Solid Reference Electrode of Metallurgical Oxygen Sensor

被引:0
|
作者
Tian-jun Lou
Xiang-hua Kong
Ke-qin Huang
Qing-guo Liu
机构
[1] Henan Institute of Science and Technology,Department of Chemistry and Engineering
[2] University of Science and Technology Beijing,Department of Materials Physics and Chemistry
[3] University of Science and Technology Beijing,Laboratory for Solid State Ionics
关键词
ZrO; solid electrolyte; oxygen sensor; reference electrode;
D O I
暂无
中图分类号
学科分类号
摘要
The thermal equilibrium state of the reference electrode was investigated. The results show that the temperature difference between the inside and the outside of zirconia tube was very small and the Seebeck effect can be ignored after the sensor was dipped into liquid steel for more than 2 s. A special sensor was designed to test the relation between the EMF (electromotive force) of sensor and the thermal equilibrium state of the reference electrode. Based on these results, it is suggested that the peak in EMF curve was caused by the change of oxygen potential in reference electrode before the thermal equilibrium was reached. If NiO was added by 2 %–5 % to the Cr/Cr2 O3 reference electrode, the peak in EMF curve could be eliminated.
引用
收藏
页码:18 / 20
页数:2
相关论文
共 50 条
  • [1] Solid Reference Electrode of Metallurgical Oxygen Sensor
    LOU Tian-jun~1
    2. Department of Materials Physics and Chemistry
    3. Laboratory for Solid State Ionics
    [J]. Journal of Iron and Steel Research(International), 2006, (05) : 18 - 20
  • [2] Solid reference electrode of metallurgical oxygen sensor
    Lou Tian-jun
    Kong Xiang-hua
    Huang Ke-qin
    Liu Qing-guo
    [J]. JOURNAL OF IRON AND STEEL RESEARCH INTERNATIONAL, 2006, 13 (05) : 18 - +
  • [3] POTENTIOMETRIC OXYGEN SENSOR WITH SOLID STATE REFERENCE ELECTRODE
    Dunst, Katarzyna
    Jasinski, Grzegorz
    Jasinski, Piotr
    [J]. METROLOGY AND MEASUREMENT SYSTEMS, 2014, 21 (02) : 205 - 216
  • [4] Performance of solid electrolyte oxygen sensor with solid and liquid reference electrode for liquid metal
    Adhi, Pribadi Mumpuni
    Kondo, Masatoshi
    Takahashi, Minoru
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 : 1261 - 1269
  • [5] Distribution of oxygen potential in ZrO2-based solid electrolyte and selection of reference electrode of oxygen sensor
    Li, FS
    Tang, YH
    Li, LF
    [J]. SOLID STATE IONICS, 1996, 86-8 : 1027 - 1031
  • [6] Fe-based Solid Reference Electrode Utilized in YSZ-Based Oxygen Sensor
    Jin, Han
    Breedon, Michael
    Tanaka, Yuki
    Miura, Norio
    [J]. ECS ELECTROCHEMISTRY LETTERS, 2013, 2 (01) : B1 - B3
  • [7] Solid state pH and chloride sensor with microfluidic reference electrode
    Zevenbergen, M. A. G.
    Altena, G.
    Dam, V. A. T.
    Goedbloed, M.
    Bembnowicz, P.
    McGuinness, P.
    Berney, H.
    Berduque, A.
    O'Dwyer, T.
    van Schaijk, R.
    [J]. 2016 IEEE INTERNATIONAL ELECTRON DEVICES MEETING (IEDM), 2016,
  • [8] Complete Solid State Dissolved Oxygen Sensor Using Hemin Electrocatalyst and Palladium-Reusable Reference Electrode
    Hsu, Leo
    Deen, M. Jamal
    Selvaganapathy, P. Ravi
    [J]. IEEE SENSORS JOURNAL, 2018, 18 (03) : 941 - 947
  • [9] INTERNAL-REFERENCE SOLID-ELECTROLYTE OXYGEN SENSOR
    HAALAND, DM
    [J]. ANALYTICAL CHEMISTRY, 1977, 49 (12) : 1813 - 1817
  • [10] Research on Oxygen Sensor for Metallurgical Process
    KONG Xiang-hua
    WANG Xiao-feng
    LIU Qing-guo
    [J]. Journal of Iron and Steel Research(International), 2001, 8 (01) : 60 - 62