Complete Solid State Dissolved Oxygen Sensor Using Hemin Electrocatalyst and Palladium-Reusable Reference Electrode

被引:1
|
作者
Hsu, Leo [1 ,2 ]
Deen, M. Jamal [3 ]
Selvaganapathy, P. Ravi [4 ]
机构
[1] McMaster Univ, Sch Biomed Engn, Hamilton, ON L8S 4L8, Canada
[2] Tufts Univ, Dept Biomed Engn, Medford, MA 02155 USA
[3] McMaster Univ, Sch Biomed Engn, Dept Elect Engn, Hamilton, ON L8S 4L8, Canada
[4] McMaster Univ, Sch Biomed Engn, Dept Mech Engn, Hamilton, ON L8S 4L8, Canada
关键词
Dissolved oxygen; electrochemical sensor; palladium reference electrode; Hemin electrocatalyst; solid state; GLASSY-CARBON ELECTRODE; REDUCED GRAPHENE OXIDE; LIQUID-JUNCTION; TETRASULFONATED PHTHALOCYANINE; AMPEROMETRIC SENSOR; FILM; REMOVAL; POLYMER;
D O I
10.1109/JSEN.2017.2778378
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dissolved oxygen (DO) is essential for aquatic life, but is consumed during the decomposition process of the organic matter in water. It is used as a primary indicator of water quality, and is also crucial for the efficiency of the waste water treatment process. Hence, a sensitive, long term reliable, in-line DO sensor is essential for sustainability of water ecosystems and management of water resources. This paper introduces a low-cost, all-solid state DO sensing device by the integration of polyhemin-based DO sensitive electrode and Pd/H reference electrode. Low cost electrodeposition techniques are applied in both the DO sensitive electrode and the Pd/H reference electrode synthesis. First, the operation parameters of the Pd/H reference electrode was characterized to obtain the adequate lifetime and response time of reference for DO sensing application. The regeneration procedure of the reference electrode is also investigated to achieve multi-usage of this Pd/H electrode. Consequently, this DO sensing device has a sensitivity of 1.3 (mu A/cm(2))/(mg/L) over a DO concentration range of 1.5-20 mg/L. The DO sensing applications in various water samples including tap water, simulated surface water and wastewater are also demonstrated. The all solid-state feature allows this sensing device to be applied as a long-term DO sensor for continuous, in-situ water monitoring.
引用
收藏
页码:941 / 947
页数:7
相关论文
共 50 条
  • [1] POTENTIOMETRIC OXYGEN SENSOR WITH SOLID STATE REFERENCE ELECTRODE
    Dunst, Katarzyna
    Jasinski, Grzegorz
    Jasinski, Piotr
    [J]. METROLOGY AND MEASUREMENT SYSTEMS, 2014, 21 (02) : 205 - 216
  • [2] Solid Reference Electrode of Metallurgical Oxygen Sensor
    LOU Tian-jun~1
    2. Department of Materials Physics and Chemistry
    3. Laboratory for Solid State Ionics
    [J]. Journal of Iron and Steel Research(International), 2006, (05) : 18 - 20
  • [3] Solid reference electrode of metallurgical oxygen sensor
    Lou Tian-jun
    Kong Xiang-hua
    Huang Ke-qin
    Liu Qing-guo
    [J]. JOURNAL OF IRON AND STEEL RESEARCH INTERNATIONAL, 2006, 13 (05) : 18 - +
  • [4] Solid Reference Electrode of Metallurgical Oxygen Sensor
    Tian-jun Lou
    Xiang-hua Kong
    Ke-qin Huang
    Qing-guo Liu
    [J]. Journal of Iron and Steel Research International, 2006, 13 : 18 - 20
  • [5] A SOLID-STATE DISSOLVED-OXYGEN SENSOR BASED ON THE MICROHOLE ARRAY ELECTRODE
    MORITA, K
    SHIMIZU, Y
    [J]. DENKI KAGAKU, 1990, 58 (12): : 1190 - 1196
  • [6] Microfabricated solid-state dissolved oxygen sensor
    McLaughlin, GW
    Braden, K
    Franc, B
    Kovacs, GTA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 83 (1-3) : 138 - 148
  • [7] Solid state pH and chloride sensor with microfluidic reference electrode
    Zevenbergen, M. A. G.
    Altena, G.
    Dam, V. A. T.
    Goedbloed, M.
    Bembnowicz, P.
    McGuinness, P.
    Berney, H.
    Berduque, A.
    O'Dwyer, T.
    van Schaijk, R.
    [J]. 2016 IEEE INTERNATIONAL ELECTRON DEVICES MEETING (IEDM), 2016,
  • [8] Performance of solid electrolyte oxygen sensor with solid and liquid reference electrode for liquid metal
    Adhi, Pribadi Mumpuni
    Kondo, Masatoshi
    Takahashi, Minoru
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 : 1261 - 1269
  • [9] THE DEVELOPMENT OF A SOLID-STATE, 5-MS DISSOLVED-OXYGEN SENSOR
    HUDSON, RD
    EATON, GM
    [J]. OCEANS 89, VOL 1-6: AN INTERNATIONAL CONFERENCE ADDRESSING METHODS FOR UNDERSTANDING THE GLOBAL OCEAN, 1989, : 1588 - 1593
  • [10] A Highly Miniaturized Dissolved Oxygen Sensor Using a Nanoporous Platinum Electrode Electroplated on Silicon
    Lee, Yi Jae
    Park, Jae Yeong
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 58 (05) : 1505 - 1510