Whole-cell luminescence-based flow-through biodetector for toxicity testing

被引:0
|
作者
Philipp Stolper
Susanne Fabel
Michael G. Weller
Dietmar Knopp
Reinhard Niessner
机构
[1] Technische Universität München,Institut für Wasserchemie & Chemische Balneologie
[2] Federal Institute for Materials Research and Testing,undefined
来源
关键词
Biosensor; Air-segmented flow; Bioluminescence; Toxicity test;
D O I
暂无
中图分类号
学科分类号
摘要
A new type of biodetector was designed based on a bioluminescence test with the bacterium Vibrio fischeri performed in a liquid continuous flow-through system. Here we describe the modification of a commercial tube luminescence detector to work in the flow mode by building a new flow cell holder and a new case including “top cover” to connect the flow cell with the waste and the incubation capillary in a light-proof manner. As different samples were injected successively it was necessary to keep the individual peaks separated. This was done using an air-segmented flow in the reaction coil. To afford fast screening, the incubation time of the sample and the Vibrio fischeri, which equaled the dead time of the detection system, was set at 5.6 min. Rapid monitoring of toxic substances is achieved by using 20 μL of sample and flow-rates of 110–150 μL min−1. As a proof-of-principle, we show results for the detection of five selected di-, tri- and tetrachlorophenols at different concentrations varying from 1 to 200 mg L−1. Calculation of inhibition rates and EC50 values were performed and compared with corresponding values from the DIN EN ISO 11348-2 microplate format. Compared with the latter, the inhibition rates obtained with our flow-through biodetector for the compounds tested were generally about twofold lower, but importantly, a much faster detection is possible.
引用
收藏
页码:1181 / 1187
页数:6
相关论文
共 50 条
  • [41] APPARATUS FOR FLOW-THROUGH TESTING OF THE TOXIC EFFECT OF VOLATILE MATTER
    SOLDAN, P
    ROCEK, J
    LAZECKY, P
    ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 1991, 19 (05): : 507 - 515
  • [42] In Vitro Dissolution Testing with Flow-Through Method: A Technical Note
    Gao, Zongming
    AAPS PHARMSCITECH, 2009, 10 (04): : 1401 - 1405
  • [43] Towards toxicity detection using a lab-on-chip based on the integration of MOEMS and whole-cell sensors
    Elman, Noel M.
    Ben-Yoav, Hadar
    Sternheim, Marek
    Rosen, Rachel
    Krylov, Slava
    Shacham-Diamand, Yosi
    BIOSENSORS & BIOELECTRONICS, 2008, 23 (11): : 1631 - 1636
  • [44] In Vitro Dissolution Testing with Flow-Through Method: A Technical Note
    Zongming Gao
    AAPS PharmSciTech, 2009, 10 : 1401 - 1405
  • [45] FLOW-THROUGH NANOHOLE ARRAY BASED SENSING
    Escobedo, Carlos
    Wood, Paul
    Gordon, Reuven
    Brolo, Alexandre G.
    Sinton, David
    IMECE 2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 12, PTS A AND B, 2010, : 753 - 757
  • [46] Rapid flow-through enzyme immunoassay of progesterone in whole cows' milk
    Samsonova, Jeanne, V
    Safronova, Valentina A.
    Osipov, Alexander P.
    ANALYTICAL BIOCHEMISTRY, 2018, 545 : 43 - 48
  • [47] A FLOW-THROUGH ELECTROPORATION CHIP INTEGRATED WITH VIABLE CELL SORTING BASED ON DIELECTROPHORESIS
    Li, Xueming
    Wei, Zewen
    Zhao, Deyao
    Yan, Hao
    Liang, Zicai
    Li, Zhihong
    2012 IEEE 25TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2012,
  • [48] FLOW-THROUGH ONCOMETER SYSTEM FOR WHOLE-BLOOD IN EXPERIMENTAL USE
    PFEIFFER, U
    KOHLER, W
    BIRK, M
    BLUMEL, G
    EUROPEAN SURGICAL RESEARCH, 1979, 11 : 68 - 68
  • [49] Influence of flow-through and renewal exposures on the toxicity of copper to rainbow trout
    Welsh, Paul G.
    Lipton, Joshua
    Mebane, Christopher A.
    Marr, John C. A.
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2008, 69 (02) : 199 - 208
  • [50] Whole-Cell Photoacoustic Sensor Based on Pigment Relocalization
    Lauri, Antonella
    Soliman, Dominik
    Omar, Murad
    Stelzl, Anja
    Ntziachristos, Vasilis
    Westmeyer, Gil G.
    ACS SENSORS, 2019, 4 (03) : 603 - 612