Seismic Performance Assessment of a Conventional Multi-storey Building

被引:0
|
作者
Giuseppe Marcantonio Del Gobbo
Martin S. Williams
Anthony Blakeborough
机构
[1] University of Oxford,Department of Engineering Science
关键词
Eurocode 8; FEMA P-58; Nonstructural systems; Seismic performance assessment;
D O I
暂无
中图分类号
学科分类号
摘要
Recent earthquakes have revealed that conventional seismic design philosophy allows for large levels of nonstructural damage. Nonstructural earthquake damage results in extensive repair costs and lengthy functional disruptions, as nonstructural systems comprise the majority of building investment and are essential to building operations. A better understanding of the expected overall seismic performance of code-compliant buildings is needed. This study investigates the seismic performance of a conventional building. A 16-storey steel office building was designed using a modern seismic structural code (Eurocode 8). This study is the first to assess in detail the substantial earthquake repair costs expected in a modern Eurocode concentric braced frame structure, considering nonstructural systems with the FEMA P-58 procedure. The breakdown of total repair costs by engineering demand parameter and by fragility group is novel. The seismic performance assessment indicated that substantial earthquake repair costs are expected. Limitations of the Eurocode nonstructural damage methodology were revealed in a novel manner using FEMA P-58, as the prescribed drift limits did not minimize nonstructural repair costs. These findings demonstrate the need for design procedures that improve nonstructural seismic performance. The study results provide a benchmark on which to evaluate retrofit alternatives for existing buildings and design options for new structures.
引用
下载
收藏
页码:237 / 245
页数:8
相关论文
共 50 条
  • [21] Assessment of A Rainwater Harvesting System in A Multi-Storey Residential Building in Brazil
    Maykot, Jessica Kuntz
    Ghisi, Enedir
    WATER, 2020, 12 (02)
  • [22] Thermal performance of bedrooms in a multi-storey residential building in southern Brazil
    Ghisi, Enedir
    Massignani, Ricardo Felipe
    BUILDING AND ENVIRONMENT, 2007, 42 (02) : 730 - 742
  • [23] The Impact of Antenna Selection and Location on the Performance of DAS in a Multi-storey Building
    Alade, Temitope
    Zhu, Huiling
    Osman, Hassan
    2013 IEEE WIRELESS COMMUNICATIONS AND NETWORKING CONFERENCE (WCNC), 2013, : 3213 - 3218
  • [24] Multi-storey building estate project in Astana
    不详
    BAUINGENIEUR, 2009, 84 : A19 - A19
  • [25] Multi-Storey Conservatories in Residential Building.
    Brillinger, Martin H.
    Kunststoffe im Bau, 1985, 20 (04): : 172 - 173
  • [26] RESURGENCE OF STEEL MULTI-STOREY BUILDING.
    Lott, Brian
    Civil engineering London, 1984, : 19 - 20
  • [27] DYNAMIC CHARACTERISTICS OF A MULTI-STOREY CONCRETE BUILDING
    WARD, HS
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS, 1969, 43 (AUG): : 553 - &
  • [28] Rational use of HPSFRC in multi-storey building
    Buka-Vaivade, K.
    Sliseris, J.
    Serdjuks, D.
    Pakrastins, L.
    Vatin, N., I
    MAGAZINE OF CIVIL ENGINEERING, 2018, 84 (08): : 3 - 14
  • [29] MULTI-STOREY OFFICE BUILDING FOR MPS AT BONN
    PLAPPERT, KH
    TECHNISCHE MITTEILUNGEN KRUPP WERKSBERICHTE, 1969, 27 (04): : 145 - &
  • [30] Evaluation of residual drift demands in regular multi-storey frames for performance-based seismic assessment
    Ruiz-Garcia, Jorge
    Miranda, Eduardo
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2006, 35 (13): : 1609 - 1629