Real-time monitoring of extracellular pH using a pH-potentiometric sensing SECM dual-microelectrode

被引:0
|
作者
Ranran Song
Qiang Xiong
Tao Wu
Xin Ning
Fan Zhang
Qingjiang Wang
Pingang He
机构
[1] East China Normal University,School of Chemistry and Molecular Engineering
来源
关键词
Scanning electrochemical microscopy; Dual-microelectrode; Extracellular pH; Potentiometric sensing; Real-time monitoring;
D O I
暂无
中图分类号
学科分类号
摘要
Extracellular pH can indicate the variation in organelle function and cell state. It is important to measure extracellular pH (pHe) with a controllable distance. In this work, a potentiometric SECM dual-microelectrode was developed to monitor the pHe of MCF-7 cells under electrical stimulation. The distance between the dual-microelectrode and the cells was determined first with a gold microelectrode by recording the approaching curve, and the pH was determined using an open-circuit potential (OCP) technique with a polyaniline-modified Pt microelectrode. The pH microelectrode showed a response slope of 53.0 ± 0.4 mV/pH and good reversibility from pH 4 to pH 8, fast response within 10 s, and a potential drift of 1.13% for 3 h, and thus was employed to monitor the pHe of stimulated cells. The value of pHe decreased with the decrease in the distance to cells, likely due to the release of H+. With an increase in the stimulation potential or time, the pHe value decreased, as the cell membrane became more permeable, which was verified by fluorescence staining of calcein-AM/PI (propidium iodide). Based on these results, this method can be widely applied for determining the species released by biosystems at a controllable position.
引用
收藏
页码:3737 / 3743
页数:6
相关论文
共 50 条
  • [41] Real-time monitoring of the pH microenvironment at the interface of multispecies biofilm and dental composites
    Nguyen, Anh Tuan
    Goswami, Subir
    Ferracane, Jack
    Koley, Dipankar
    ANALYTICA CHIMICA ACTA, 2022, 1201
  • [42] Real-Time Monitoring and Reporting Alarm System for pH Measurement in Wet Scrubbers
    Promsawat, Thipichpon
    Kummool, Sart
    Pongswatd, Sawai
    Julsereewong, Amphawan
    2016 16TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS), 2016, : 353 - 358
  • [43] Real-time monitoring of intracellular pH in live cells with fluorescent ionic liquid
    Gao, Lifang
    Lin, Xin
    Zheng, Anqi
    Shuang, E.
    Wang, Jianhua
    Chen, Xuwei
    ANALYTICA CHIMICA ACTA, 2020, 1111 : 132 - 138
  • [44] ISFET sensor system for real-time detection of extracellular pH oscillations in slime mould
    Nemeth, B.
    Tsuda, S.
    Busche, C.
    Cronin, L.
    Cumming, D. R. S.
    ELECTRONICS LETTERS, 2012, 48 (03) : 143 - U20
  • [45] Real-time monitoring of Ca2+and pH using a non-invasive wearable biosensor
    Nyein, Hnin
    Gao, Wei
    Javey, Ali
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [46] Development and Application of a New Mobile pH Calibrator for Real-Time Monitoring of pH in Diffuse Flow Hydrothermal Vent Fluids
    Tan, Chunyang
    Ding, Kang
    Seyfried, William E., Jr.
    MARINE TECHNOLOGY SOCIETY JOURNAL, 2016, 50 (02) : 37 - 47
  • [47] Using cone penetrometry to generate real-time eH/pH diagrams
    Rooney, DJ
    Timian, S
    IN SITU AND ON-SITE BIOREMEDIATION, VOL 2, 1997, 4(2) (02): : 405 - 405
  • [48] Robust and real-time monitoring of nerve regeneration using implantable flexible microelectrode array
    Kim, Yong-Ho
    Lee, Chungkeun
    Ahn, Kang-Min
    Lee, Myoungho
    Kim, Yong-Jun
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (07): : 1883 - 1887
  • [49] Real-time monitoring of the pH of white wine and beer with colorimetric sensor arrays (CSAs)
    Pastore, Andrea
    Badocco, Denis
    Cappellin, Luca
    Tubiana, Mauro
    Pastore, Paolo
    FOOD CHEMISTRY, 2024, 452
  • [50] REAL-TIME MONITORING OF DNA-POLYMERASE REACTIONS BY A MICRO ISFET PH SENSOR
    SAKURAI, T
    HUSIMI, Y
    ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1996 - 1997