A meta-analytic comparison of echocardiographic stressors

被引:7
|
作者
Yoshinori Noguchi
Shizuko Nagata-Kobayashi
James E Stahl
John B Wong
机构
[1] Fujita Health University School of Medicine,Division of General Internal Medicine, Department of Medicine
[2] Kyoto University Graduate School of Medicine,Department of General Medicine and Clinical Epidemiology
[3] Massachusetts General Hospital,MGH
[4] Tufts University School of Medicine,Institute for Technology Assessment
关键词
meta-analysis; SROC analysis; stress echocardiography; test characteristics;
D O I
暂无
中图分类号
学科分类号
摘要
Background: The relative performance of alternative stressors for stress echocardiography for the diagnosis of coronary artery disease (CAD) is not well established. Methods: All studies published between 1981 to December 2001 who met inclusion criteria were included in this analysis. We performed a summary receiver operator characteristic (SROC) analysis and calculated weighted mean of the likelihood ratio and sensitivity/specificity. A covariate analysis using meta-regression methods was also performed. Results: Forty-four studies presented data on Exercise, 11 on Adenosine, 80 on Dobutamine, 40 on Dipyridamole, 16 on transatrial pacing transesophageal echocardiography (Tap-TEE), and 7 on transatrial pacing transthorasic echocardiography (Tap-TTE). SROC analysis showed that the following order of most discriminatory to least: Tap-TEE, Exercise, Dipyridamole, Dobutamine and Adenosine. Weighted means sensitivity/specificity were Exercise: 82.6/84.4%, Adenosine: 68.4/80.9%, Dobutamine: 79.6/85.1%, Dipyridamole: 71.0/92.2%, Tap-TTE: 90.7/86.1%, and Tap-TEE: 86.2/91.3%. Covariate analysis showed that the discriminatory power of Exercise decreased with increasing mean age. Conclusions: Tap-TEE is a very accurate test for both ruling in and ruling out CAD although its invasiveness may limit its clinical acceptability. Exercise is a well-balanced satisfactory test for both ruling in and ruling out but performance might be lower for the elderly. Dobutamine offers a reasonable compromise for Exercise. Dipyridamole might be good for ruling in but not for ruling out CAD. The incapability in ruling-out CAD was a major problem in clinical application of the stress. Adenosine was the least useful stressor in diagnosing CAD.
引用
收藏
页码:189 / 207
页数:18
相关论文
共 50 条
  • [21] META-ANALYTIC STUDIES IN PSYCHOLOGY
    Kornilov, S. A.
    Kornilova, T. V.
    [J]. PSIKHOLOGICHESKII ZHURNAL, 2010, 31 (06) : 5 - 17
  • [22] A NEW META-ANALYTIC APPROACH
    RAJU, NS
    BURKE, MJ
    NORMAND, J
    LANGLOIS, GM
    [J]. JOURNAL OF APPLIED PSYCHOLOGY, 1991, 76 (03) : 432 - 446
  • [23] Pride: A Meta-Analytic Project
    Dickens, Leah R.
    Robins, Richard W.
    [J]. EMOTION, 2022, 22 (05) : 1071 - 1087
  • [24] The reliability of meta-analytic review
    Zakzanis, KK
    [J]. PSYCHOLOGICAL REPORTS, 1998, 83 (01) : 215 - 222
  • [25] Bayesian Meta-Analytic Measure
    Martins, Camila B.
    Pereira, Carlos A. de B.
    Polpo, Adriano
    [J]. BAYESIAN INFERENCE AND MAXIMUM ENTROPY METHODS IN SCIENCE AND ENGINEERING, MAXENT 37, 2018, 239 : 37 - 42
  • [26] Meta-analytic methods for criminology
    Wilson, DB
    [J]. ANNALS OF THE AMERICAN ACADEMY OF POLITICAL AND SOCIAL SCIENCE, 2001, 578 : 71 - 89
  • [27] AFTER THE META-ANALYTIC REVOLUTION
    BAUSELL, RB
    [J]. EVALUATION & THE HEALTH PROFESSIONS, 1993, 16 (01) : 3 - 12
  • [28] A meta-analytic investigation of cyberloafing
    Mercado, Brittany K.
    Giordano, Casey
    Dilchert, Stephan
    [J]. CAREER DEVELOPMENT INTERNATIONAL, 2017, 22 (05) : 546 - 564
  • [29] A Meta-Analytic Examination of Hardiness
    Eschleman, Kevin J.
    Bowling, Nathan A.
    Alarcon, Gene M.
    [J]. INTERNATIONAL JOURNAL OF STRESS MANAGEMENT, 2010, 17 (04) : 277 - 307
  • [30] A REVIEW OF META-ANALYTIC TECHNIQUES
    BRINBERG, D
    JACCARD, J
    [J]. ADVANCES IN CONSUMER RESEARCH, 1986, 13 : 606 - 611