摘要
Regenerator is major component of liquid desiccant regeneration system. The influence of operating parameters; air flow rate, solution flow rate and concentration of desiccant is investigated experimentaly on the performance parameters; outlet specific humidity, evaporation rate, air outlet temperature, mass transfer coefficient and effectiveness of the regenerator. Air and desiccant solution flow in counter direction with celdek pads as packing material. It is concluded that evaporation rate increases with increasing solution temperature, air flow rate and solution flow rate whereas same decreases with increasing concentration of desiccant. The effectiveness of regenerator is increased by 99 % with increase in air flow rate. A comparison of present finding with those available in the literature is presented in the last. Simulation results have revealed good agreement between the present experimental results.
引用
收藏
页码:4489 / 4498
页数:9
相关论文
共 50 条
  • [11] Modeling and performance of a forced flow solar collector/regenerator using liquid desiccant
    Alizadeh, S
    Saman, WY
    SOLAR ENERGY, 2002, 72 (02) : 143 - 154
  • [12] An experimental study of a forced flow solar collector/regenerator using liquid desiccant
    Alizadeh, S
    Saman, WY
    SOLAR ENERGY, 2002, 73 (05) : 345 - 362
  • [13] Performance investigation of a liquid desiccant regenerator with CFD technology
    Guo, Xiaodong
    Wen, Tao
    Wang, Meng
    Luo, Yimo
    She, Xiaohui
    APPLIED THERMAL ENGINEERING, 2021, 184
  • [14] Simplified model for packed-bed tower regenerator in a liquid desiccant system
    Kim, Min-Hwi
    Park, Joon-Young
    Jeong, Jae-Weon
    APPLIED THERMAL ENGINEERING, 2015, 89 : 717 - 726
  • [15] Performance study on the dehumidifier of a packed bed liquid desiccant system
    Salarian, H.
    Ghorbani, B.
    Amidpour, Majid
    Salehi, G.
    SCIENTIA IRANICA, 2014, 21 (01) : 222 - 228
  • [16] Study on performance of dehumidifier and regenerator of liquid desiccant cooling air conditioning system
    Yin, YG
    Zhang, XS
    Li, YL
    Wu, W
    Chen, ZQ
    Guan, ZS
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1274 - 1278
  • [17] A study on the regeneration performance characteristics of an internally heated regenerator in a liquid desiccant system
    Ji-Hyun Mun
    Dong-Soon Jeon
    Young-Lyoul Kim
    Seon-Chang Kim
    Journal of Mechanical Science and Technology, 2016, 30 : 1343 - 1349
  • [18] A study on the regeneration performance characteristics of an internally heated regenerator in a liquid desiccant system
    Mun, Ji-Hyun
    Jeon, Dong-Soon
    Kim, Young-Lyoul
    Kim, Seon-Chang
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2016, 30 (03) : 1343 - 1349
  • [19] Thermochemical Energy Storage in Low Flow Liquid Desiccant Regenerator
    Jaradat, Mustafa
    INTERNATIONAL ENERGY JOURNAL, 2019, 19 (03): : 159 - 176
  • [20] Thermochemical energy storage in low flow liquid desiccant regenerator
    Jaradat, Mustafa
    International Energy Journal, 2019, 19 (03): : 159 - 176