Automated oscillometric measurement of the ankle–brachial index in patients with coronary artery disease

被引:0
|
作者
Maciej Sinski
Grzegorz Styczynski
Cezary Szmigielski
机构
[1] Hypertension and Vascular Diseases,Department of the Internal Medicine
[2] The Medical University of Warsaw,undefined
来源
Hypertension Research | 2013年 / 36卷
关键词
ankle–brachial index; automated oscillometric method; coronary artery disease; doppler method; peripheral artery disease;
D O I
暂无
中图分类号
学科分类号
摘要
Automated oscillometric ankle–brachial index (ABI) devices were designed to measure ABI in a primary-care setting to increase the peripheral artery disease (PAD) detection rate. However, ABI measurements obtained with an automated oscillometric device may differ from those obtained using a standard ultrasound Doppler method in the general population. The purpose of this study was to compare PAD detection by the Doppler method and the automated WatchBP Office ABI system in a high-risk population with coronary artery disease (CAD). Eighty consecutive patients with confirmed CAD were included. ABI was measured by automated oscillometry followed by conventional Doppler evaluation. PAD was defined as an ABI⩽0.9. Each lower extremity was analyzed separately. The Doppler method detected an ABI⩽0.9 in 56 lower extremities, whereas the automated method detected an ABI⩽0.9 in 28 lower extremities (P<0.0001). A Bland–Altman plot showed poor agreement between the two methods. The mean ABI values obtained by the automated and Doppler methods were significantly different (1.11±0.20 vs. 0.95±0.24; P<0.00001). The sensitivity of the automated ABI device in detecting an ABI⩽0.9 was 46.3% and the specificity was 98.0%. The positive and negative predictive values for diagnosing an ABI⩽0.9 using the automated oscillometric method were 92.8% and 76.9%, respectively. In conclusion, the automated WatchBP Office ABI system should be used with caution for PAD detection and screening in patients with CAD, and this system should not replace the Doppler method in populations at high risk of cardiovascular disease.
引用
收藏
页码:25 / 28
页数:3
相关论文
共 50 条
  • [1] Automated oscillometric measurement of the ankle-brachial index in patients with coronary artery disease
    Sinski, Maciej
    Styczynski, Grzegorz
    Szmigielski, Cezary
    HYPERTENSION RESEARCH, 2013, 36 (01) : 25 - 28
  • [2] ANKLE- BRACHIAL INDEX MEASURED BY AN AUTOMATED OSCILLOMETRIC METHOD AS A PREDICTOR OF CARDIOVASCULAR EVENTS IN PATIENTS WITH CORONARY ARTERY DISEASE
    Lin, Tsung-Hsien
    Su, Ho-Ming
    Voon, Wen-Chol
    Lal, Wen-Ter
    Lee, Kun-Tai
    Chu, Chin-Sheng
    Sheu, Sheng-Hsiung
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 97 : S73 - S74
  • [3] The Accuracy and Reliability of Automated Oscillometric Measurement of Ankle-Brachial Index in the Diagnosis of Peripheral Artery Disease
    Fu, Guanqi
    Jiang, Rui
    Qian, Cheng
    Liu, Zhengli
    Kong, Jie
    Gong, Maofeng
    Wang, Tao
    He, Xu
    ANNALS OF VASCULAR SURGERY, 2024, 100 : 1 - 7
  • [4] Determination of lower extremity peripheral artery disease: the role for automated oscillometric measurement of ankle brachial index in Nigerians
    Umuerri, Ejiroghene M.
    CIRCULATION, 2012, 125 (19) : E795 - E795
  • [5] Validation of automated oscillometric versus manual measurement of the ankle–brachial index
    Tom Richart
    Tatiana Kuznetsova
    Barbara Wizner
    Harry A Struijker-Boudier
    Jan A Staessen
    Hypertension Research, 2009, 32 : 884 - 888
  • [6] Diagnostic accuracy of automated oscillometric determination of the ankle-brachial index in peripheral artery disease
    Hageman, David
    van den Houten, Marijn M. L.
    Pesser, Niels
    Gommans, Lindy N. M.
    Scheltinga, Marc R. M.
    Teijink, Joep A. W.
    JOURNAL OF VASCULAR SURGERY, 2021, 73 (02) : 652 - 660
  • [7] Oscillometric measurement of the ankle-brachial index
    MacDougall, Andrea M.
    Tandon, Vikas
    Wilson, Merne P.
    Wilson, Thomas W.
    CANADIAN JOURNAL OF CARDIOLOGY, 2008, 24 (01) : 49 - 51
  • [8] Concordance between automated oscillometric measurement of ankle-brachial index and traditional measurement by eco-Doppler in patients without peripheral artery disease
    Rodriguez-Roca, Gustavo C.
    Villarin-Castro, Alejandro
    Carrasco-Flores, Javier
    Artigao-Rodenas, Luis M.
    Carbayo-Herencia, Julio A.
    Escobar-Cervantes, Carlos
    Alonso-Moreno, Francisco J.
    Segura-Fragoso, Antonio
    Gomez-Serranillos, Manuel
    Hernandez-Moreno, Julio
    BLOOD PRESSURE, 2014, 23 (05) : 270 - 275
  • [9] Validation of automated oscillometric versus manual measurement of the ankle-brachial index
    Richart, T.
    Kouznetsova, T.
    Wizner, B.
    Struijker-Boudier, H.
    Staessen, J.
    JOURNAL OF HYPERTENSION, 2008, 26 : S499 - S499
  • [10] Validation of automated oscillometric versus manual measurement of the ankle-brachial index
    Richart, Tom
    Kuznetsova, Tatiana
    Wizner, Barbara
    Struijker-Boudier, Harry A.
    Staessen, Jan A.
    HYPERTENSION RESEARCH, 2009, 32 (10) : 884 - 888