Determination of Mercury in Chinese-Prepared Medicine Using Closed Vessel Microwave Digestion with Cold-Vapor Atomic Absorption Spectrometry

被引:0
|
作者
Eng-Shi Ong
Yuk-Lin Yong
Soo-On Woo
Lek-Kim Kee
机构
[1] Institute of Science and Forensic Medicine,Department of Scientific Services
[2] Singapore Polytechnic,undefined
来源
Analytical Sciences | 2000年 / 16卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A method that is both simple and rapid for the determination of mercury in Chinese-prepared medicine (CPM) was developed. The method uses closed-vessel microwave digestion with final analysis by CVAAS with a sodium borohydride and hydroxylammonium hydrochloride solution. The accuracy of the method was checked using botanical-certified reference materials (BCR62, olive leaves), and close agreement with certified values was achieved. The precision of the method, based on different types of CPM samples and different analysts on different days at different levels of mercury, was found to be between 5.0 and 13.3% (relative standard deviation, n = 6). A comparison between two different types of vessels for closed-vessel microwave digestion was performed. Potential matrix interference, such as undecomposed organics and others in CPM samples, was investigated. The effect of a hydroxylammonium hydrochloride solution was also investigated, and was found to have a strong impact on the accuracy of the method. Finally, the method was used to prepare in-house reference materials. A simpler approach of using a statistical quality control (SQC) chart was used to assess the stability of the reference materials and to monitor the stability of the analytical procedures.
引用
收藏
页码:391 / 395
页数:4
相关论文
共 50 条
  • [41] Closed-ampule digestion procedure for the determination of mercury in soil and tissue using cold vapor atomic fluorescence spectrometry
    Jones, RD
    WestThomas, J
    Arfstrom, C
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1997, 59 (01) : 29 - 34
  • [42] Closed-ampule digestion procedure for the determination of mercury in soil and tissue using cold vapor atomic fluorescence spectrometry
    Jones R.D.
    West-Thomas J.
    Arfstrom C.
    Bulletin of Environmental Contamination and Toxicology, 1997, 59 (1) : 29 - 34
  • [43] Determination of mercury in dry fish samples by microwave digestion and flow injection analysis system cold vapor atomic absorption spectrometry
    dePaz, LA
    Alegria, A
    Barbera, R
    Farre, R
    Lagarda, MJ
    FOOD CHEMISTRY, 1997, 58 (1-2) : 169 - 172
  • [44] MICROWAVE DIGESTION FOR MERCURY DETERMINATION IN FISH-TISSUES AND BOTTOM SEDIMENTS BY AUTOMATED COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY
    FOSTIER, AH
    FERREIRA, JR
    DEANDRADE, MO
    QUIMICA NOVA, 1995, 18 (05): : 425 - 430
  • [45] EFFECT OF SELENIUM AND TELLURIUM IN THE ATOMIC-ABSORPTION DETERMINATION OF MERCURY BY THE COLD-VAPOR TECHNIQUE
    DIDORENKO, TO
    ZELYUKOVA, YV
    VOLKOVA, EA
    POLUEKTOV, NS
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1984, 39 (11): : 1619 - 1623
  • [46] Sequential injection analysis system for determination of mercury by cold-vapor atomic absorption spectroscopy
    de Mirabó, FMB
    Thomas, AC
    Rubí, E
    Forteza, R
    Cerdà, V
    ANALYTICA CHIMICA ACTA, 1997, 355 (2-3) : 203 - 210
  • [47] DETERMINATION OF MERCURY IN CROPS BY COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY AFTER MICROWAVE DISSOLUTION
    NAVARROALARCON, M
    LOPEZMARTINEZ, MC
    SANCHEZVINAS, M
    DELASERRANA, HL
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1991, 39 (12) : 2223 - 2225
  • [48] Determination of mercury in rice by cold vapor atomic fluorescence spectrometry after microwave-assisted digestion
    Jose da Silva, Maria
    Palm, Ana Paula S.
    Fernanda Pimentel, Maria
    Luisa Cervera, M.
    de la Guardia, Miguel
    ANALYTICA CHIMICA ACTA, 2010, 667 (1-2) : 43 - 48
  • [49] COLD-VAPOR MERCURY ATOMIC-ABSORPTION SPECTROMETRY .1. REAGENT VOLUME OPTIMIZATION
    DANIELS, RS
    WIGFIELD, DC
    SCIENCE OF THE TOTAL ENVIRONMENT, 1989, 89 (03) : 319 - 323
  • [50] COLD-VAPOR MERCURY ATOMIC-ABSORPTION SPECTROMETRY - HCL AS THE CAUSE OF THE DOUBLE PEAK PHENOMENON
    DANIELS, RS
    WIGFIELD, DC
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (04) : 196 - 198