Colorimetric RT-LAMP SARS-CoV-2 diagnostic sensitivity relies on color interpretation and viral load

被引:0
|
作者
Mateus Nóbrega Aoki
Bruna de Oliveira Coelho
Luiz Gustavo Bentim Góes
Paola Minoprio
Edison Luiz Durigon
Luis Gustavo Morello
Fabricio Klerynton Marchini
Irina Natassja Riediger
Maria do Carmo Debur
Helder I. Nakaya
Lucas Blanes
机构
[1] Carlos Chagas Institute,Laboratory for Applied Science and Technology in Health
[2] Oswaldo Cruz Foundation (Fiocruz),Departamento de Microbiologia – ICB‐II
[3] Scientific Platform Pasteur - University of São Paulo,Department of Clinical and Toxicological Analyses, School of Pharmaceutical Sciences
[4] Universidade de São Paulo,undefined
[5] University of São Paulo,undefined
[6] Paraná´s Central Laboratory (LACEN-PR),undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The use of RT-LAMP (reverse transcriptase—loop mediated isothermal amplification) has been considered as a promising point-of-care method to diagnose COVID-19. In this manuscript we show that the RT-LAMP reaction has a sensitivity of only 200 RNA virus copies, with a color change from pink to yellow occurring in 100% of the 62 clinical samples tested positive by RT-qPCR. We also demonstrated that this reaction is 100% specific for SARS-CoV-2 after testing 57 clinical samples infected with dozens of different respiratory viruses and 74 individuals without any viral infection. Although the majority of manuscripts recently published using this technique describe only the presence of two-color states (pink = negative and yellow = positive), we verified by naked-eye and absorbance measurements that there is an evident third color cluster (orange), in general related to positive samples with low viral loads, but which cannot be defined as positive or negative by the naked eye. Orange colors should be repeated or tested by RT-qPCR to avoid a false diagnostic. RT-LAMP is therefore very reliable for samples with a RT-qPCR Ct < 30 being as sensitive and specific as a RT-qPCR test. All reactions were performed in 30 min at 65 °C. The use of reaction time longer than 30 min is also not recommended since nonspecific amplifications may cause false positives.
引用
收藏
相关论文
共 50 条
  • [21] Colorimetric RT-LAMP Methods to Detect Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2)
    Park, Gun-Soo
    Baek, Seung-Hwa
    Ku, Keunbon
    Kim, Seong Jun
    Kim, Seung Il
    Kim, Bum-Tae
    Maeng, Jin-Soo
    BIO-PROTOCOL, 2020, 10 (21):
  • [22] Development of an optimized colorimetric RT-LAMP for SARS-CoV-2 assay with enhanced procedure controls for remote diagnostics
    Raddatz, Bruna Winkert
    Kim, Edson Yu Sin
    Imamura, Louise Matie
    Steil, Gisleine Jarenko
    Santiago, Erika Bergamo
    Soares, Santiago Pedro Timm
    Ribeiro, Victor Henrique Alves
    de Almeida, Bernardo Montesanti Machado
    Rogal Jr, Sergio Renato
    Figueredo, Marcus Vinicius Mazega
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [23] Development of an optimized colorimetric RT-LAMP for SARS-CoV-2 assay with enhanced procedure controls for remote diagnostics
    Bruna Winkert Raddatz
    Edson Yu Sin Kim
    Louise Matiê Imamura
    Gisleine Jarenko Steil
    Erika Bergamo Santiago
    Santiago Pedro Timm Soares
    Victor Henrique Alves Ribeiro
    Bernardo Montesanti Machado de Almeida
    Sergio Renato Rogal
    Marcus Vinícius Mazega Figueredo
    Scientific Reports, 12
  • [24] Rapid and Reliable Detection of SARS-CoV-2 Using Direct RT-LAMP
    El-Kafrawy, Sherif A.
    El-Daly, Mai M.
    Hassan, Ahmed M.
    Harakeh, Steve M.
    Alandijany, Thamir A.
    Azhar, Esam, I
    DIAGNOSTICS, 2022, 12 (04)
  • [25] Developing RT-LAMP assays for rapid diagnosis of SARS-CoV-2 in saliva
    Huang, Xin
    Tang, Gongyu
    Ismail, Nahed
    Wang, Xiaowei
    EBIOMEDICINE, 2022, 75
  • [26] Clinical validation of optimised RT-LAMP for the diagnosis of SARS-CoV-2 infection
    Boon Lim
    Jeremy Ratcliff
    Dorota A. Nawrot
    Yejiong Yu
    Harshmeena R. Sanghani
    Chia-Chen Hsu
    Leon Peto
    Simon Evans
    Susanne H. Hodgson
    Aikaterini Skeva
    Maria Adam
    Maria Panopoulou
    Christos E. Zois
    Katy Poncin
    Sridhar R. Vasudevan
    Siqi Dai
    Shuai Ren
    Hong Chang
    Zhanfeng Cui
    Peter Simmonds
    Wei E. Huang
    Monique I. Andersson
    Scientific Reports, 11
  • [27] Clinical validation of optimised RT-LAMP for the diagnosis of SARS-CoV-2 infection
    Lim, Boon
    Ratcliff, Jeremy
    Nawrot, Dorota A.
    Yu, Yejiong
    Sanghani, Harshmeena R.
    Hsu, Chia-Chen
    Peto, Leon
    Evans, Simon
    Hodgson, Susanne H.
    Skeva, Aikaterini
    Adam, Maria
    Panopoulou, Maria
    Zois, Christos E.
    Poncin, Katy
    Vasudevan, Sridhar R.
    Dai, Siqi
    Ren, Shuai
    Chang, Hong
    Cui, Zhanfeng
    Simmonds, Peter
    Huang, Wei E.
    Andersson, Monique I.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [28] Detection of SARS-CoV-2 RNA using RT-LAMP and molecular beacons
    Scott Sherrill-Mix
    Young Hwang
    Aoife M. Roche
    Abigail Glascock
    Susan R. Weiss
    Yize Li
    Leila Haddad
    Peter Deraska
    Caitlin Monahan
    Andrew Kromer
    Jevon Graham-Wooten
    Louis J. Taylor
    Benjamin S. Abella
    Arupa Ganguly
    Ronald G. Collman
    Gregory D. Van Duyne
    Frederic D. Bushman
    Genome Biology, 22
  • [29] Detection of SARS-CoV-2 RNA using RT-LAMP and molecular beacons
    Sherrill-Mix, Scott
    Hwang, Young
    Roche, Aoife M.
    Glascock, Abigail
    Weiss, Susan R.
    Li, Yize
    Haddad, Leila
    Deraska, Peter
    Monahan, Caitlin
    Kromer, Andrew
    Graham-Wooten, Jevon
    Taylor, Louis J.
    Abella, Benjamin S.
    Ganguly, Arupa
    Collman, Ronald G.
    Van Duyne, Gregory D.
    Bushman, Frederic D.
    GENOME BIOLOGY, 2021, 22 (01)
  • [30] Evaluation of SARS-CoV-2 RNA quantification by RT-LAMP compared to RT-qPCR
    Minami, Kenta
    Masutani, Ryota
    Suzuki, Youichi
    Kubota, Meri
    Osaka, Naofumi
    Nakanishi, Toyofumi
    Nakano, Takashi
    Ukimura, Akira
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2021, 27 (07) : 1068 - 1071