Aoki, J.
    Nakajima, H.
    Nakazawa, G.
    Onuma, Y.
    Yamamoto, H.
    Hara, K.
    EUROPEAN HEART JOURNAL, 2006, 27 : 365 - 366
  • [10] Statin treatment for coronary artery plaque composition based on intravascular ultrasound radiofrequency data analysis
    Nozue, Tsuyoshi
    Yamamoto, Shingo
    Tohyama, Shinichi
    Umezawa, Shigeo
    Kunishima, Tomoyuki
    Sato, Akira
    Miyake, Shogo
    Takeyama, Youichi
    Morino, Yoshihiro
    Yamauchi, Takao
    Muramatsu, Toshiya
    Hibi, Kiyoshi
    Sozu, Takashi
    Terashima, Mitsuyasu
    Michishita, Ichiro
    AMERICAN HEART JOURNAL, 2012, 163 (02) : 191 - U285