Diagnostic accuracy of automated oscillometric determination of the ankle-brachial index in peripheral artery disease

被引:13
|
作者
Hageman, David [1 ,2 ]
van den Houten, Marijn M. L. [1 ,2 ]
Pesser, Niels [1 ]
Gommans, Lindy N. M. [1 ]
Scheltinga, Marc R. M. [3 ]
Teijink, Joep A. W. [1 ,2 ]
机构
[1] Catharina Hosp, Dept Vasc Surg, POB 1350, NL-5602 ZA Eindhoven, Netherlands
[2] Maastricht Univ, CAPHRI Sch Publ Hlth & Primary Care, Fac Hlth Med & Life Sci, Dept Epidemiol, Maastricht, Netherlands
[3] Maxima Med Ctr, Dept Vasc Surg, Veldhoven, Netherlands
关键词
Peripheral artery disease; Intermittent claudication; Ankle-brachial index; Blood pressure; Oscillometry; Doppler; PRESSURE; DOPPLER; GUIDELINES; AGREEMENT; SOCIETY; ABI;
D O I
10.1016/j.jvs.2020.05.077
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Peripheral artery disease (PAD) is underdiagnosed in primary care settings, partly because of limited accuracy of the Doppler ankle-brachial index (ABI). This study aimed to assess the diagnostic accuracy of an automated oscillometric ABI device compared with reference standard vascular laboratory Doppler ABI equipment and to examine the influence of oscillometric errors on performance. Methods: Consecutive patients who were referred to a large general hospital for an ABI measurement were invited to participate. In each patient, the oscillometric analysis was followed by the Doppler analysis. Legs with incompressible ankle arteries were excluded from analysis. ABI values were compared using the Bland-Altman method. Oscillometric errors were defined as the incapacity of the oscillometer to report a value of ABI. A receiver operating characteristic curve was constructed, and the area under the curve was computed. Results: A total of 201 patients participated. The Bland-Altman plot showed a mean difference of 0.05 +/- 0.12 (limits of agreement, -0.20 to 0.29), representing a small ABI overestimation after oscillometry. Oscillometric errors occurred more commonly in limbs with PAD than in limbs without PAD (28% and 7%, respectively; P < .001). Considering a 0.9 threshold and after oscillometric error exclusion, the oscillometric ABI showed a 74% sensitivity and a 97% specificity for a diagnosis of PAD. When oscillometric errors were considered as abnormal ABIs, sensitivity increased to 86% and specificity was maintained at 95%. The receiver operating characteristic curve showed an area under the curve of 0.96. The best oscillometric ABI cutoff point was 1.00. Using this threshold and when considering oscillometric errors as abnormal ABIs, sensitivity improved to 94% while maintaining specificity at 92%. Conclusions: Oscillometric ABI showed good diagnostic accuracy compared with the reference standard. However, the high incidence of oscillometric errors and the challenges to correctly interpret readings may limit the use of the oscillometric method in PAD diagnosis.
引用
收藏
页码:652 / 660
页数:9
相关论文
共 50 条
  • [1] Accuracy of oscillometric determination of the ankle-brachial index as screening method for peripheral artery disease
    Campens, Laurence
    De Backer, Tine
    Simoens, Steven
    Vermassen, Frank
    Coeman, Mathieu
    De Pauw, Michel
    De Bacquer, Dirk
    [J]. ACTA CARDIOLOGICA, 2012, 67 (01) : 136 - 137
  • [2] The Accuracy and Reliability of Automated Oscillometric Measurement of Ankle-Brachial Index in the Diagnosis of Peripheral Artery Disease
    Fu, Guanqi
    Jiang, Rui
    Qian, Cheng
    Liu, Zhengli
    Kong, Jie
    Gong, Maofeng
    Wang, Tao
    He, Xu
    [J]. ANNALS OF VASCULAR SURGERY, 2024, 100 : 1 - 7
  • [3] 12.15: Accuracy of Oscillometric Determination of the Ankle-Brachial Index as Screening Method for Peripheral Artery Disease
    L. Campens
    T. De Backer
    S. Simoens
    F. Vermassen
    M. Coeman
    M. De Pauw
    D. De Bacquer
    [J]. Artery Research, 2011, 5 (4) : 204 - 204
  • [4] Automated oscillometric measurement of the ankle-brachial index in patients with coronary artery disease
    Sinski, Maciej
    Styczynski, Grzegorz
    Szmigielski, Cezary
    [J]. HYPERTENSION RESEARCH, 2013, 36 (01) : 25 - 28
  • [5] Diagnostic Accuracy Study of an Oscillometric Ankle-Brachial Index in Peripheral Arterial Disease: The Influence of Oscillometric Errors and Calcified Legs
    Herraiz-Adillo, Angel
    Martinez-Vizcaino, Vicente
    Cavero-Redondo, Ivan
    Alvarez-Bueno, Celia
    Garrido-Miguel, Miriam
    Notario-Pacheco, Blanca
    [J]. PLOS ONE, 2016, 11 (11):
  • [6] Determination of Peripheral Artery Disease using Ankle-Brachial Index
    Kumar, P. V. L. Anjani
    Sindhura, P.
    Chaitanya, S.
    Prabhakar, D.
    Narender, Boggula
    Bakshi, Vasudha
    [J]. ASIAN JOURNAL OF PHARMACEUTICS, 2018, 12 (04) : S1345 - S1355
  • [7] Validity and reliability of the ankle-brachial index by oscillometric blood pressure and automated ankle-brachial index
    Chongthawonsatid, Sukanya
    Dutsadeevettakul, Somchai
    [J]. JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2017, 22
  • [8] Ankle-Brachial Index determination and peripheral arterial disease diagnosis by an oscillometric blood pressure device in primary care: validation and diagnostic accuracy study
    Nelson, Mark R.
    Quinn, Stephen
    Winzenberg, Tania M.
    Howes, Faline
    Shiel, Louise
    Reid, Christopher M.
    [J]. BMJ OPEN, 2012, 2 (05):
  • [9] Novel oscillometric-based algorithm for diagnosis of peripheral artery disease (PAD) and determination of the ankle-brachial index (ABI)
    Gornik, Heather L.
    Nacion, Kristine M.
    Grattan, Alia
    Jones, David C.
    Jarrell, Ken
    Na, Jie
    Wang, Xiaofeng
    [J]. VASCULAR MEDICINE, 2011, 16 (03) : 225 - 225
  • [10] Determination of lower extremity peripheral artery disease: the role for automated oscillometric measurement of ankle brachial index in Nigerians
    Umuerri, Ejiroghene M.
    [J]. CIRCULATION, 2012, 125 (19) : E795 - E795