An ROC Study of Chest Radiographs: 2K Versus 4K High-Resolution Soft-Copy Images

被引:0
|
作者
Su Young Kim
Yoon Joon Hwang
Yoon Hee Han
Jung Wook Seo
Ji Young Lee
Yong Hoon Kim
Soon Joo Cha
Gham Hur
Sung Soon Lee
机构
[1] Ilsan Paik Hospital,Department of Radiology
[2] Inje University School of Medicine,Department of Internal Medicine
[3] Ilsan Paik Hospital,undefined
[4] Inje University School of Medicine,undefined
来源
关键词
Observer performance; ROC; computed radiography; PACS;
D O I
暂无
中图分类号
学科分类号
摘要
Computed radiography of chest with a 4K image array was recently introduced. We performed a multiobserver study to compare the diagnostic accuracy of 2K (standard) and 4K (high quality) chest radiographs displayed on a 5-mega-pixel monitor (2K monitor). One hundred cases of posteroanterior chest radiographs (a total of 200 images) were selected by two chest radiologists. Those radiographs included pneumothorax (n = 14), nodules (n = 15), interstitial disease (n = 10), or neither abnormality (n = 61). These were interpreted by four radiologists in two separate sessions. They recorded their confidence scale for the presence or absence of abnormality. Diagnostic accuracy was determined by receiver operating characteristic (ROC) analysis for each observer. ROC analysis showed no statistically significant difference between the 2K and 4K modes for the detection of any of the different abnormalities by individual readers. Our preliminary study suggests that 2K mode would be sufficient for the detection of abnormality on chest radiograph and there is no considerable validity to incline toward the 4K mode in current picture archiving and communication system environment using 2K monitor. However, we think that additional investigation using more subtle parenchymal or rib lesion should be followed.
引用
收藏
相关论文
共 50 条
  • [21] HIGH-RESOLUTION ESCA STUDY OF URANIUM FLUORIDES - UF4 AND K2UF6
    PIREAUX, JJ
    MARTENSSON, N
    DIDRIKSSON, R
    SIEGBAHN, K
    RIGA, J
    VERBIST, J
    CHEMICAL PHYSICS LETTERS, 1977, 46 (02) : 215 - 219
  • [22] Micro- and macro-borderless surgery using a newly developed high-resolution (4K) three-dimensional video system
    Yagi, Shintaro
    Ito, Takashi
    Shirai, Hisaya
    Yao, Siyuan
    Masano, Yuki
    Ogawa, Eri
    Gabata, Ryosuke
    Uemoto, Shinji
    Kobayashi, Eiji
    PLOS ONE, 2021, 16 (05):
  • [23] Coordination of Ti4+ in silicate glasses: A high-resolution XANES spectroscopy study at the Ti K edge
    Farges, F
    AMERICAN MINERALOGIST, 1997, 82 (1-2) : 36 - 43
  • [24] HIGH-RESOLUTION SULFUR KBETA X-RAY-EMISSION SPECTRUM OF K2SO4
    MANNE, R
    KARRAS, M
    SUONINEN, E
    CHEMICAL PHYSICS LETTERS, 1972, 15 (01) : 34 - +
  • [25] A High-Throughput, contention-Free low-power, Radix-2 1k,2k, 4k and 8k-Point Fast Fourier Transform Engine using 28nm Standard-Cell Process
    Saleh, Hani H.
    Mohammad, Baker S.
    Maalouf, Maher
    2013 8TH INTERNATIONAL CONFERENCE ON DESIGN & TECHNOLOGY OF INTEGRATED SYSTEMS IN NANOSCALE ERA (DTIS), 2013, : 184 - 185
  • [26] High-resolution respirometry for the study of mitochondrial function in health and disease.: The OROBOROS Oxygraph-2k
    Garedew, A
    Hütter, E
    Haffner, B
    Gradl, P
    Gradl, L
    Jansen-Dürr, P
    Gnaiger, E
    Proceedings of the 11th Congress of the European Shock Society, 2005, : 107 - 111
  • [27] High-resolution respirometry for the study of mitochondrial function in health and disease. The OROBOROS Oxygraph-2k.
    Gnaiger, E
    SHOCK, 2005, 23 : 6 - 6
  • [28] Cs3H(SeO4)2 at 300 K by high-resolution neutron powder diffraction
    Sonntag, Rainer
    Melzer, Rolf
    Wessels, Thomas
    Radaelli, Pablo G.
    Acta Crystallographica, Section C: Crystal Structure Communications, 1997, 53 (pt 11): : 1529 - 1531
  • [29] Cs3H(SeO4)(2) at 300 K by high-resolution neutron powder diffraction
    Sonntag, R
    Melzer, R
    Wessels, T
    Radaelli, PG
    ACTA CRYSTALLOGRAPHICA SECTION C-CRYSTAL STRUCTURE COMMUNICATIONS, 1997, 53 : 1529 - 1531
  • [30] A high-resolution neutron study of Y2Fe15Cr2 at 77 K including magnetic properties
    Hao, YM
    Zhang, PL
    Zhang, JX
    Sun, XD
    Yan, QW
    Ridwan
    Mujamilah
    Gunawan
    Marsongkohadi
    JOURNAL OF PHYSICS-CONDENSED MATTER, 1996, 8 (09) : 1321 - 1324