Between-centre reproducibility of volumetric intravascular ultrasound radiofrequency-based analyses in mild-to-moderate coronary atherosclerosis: an international multicentre study

被引:0
|
作者
Huisman, Jennifer [1 ]
Egede, Rasmus [2 ]
Rdzanek, Adam [3 ]
Boese, Dirk [4 ]
Erbel, Raimund [4 ]
Kochman, Janusz [3 ]
Jensen, Lisette Okkels [2 ]
van de Palen, Job [5 ,6 ]
Hartmann, Marc [1 ]
Mintz, Gary S. [7 ]
von Birgelen, Clemens [1 ,8 ]
机构
[1] Med Spectrum Twente, Thoraxctr Twente, Dept Cardiol, NL-7513 ER Enschede, Netherlands
[2] Odense Univ Hosp, Dept Cardiol, DK-5000 Odense, Denmark
[3] Cent Univ Hosp, Dept Cardiol, Warsaw, Poland
[4] Univ Klinikum Essen Duisburg, Dept Cardiol, W Deutsch Herzzentrum Essen, Duisburg, Germany
[5] Med Spectrum Twente, Dept Epidemiol, Enschede, Netherlands
[6] Univ Twente, Dept Res Methodol Measurement & Data Anal, NL-7500 AE Enschede, Netherlands
[7] Cardiovasc Res Fdn, New York, NY USA
[8] Univ Twente, MIRA Inst Biomed Technol & Tech Med, NL-7500 AE Enschede, Netherlands
关键词
Coronary disease; intravascular ultrasound; ultrasonics; radio frequency; virtual histology; measurement reproducibility; LIPID-LOWERING THERAPY; VIRTUAL HISTOLOGY; INTRACORONARY ULTRASOUND; CLINICAL-APPLICATION; VULNERABLE PLAQUE; IN-VIVO; REGRESSION; VARIABILITY; PROGRESSION; ACCURACY;
D O I
10.4244/EIJV5I8A156
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To assess for the first time in a multicentre design the between-centre reproducibility of volumetric virtual histology intravascular ultrasound (VH-IVUS) measurements with a semi-automated, computer-assisted contour detection system in mild-to-moderately diseased coronary segments. Methods and results: Analysts of four European IVUS centres performed independent IVUS analyses (in total 7,188 cross-sectional analyses) and obtained volumetric data to evaluate the reproducibility of volumetric VH-IVUS measurements in 36 coronary segments (length 20.0 +/- 0.4 mm) from patients with stable angina. Geometric and compositional VH-IVUS measurements were highly correlated for the different comparisons. Overall intraclass correlation for vessel, lumen, plaque volume and plaque burden were 0.98, 0.92 0.95, and 0.86, respectively; for fibrous, fibro-lipidic, necrotic core and calcified volumes overall intraclass correlations were 0.95, 0.93, 0.99, and 1.00, respectively. There were significant but small differences for vessel, lumen, fibrous and calcified volumes, and there was no significant difference for plaque volume. Of the plaque components necrotic core and calcified volume showed on average the highest reproducibility. Conclusions: These findings underline the necessity to centrally analyse IVUS data obtained in multicentre studies addressing mild-to-moderately diseased coronary arteries. In addition, pooling VH-IVUS data from different studies, analysed at different centres, may be problematical.
引用
收藏
页码:925 / 931
页数:7
相关论文
共 13 条
  • [1] Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis
    Huisman, Jennifer
    Hartmann, Marc
    Mattern, Eline S. K.
    Mintz, Gary S.
    Basalus, Mounir W. Z.
    van Houwelingen, Gert K.
