Determination of dibenzopyrenes in standard reference materials (SRM) 1649a, 1650, and 2975 using ultrasonically assisted extraction and LC–GC–MS

被引:0
|
作者
Christoffer Bergvall
Roger Westerholm
机构
[1] Stockholm University,Department of Analytical Chemistry, Arrhenius Laboratory
来源
关键词
PAH; Dibenzopyrenes; SRM 1649a; SRM 2975; SRM 1650; LC–GC–MS;
D O I
暂无
中图分类号
学科分类号
摘要
A method has been developed for analysis of the highly potent polycyclic aromatic hydrocarbon (PAH) carcinogens dibenzo(a,l)pyrene, dibenzo(a,h)pyrene, and dibenzo(a,i)pyrene (molecular weight 302) present in small amounts in diesel and air particulate material. The method can also be used for analysis of the PAH benzo(a)pyrene, coronene, and perylene, for which reference and certified values are available for the standard reference materials used for validation of the method—SRM 1649a (urban dust) and SRM 2975 (diesel particulate matter). The only NIST values that have been published for these dibenzopyrene isomers in the analyzed SRM are reference values for dibenzo(a,i)pyrene and dibenzo(a,h)pyrene in SRM 1649a. The concentrations determined in the SRM were in good agreement with reported NIST-certified and reference values and other concentrations reported in the literature. Standard reference material 1650 (diesel particulate matter) was also analyzed. The method could not, however, be validated using this material because certification of SRM 1650 had expired. The method is based on ultrasonically assisted extraction of the particulate material, then silica SPE pre-separation and isolation, and, separation and detection by hyphenated LC–GC–MS. The method is relatively rapid and requires only approximately 1–5 mg SRM particulate material to identify and quantify the analytes. Low extraction recoveries for the analytes, in particular the dibenzopyrenes, when extracting diesel SRM 2975 and 1650 resulted, however, in the dibenzopyrenes being present in amounts near their limits of quantifications in these samples. The method’s limit of quantification (LOQ), based on analyses of SRM 1649a, is in the range 10–77 pg. By use of this method more than 25 potential PAH isomers with a molecular weight of 302 could be separated.
引用
收藏
页码:438 / 447
页数:9
相关论文
共 50 条
  • [21] Determination of nucleating agents in plastic materials by GC/MS after microwave-assisted extraction with in situ microwave-assisted derivatization
    Sternbauer, Lucas
    Dieplinger, Johanna
    Buchberger, Wolfgang
    Marosits, Edit
    TALANTA, 2014, 128 : 63 - 68
  • [22] Metabolite Profiling of a NIST Standard Reference Material for Human Plasma (SRM 1950): GC-MS, LC-MS, NMR, and Clinical Laboratory Analyses, Libraries, and Web-Based Resources
    Simon-Manso, Yamil
    Lowenthal, Mark S.
    Kilpatrick, Lisa E.
    Sampson, Maureen L.
    Telu, Kelly H.
    Rudnick, Paul A.
    Mallard, W. Gary
    Bearden, Daniel W.
    Schock, Tracey B.
    Tchekhovskoi, Dmitrii V.
    Blonder, Niksa
    Yan, Xinjian
    Liang, Yuxue
    Zheng, Yufang
    Wallace, William E.
    Neta, Pedatsur
    Phinney, Karen W.
    Remaley, Alan T.
    Stein, Stephen E.
    ANALYTICAL CHEMISTRY, 2013, 85 (24) : 11725 - 11731
  • [23] Simultaneous determination of phthalate plasticizers in PVC packaging materials using homogeneous-ultrasonic extraction-GC-MS assisted with continuous wavelet transform
    Dong, Chun-hong
    Liu, Ying-fan
    Yang, Wei-fang
    Sun, Xiao-li
    Wang, Guo-qing
    ANALYTICAL METHODS, 2013, 5 (17) : 4513 - 4517
  • [24] CHARACTERIZATION OF ORGANIC EXTRACTS FROM STANDARD REFERENCE MATERIALS 1649, URBAN DUST ORGANICS, AND 1650, DIESEL PARTICULATE MATTER, USING A MICROSUSPENSION ASSAY - A WHO IPCS CSCM STUDY
    BAGLEY, ST
    STOLTZ, SL
    BECKER, DM
    KEEN, RE
    MUTATION RESEARCH, 1992, 276 (1-2): : 81 - 86
  • [25] Determination of cannabinoids in plasma using salting-out-assisted liquid-liquid extraction followed by LC-MS/MS analysis
    da Silva, Cristiane Pires
    Pugen Dalpiaz, Luiz Paulo
    Gerbase, Fernando Engel
    Muller, Victoria Vendramini
    da Silva, Anne Cezimbra
    Lizot, Lilian Feltraco
    Hahn, Roberta Zilles
    da Costa, Jose Luiz
    Antunes, Marina Venzon
    Linden, Rafael
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (12)
  • [26] Ultrasound-assisted extraction and on-line LC–GC–MS for determination of polycyclic aromatic hydrocarbons (PAH) in urban dust and diesel particulate matter
    Anders Christensen
    Conny Östman
    Roger Westerholm
    Analytical and Bioanalytical Chemistry, 2005, 381 : 1206 - 1216
  • [27] The determination of arsenic and selenium in standard reference materials using sector field ICP-MS in high resolution mode
    Townsend, AT
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (06): : 521 - 526
  • [28] The determination of arsenic and selenium in standard reference materials using sector field ICP-MS in high resolution mode
    Ashley T. Townsend
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 521 - 526
  • [29] DETERMINATION OF PESTICIDE RESIDUES IN TOMATOES TAKEN PERIODICALLY FROM CANAKKALE (TURKEY) PUBLIC MARKET USING QUECHERS EXTRACTION METHOD IN LC-MS/MS AND GC-MS/MS INSTRUMENTS
    Ciftci, Ugur
    Yildirim, Ismet
    FRESENIUS ENVIRONMENTAL BULLETIN, 2022, 31 (01): : 616 - 625
  • [30] Focused microwave-assisted Soxhlet extraction of acorn oil for determination of the fatty acid profile by GC–MS. Comparison with conventional and standard methods
    J. A. Pérez-Serradilla
    M. C. Ortiz
    L. Sarabia
    M. D. Luque de Castro
    Analytical and Bioanalytical Chemistry, 2007, 388 : 451 - 462