Validation of 4D flow CMR against simultaneous invasive hemodynamic measurements: a swine study

被引:0
|
作者
Kelly Stam
Raluca G. Chelu
Nikki van der Velde
Richard van Duin
Piotr Wielopolski
Koen Nieman
Daphne Merkus
Alexander Hirsch
机构
[1] University Medical Center Rotterdam,Department of Cardiology, Thoraxcenter, Erasmus MC
[2] University Medical Center Rotterdam,Department of Radiology and Nuclear Medicine, Erasmus MC
关键词
4D flow CMR; Flow measurement; Invasive flow probe; Swine;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to compare invasively measured aorta flow with 2D phase contrast flow and 4D flow measurements by cardiovascular magnetic resonance (CMR) imaging in a large animal model. Nine swine (mean weight 63 ± 4 kg) were included in the study. 4D flow CMR exams were performed on a 1.5T MRI scanner. Flow measurements were performed on 4D flow images at the aortic valve level, in the ascending aorta, and main pulmonary artery. Simultaneously, flow was measured using an invasive flow probe, placed around the ascending aorta. Additionally, standard 2D phase contrast flow and 2D left ventricular (LV) volumetric data were used for comparison. The correlations of cardiac output (CO) between the invasive flow probe, and CMR modalities were strong to very strong. CO measured by 4D flow CMR correlated better with the CO measured by the invasive flow probe than 2D flow CMR flow and volumetric LV data (4D flow CMR: Spearman’s rho = 0.86 at the aortic valve level and 0.90 at the ascending aorta level; 2D flow CMR: 0.67 at aortic valve level; LV measurements: 0.77). In addition, there tended to be a correlation between mean pulmonary artery flow and aorta flow with 4D flow (Spearman’s rho = 0.65, P = 0.07), which was absent in measurements obtained with 2D flow CMR (Spearman’s rho = 0.40, P = 0.33). This study shows that aorta flow can be accurately measured by 4D flow CMR compared to simultaneously measured invasive flow. This helps to further validate the quantitative reliability of this technique.
引用
收藏
页码:1111 / 1118
页数:7
相关论文
共 50 条
  • [1] Validation of 4D flow CMR against simultaneous invasive hemodynamic measurements: a swine study
    Stam, Kelly
    Chelu, Raluca G.
    van der Velde, Nikki
    van Duin, Richard
    Wielopolski, Piotr
    Nieman, Koen
    Merkus, Daphne
    Hirsch, Alexander
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (06): : 1111 - 1118
  • [2] Intraindividual validation of 4D flow measurement against 2D flow measurements in aortas with bicuspid or tricuspid valves by cardiovascular magnetic resonance (CMR)
    Ahmed E Kharabish
    Kristina Belker
    Christian Meierhofer
    Stefan Martinoff
    Peter Ewert
    Heiko Stern
    Sohrab Fratz
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [3] Validation of blood flow partitioning in 4D phase contrast CMR measurements using lagrangian coherent structures
    Töger J.
    Carlsson M.
    Söderlind G.
    Arheden H.
    Heiberg E.
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [4] Remote CMR 4D Flow Quantification of Pulmonary Flow
    Raluca G Saru
    Kevin Wanambiro
    Albert Hsiao
    Laurens E Swart
    Sara Boccalini
    Mika Vogel
    Ricardo Budde
    Shreyas Vasanawala
    Jolien Roos-Hesselink
    Koen Nieman
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [5] Kat-ARC accelerated 4D flow CMR: clinical validation for transvalvular flow and peak velocity assessment
    Assadi, Hosamadin
    Uthayachandran, Bhalraam
    Li, Rui
    Wardley, James
    Nyi, Tha H.
    Grafton-Clarke, Ciaran
    Swift, Andrew J.
    Solana, Ana Beatriz
    Aben, Jean-Paul
    Thampi, Kurian
    Hewson, David
    Sawh, Chris
    Greenwood, Richard
    Hughes, Marina
    Kasmai, Bahman
    Zhong, Liang
    Flather, Marcus
    Vassiliou, Vassilios S.
    Garg, Pankaj
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2022, 6 (01)
  • [6] Kat-ARC accelerated 4D flow CMR: clinical validation for transvalvular flow and peak velocity assessment
    Hosamadin Assadi
    Bhalraam Uthayachandran
    Rui Li
    James Wardley
    Tha H. Nyi
    Ciaran Grafton-Clarke
    Andrew J. Swift
    Ana Beatriz Solana
    Jean-Paul Aben
    Kurian Thampi
    David Hewson
    Chris Sawh
    Richard Greenwood
    Marina Hughes
    Bahman Kasmai
    Liang Zhong
    Marcus Flather
    Vassilios S. Vassiliou
    Pankaj Garg
    European Radiology Experimental, 6
  • [7] Comparison of 2D and 4D Flow MRI Measurements for Hemodynamic Evaluation of the Fontan Palliation
    Listo, Elisa
    Martini, Nicola
    Salvadori, Stefano
    Valenti, Elisa
    Stagnaro, Nicola
    Trocchio, Gianluca
    Marrone, Chiara
    Clemente, Alberto
    Raimondi, Francesca
    Festa, Pierluigi
    Ali, Lamia Ait
    CONGENITAL HEART DISEASE, 2023, 18 (06) : 627 - 638
  • [8] In-vitro validation of 4D flow MRI measurements with an experimental pulsatile flow model
    David, A.
    Le Touze, D.
    Warin-Fresse, K.
    Paul-Gilloteaux, P.
    Bonnefoy, F.
    Idier, J.
    Moussaoui, S.
    Guerin, P.
    Serfaty, J-M
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2019, 100 (01) : 17 - 23
  • [9] Validation of the path integration of 4D dose distributions with 4D phantom measurements
    Zhang, GG
    Guerrero, TM
    Forster, K
    Fischer, G
    Fitzpatrick, M
    Starkschall, G
    Ibbott, G
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S608 - S609
  • [10] Global left ventricular function quantification with CMR 4D Flow
    Raluca G Saru
    Kevin Wanambiro
    Albert Hsiao
    Sara Boccalini
    Adriaan Coenen
    Ricardo Budde
    Piotr Wielopolski
    Shreyas Vasanawala
    Jolien Roos-Hesselink
    Koen Nieman
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)