An ROC Study of Chest Radiographs: 2K Versus 4K High-Resolution Soft-Copy Images

被引:0
|
作者
Su Young Kim
Yoon Joon Hwang
Yoon Hee Han
Jung Wook Seo
Ji Young Lee
Yong Hoon Kim
Soon Joo Cha
Gham Hur
Sung Soon Lee
机构
[1] Ilsan Paik Hospital,Department of Radiology
[2] Inje University School of Medicine,Department of Internal Medicine
[3] Ilsan Paik Hospital,undefined
[4] Inje University School of Medicine,undefined
来源
关键词
Observer performance; ROC; computed radiography; PACS;
D O I
暂无
中图分类号
学科分类号
摘要
Computed radiography of chest with a 4K image array was recently introduced. We performed a multiobserver study to compare the diagnostic accuracy of 2K (standard) and 4K (high quality) chest radiographs displayed on a 5-mega-pixel monitor (2K monitor). One hundred cases of posteroanterior chest radiographs (a total of 200 images) were selected by two chest radiologists. Those radiographs included pneumothorax (n = 14), nodules (n = 15), interstitial disease (n = 10), or neither abnormality (n = 61). These were interpreted by four radiologists in two separate sessions. They recorded their confidence scale for the presence or absence of abnormality. Diagnostic accuracy was determined by receiver operating characteristic (ROC) analysis for each observer. ROC analysis showed no statistically significant difference between the 2K and 4K modes for the detection of any of the different abnormalities by individual readers. Our preliminary study suggests that 2K mode would be sufficient for the detection of abnormality on chest radiograph and there is no considerable validity to incline toward the 4K mode in current picture archiving and communication system environment using 2K monitor. However, we think that additional investigation using more subtle parenchymal or rib lesion should be followed.
引用
收藏
相关论文
共 50 条
  • [1] An ROC study of chest radiographs: 2K versus 4K high-resolution soft-copy images
    Kim, Su Young
    Hwang, Yoon Joon
    Han, Yoon Hee
    Seo, Jung Wook
    Lee, Ji Young
    Kim, Yong Hoon
    Cha, Soon Joo
    Hur, Gham
    Lee, Sung Soon
    JOURNAL OF DIGITAL IMAGING, 2007, 20 (04) : 347 - 351
  • [2] Digital chest radiographs: An ROC study of the effect of 2K versus 4K matrix size on observer performance
    Miro, SP
    Leung, AN
    Rubin, GD
    Choi, Y
    Wexler, L
    Stark, P
    RADIOLOGY, 1998, 209P : 410 - 410
  • [3] RECEIVER-OPERATING-CHARACTERISTIC STUDY OF CHEST RADIOGRAPHS IN CHILDREN - DIGITAL HARD-COPY FILM VS 2K X 2K SOFT-COPY IMAGES
    RAZAVI, M
    SAYRE, JW
    TAIRA, RK
    SIMONS, M
    HUANG, HK
    CHUANG, KS
    RAHBAR, G
    KANGARLOO, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (02) : 443 - 448
  • [4] A comparison of high resolution storage phosphor radiographs (4K) and selenium radiographs (2K) in the detection of simulated chest lesions
    SchaeferProkop, CM
    Prokop, M
    Bolooreki, K
    Schmidt, A
    Kausche, H
    Siemund, R
    RADIOLOGY, 1997, 205 : 1252 - 1252
  • [5] Study comparing interpretation of hard copy and 1K- and 2K-resolution soft-copy images
    Aaron, JO
    Goldwin, RL
    Thebert, AR
    Peterson, GH
    Irwin, JP
    Hourigan, JS
    RADIOLOGY, 1996, 201 : 649 - 649
  • [6] Digital storage phosphor chest radiography:: An ROC study of the effect of 2K versus 4K matrix size on observer performance
    Miró, SPM
    Leung, AN
    Rubin, GD
    Choi, YH
    Kee, ST
    Mindelzun, RE
    Stark, P
    Wexler, L
    Plevritis, SK
    Betts, BJ
    RADIOLOGY, 2001, 218 (02) : 527 - 532
  • [7] Experimental comparision of noise and resolution for 2K and 4K storage phosphor chest radiography systems
    Flynn, MJ
    Samei, E
    Reimann, DA
    RADIOLOGY, 1996, 201 : 1082 - 1082
  • [8] Interpretation of chest radiographs in the intensive care unit: a hard- versus soft-copy comparative study
    Bricault, I
    Bosson, JL
    Declety, P
    Lavagne, P
    Ferretti, G
    JOURNAL DE RADIOLOGIE, 2003, 84 (09): : 993 - 999
  • [9] OBSERVER PERFORMANCE IN LOCALIZATION OF TUBE-CATHETER POSITION ON BEDSIDE CHEST RADIOGRAPHS - HARD-COPY VERSUS SOFT-COPY ENHANCED IMAGES
    NODINE, CF
    LIU, H
    MILLER, WT
    KUNDEL, HL
    RADIOLOGY, 1995, 197 : 527 - 527
  • [10] Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems
    Department of Diagnostic Radiology, Henry Ford Health System, Detroit, MI 48202, United States
    不详
    不详
    Med. Phys., 8 (1612-1622):