    Verhorst, Patrick M. J.
    von Birgelen, Clemens
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (05): : 487 - 497
  • [2] Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis
    Jennifer Huisman
    Marc Hartmann
    Eline S. K. Mattern
    Gary S. Mintz
    Mounir W. Z. Basalus
    Gert K. van Houwelingen
    Patrick M. J. Verhorst
    Clemens von Birgelen
    The International Journal of Cardiovascular Imaging, 2010, 26 : 487 - 497
  • [3] European multicenter study on the between-center reproducibility of volumetric radiofrequency-based intravascular ultrasound analyses in coronary lesions prior to stenting
    Huisman, J.
    Egede, R.
    Rdzanek, A.
    Boese, D.
    Erbel, R.
    Kochman, J.
    Jensen, L. O.
    Hartmann, M.
    Mintz, G. S.
    Von Birgelen, C.
    EUROPEAN HEART JOURNAL, 2011, 32 : 862 - 862
  • [4] Reproducibility of volumetric intravascular ultrasound radiofrequency-based analysis of coronary plaque composition in vivo
    Marc Hartmann
    Eline S. K. Mattern
    Jennifer Huisman
    Gert K. van Houwelingen
    Frits H. A. F. de Man
    Martin G. Stoel
    Peter W. Danse
    Hans W. Louwerenburg
    Clemens von Birgelen
    The International Journal of Cardiovascular Imaging, 2009, 25 : 13 - 23
  • [5] Reproducibility of volumetric intravascular ultrasound radiofrequency-based analysis of coronary plaque composition in vivo
    Hartmann, Marc
    Mattern, Eline S. K.
    Huisman, Jennifer
    van Houwelingen, Gert K.
    de Man, Frits H. A. F.
    Stoel, Martin G.
    Danse, Peter W.
    Louwerenburg, Hans W.
    von Birgelen, Clemens
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 (01): : 13 - 23
  • [6] Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented
    Jennifer Huisman
    Rasmus Egede
    Adam Rdzanek
    Dirk Böse
    Raimund Erbel
    Janusz Kochman
    Lisette Okkels Jensen
    Job van der Palen
    Marc Hartmann
    Gary S. Mintz
    Clemens von Birgelen
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1867 - 1878
  • [7] Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented
    Huisman, Jennifer
    Egede, Rasmus
    Rdzanek, Adam
    Boese, Dirk
    Erbel, Raimund
    Kochman, Janusz
    Jensen, Lisette Okkels
    van der Palen, Job
    Hartmann, Marc
    Mintz, Gary S.
    von Birgelen, Clemens
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08): : 1867 - 1878
  • [8] Reproducibility of Shin’s method for necrotic core and calcium content in atherosclerotic coronary lesions treated with bioresorbable everolimus-eluting vascular scaffolds using volumetric intravascular ultrasound radiofrequency-based analysis
    Eun-Seok Shin
    Hector M. Garcia-Garcia
    Giovanna Sarno
    Leif Thuesen
    Dariusz Dudek
    John A. Ormiston
    Patrick W. Serruys
    The International Journal of Cardiovascular Imaging, 2012, 28 : 43 - 49
  • [9] Reproducibility of Shin's method for necrotic core and calcium content in atherosclerotic coronary lesions treated with bioresorbable everolimus-eluting vascular scaffolds using volumetric intravascular ultrasound radiofrequency-based analysis
    Shin, Eun-Seok
    Garcia-Garcia, Hector M.
    Sarno, Giovanna
    Thuesen, Leif
    Dudek, Dariusz
    Ormiston, John A.
    Serruys, Patrick W.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (01): : 43 - 49
  • [10] Reproducibility of Shin's Method for Necrotic Core and Calcium Content in Atherosclerotic Coronary Lesions Treated With Bioresorbable Everolimus-Eluting Vascular Scaffolds Using Volumetric Intravascular Ultrasound Radiofrequency-Based Analysis
    Shin, Eun-Seok
    Garcia-Garcia, Hector M.
    Sarno, Giovanna
    Thuesen, Leif
    Dudek, Darius Z.
    Ormiston, John A.
    Serruys, Patrick W.
    CIRCULATION, 2010, 122 (21)