Hyperpolarized 3He lung ventilation imaging with B1-inhomogeneity correction in a single breath-hold scan

被引:0
|
作者
G. W. Miller
T. A. Altes
J. R. Brookeman
E. E. de Lange
J. P. Mugler III
机构
[1] Department of Radiology (Research),Center for In
关键词
Hyperpolarized gas MRI; Lung ventilation imaging; B1 inhomogeneity;
D O I
暂无
中图分类号
学科分类号
摘要
The signal-to-noise ratio (SNR) of hyperpolarized noble gas MR images is sensitive to the flip angle used. Variations in flip angle due to B1-inhomogeneity of the RF coil cause intensity variation artifacts in lung ventilation images which may mask or mimic disease. We show these artifacts can be minimized by using the optimal flip angle and corrected if the local flip angle is known. Hyperpolarized 3He lung images were obtained in ten healthy subjects using both a conventional gradient-echo sequence and a new hybrid pulse sequence designed to simultaneously acquire lung ventilation images and corresponding flip-angle maps in comparable imaging time. Flip-angle maps and corrected images were calculated from the hybrid scan and compared with conventional images. The qualitative theoretical dependence of flip angle on SNR was verified. Ventilation images and flip-angle maps were successfully obtained with the hybrid sequence. Corrections to image intensity calculated from the flip-angle maps appeared reasonable for images acquired using an average flip angle near optimal. Use of the optimal flip angle is crucial to the quality of lung ventilation images. Artifactual intensity variations due to RF-coil inhomogeneity may be identified and potentially corrected using our hybrid sequence.
引用
收藏
页码:218 / 226
页数:8
相关论文
共 50 条
  • [21] Lung air spaces:: MR imaging evaluation with hyperpolarized 3He gas
    de Lange, EE
    Mugler, JP
    Brookeman, JR
    Knight-Scott, J
    Truwit, JD
    Teates, CD
    Daniel, TM
    Bogorad, PL
    Cates, GD
    RADIOLOGY, 1999, 210 (03) : 851 - 857
  • [22] Dynamic echo planar MR imaging of lung ventilation with hyperpolarized 3He in normal subjects and patients with severe emphysema
    Gierada, DS
    Saam, B
    Yablonskiy, D
    Cooper, JD
    Lefrak, SS
    Conradi, MS
    NMR IN BIOMEDICINE, 2000, 13 (04) : 176 - 181
  • [23] Comparison of hyperpolarized 3He MRI with Xe-enhanced computed tomography imaging for ventilation mapping of rat lung
    Santyr, Giles E.
    Couch, Marcus J.
    Lam, Wilfred W.
    Ouriadov, Alexei
    Drangova, Maria
    McCormack, David G.
    Holdsworth, David W.
    NMR IN BIOMEDICINE, 2011, 24 (09) : 1073 - 1080
  • [24] Indacaterol/glycopyrronium increases lung ventilation in COPD patients as measured by hyperpolarized 3He MRI
    Tillmann, Hanns-Christian
    Singh, David
    Saralaya, Dinesh
    Lawson, Rod
    Wild, Jim
    Goldin, Jonathan
    Kostikas, Konstantinos
    Smith, Kristin
    Machineni, Surendra
    Yates, Denise
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [25] Fast Determination of Flip Angle and T1 in Hyperpolarized Gas MRI During a Single Breath-Hold
    Jianping Zhong
    Weiwei Ruan
    Yeqing Han
    Xianping Sun
    Chaohui Ye
    Xin Zhou
    Scientific Reports, 6
  • [26] Differences in hyperpolarized 3He ventilation imaging after 4 years in adults with cystic fibrosis
    Paulin, Gregory A.
    Svenningsen, Sarah
    Jobse, Brian N.
    Mohan, Sindu
    Kirby, Miranda
    Lewis, James F.
    Parraga, Grace
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (06) : 1701 - 1707
  • [27] Hyperpolarized 3He magnetic resonance imaging of ventilation after bacterial lipopolysaccharide exposure in mice
    Thomas, Abraham
    Voltz, James
    Fubara, Boma
    Driehuys, Bastiaan
    Zeldin, Darryl
    FASEB JOURNAL, 2008, 22
  • [28] Fast Determination of Flip Angle and T1 in Hyperpolarized Gas MRI During a Single Breath-Hold
    Zhong, Jianping
    Ruan, Weiwei
    Han, Yeqing
    Sun, Xianping
    Ye, Chaohui
    Zhou, Xin
    SCIENTIFIC REPORTS, 2016, 6
  • [29] Dynamic 3He imaging for quantification of regional lung ventilation parameters
    Dupuich, D
    Berthezène, Y
    Clouet, PL
    Stupar, V
    Canet, E
    Crémillieux, Y
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) : 777 - 783
  • [30] Diffusion lung imaging of hyperpolarized 3He in patients with emphysema: Changes in the structure of alveoli
    Yablonskiy, DA
    Saam, BT
    Gierada, DS
    Lefrak, SS
    Cooper, JD
    Conradi, MS
    RADIOLOGY, 1999, 213P : 344 - 344