A novel approach to quality assurance of radiation treatments with a visual interface of GEANT4 for Varian TrueBeam STx

被引:0
|
作者
Oguzhan Ayrancioglu
Kadir Akgungor
机构
[1] Dokuz Eylul University,Department of Medical Physics
[2] Dokuz Eylul University,Department of Atomic and Molecular Physics
来源
Journal of the Korean Physical Society | 2024年 / 84卷
关键词
Radiotherapy; geant4; Visual interface; Varian truebeam stx; Quality assurance;
D O I
暂无
中图分类号
学科分类号
摘要
The Monte Carlo (MC) technique, widely recognized as one of the most reliable methods for simulating radiation transport, is commonly employed in radiotherapy. An MC-based simulation softwares such as GEANT4, require a certain level of programing knowledge due to its complex structure. Through the visual interface we have developed, the Varian TrueBeam STx machine used in radiotherapy treatments can be easily utilized in GEANT4 calculations for the treatment quality assurance (QA). Following the geometric modeling and validation of the Varian TrueBeam STx for GEANT4, a graphical user interface (GUI) was designed that allows the use of various parameters of the simulation model by providing user-defined inputs. During the interface design, the QT framework was employed for the GUI, while the coding section involved the use of Python and C +  + programing languages. The visual interface enables the dynamic transfer of optional simulation information, generated either through user input or obtained from the Varian Eclipse treatment planning system (TPS) to the simulation model. This allows the execution of the GEANT4 simulation. The usage of simulation parameters available in the GUI and the transfer of these parameters to the GEANT4 were tested on CentOS (7), Ubuntu (20.04.6 LTS), Mint (20.3 Una), and MacOS (14.2.1 Sonoma) operating systems. The visual interface of the Varian TrueBeam STx has been introduced as a user-friendly visual interface for medical physicists aiming to perform MC studies using the Varian TrueBeam STx. It is designed for ease of use and shows promise as a third-party quality assurance add-on for clinical applications of radiation therapy.
引用
收藏
页码:799 / 811
页数:12
相关论文
共 15 条
  • [1] A novel approach to quality assurance of radiation treatments with a visual interface of GEANT4 for Varian TrueBeam STx
    Ayrancioglu, Oguzhan
    Akgungor, Kadir
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 84 (10) : 799 - 811
  • [2] A Comprehensive Geant4 Monte Carlo Model of Multileaf Collimator for Varian TrueBeam Linac
    Kandlakunta, P.
    Zhang, T.
    Mutic, S.
    Khan, R.
    MEDICAL PHYSICS, 2017, 44 (06) : 2909 - 2909
  • [3] Monte Carlo Simulations for Quality Assurance of Varian TrueBeam 10XFFF VMAT SABR Treatments
    Gete, E.
    Bergman, A.
    Duzenli, C.
    Lee, R.
    Viel, F.
    Teke, T.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Monte Carlo Simulations for Quality Assurance of Varian TrueBeam 6MV FFF RapidArc SBRT Treatments
    Teke, T.
    Duzenli, C.
    Mestrovic, A.
    Hyde, D.
    Milette, M.
    Popescu, I.
    Gete, E.
    MEDICAL PHYSICS, 2012, 39 (06) : 3997 - 3997
  • [5] Monte Carlo simulation using PRIMO code as a tool for checking the credibility of commissioning and quality assurance of 6 MV TrueBeam STx varian LINAC
    Efendi, M. Arif
    Funsian, Amporn
    Chittrakarn, Thawat
    Bhongsuwan, Tripob
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (01) : 125 - 132
  • [6] Research in Geant4 electromagnetic physics design, and its effects on computational performance and quality assurance
    Augelli, M.
    Begalli, M.
    Hauf, S.
    Kim, C. H.
    Kuster, M.
    Pia, M. G.
    Queiroz Filho, P.
    Quintieri, L.
    Saracco, P.
    Santos, D. Souza
    Weidenspointner, G.
    Zoglauer, A.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 177 - +
  • [7] Radiation attenuation properties of novel glass system using experimental and Geant4 simulation
    Aladailah, M. W.
    Tashlykov, O. L.
    Shirmanov, I. A.
    Strugov, E. D.
    Sayyed, M. I.
    Marashdeh, Mohammad W.
    Elsafi, M.
    Al-Maaitah, A. F.
    RADIATION PHYSICS AND CHEMISTRY, 2022, 199
  • [8] A GATE/Geant4 beam model for the MedAustron non-isocentric proton treatment plans quality assurance
    Elia, Alessio
    Resch, Andreas Franz
    Carlino, Antonio
    Boehlen, Till Tobias
    Fuchs, Hermann
    Palmans, Hugo
    Letellier, Virgile
    Dreindl, Ralf
    Osorio, Jhonnatan
    Stock, Markus
    Sarrut, David
    Grevillot, Loic
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 71 : 115 - 123
  • [9] In-beam quality assurance using induced β+ activity in hadrontherapy: a preliminary physical requirements study using Geant4
    Lestand, L.
    Montarou, G.
    Force, P.
    Pauna, N.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (20): : 6497 - 6518
  • [10] Evaluation of GATE-RTion (GATE/Geant4) Monte Carlo simulation settings for proton pencil beam scanning quality assurance
    Winterhalter, Carla
    Taylor, Michael
    Boersma, David
    Elia, Alessio
    Guatelli, Susanna
    Mackay, Ranald
    Kirkby, Karen
    Maigne, Lydia
    Ivanchenko, Vladimir
    Resch, Andreas F.
    Sarrut, David
    Sitch, Peter
    Vidal, Marie
    Grevillot, Loic
    Aitkenhead, Adam
    MEDICAL PHYSICS, 2020, 47 (11) : 5817 - 5828