Anisoplanatic turbulence correction in incoherent imaging by using reference sources with different wavelengths

被引:13
|
作者
Dudorov V.V. [1 ]
Kolosov V.V. [1 ]
机构
[1] V.E. Zuev Institute of Atmospheric Optics, Siberian Branch, Russian Academy of Sciences, pl. Akademika Zueva 1, Tomsk
关键词
Point Spreading Function; Image Enhancement; Phase Correction; Exposure Image; Phase Compensation;
D O I
10.1134/S1024856010050039
中图分类号
学科分类号
摘要
The possibility of the phase compensation of turbulent distortions of incoherent images of an object illuminated by radiation with different wavelengths is investigated. The research is carried out based on the method that is a further improvement of the algorithm for the numerical simulation of incoherent imaging through the atmosphere in conditions of anisoplanatic turbulence developed by the authors [Lachinova S.L., Vorontsov M.A., Dudorov V.V., Kolosov V.V., Valley M.T. // Proc. SPIE. 2007. V. 6708. 67080E]. The dependence of the degree and region of the enhancement of the image on the ratio of the reference wavelength to the image-forming radiation one is shown. © 2010, Pleiades Publishing, Ltd.
引用
收藏
页码:353 / 358
页数:5
相关论文
共 46 条
  • [31] TOMOGRAPHIC IMAGING OF THE CHEST USING COMPTON-SCATTERING AND IR-192 SOURCES - PERFORMANCE AND ATTENUATION CORRECTION
    GUZZARDI, R
    ZITO, M
    MEY, M
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1981, 22 (06) : P68 - P68
  • [32] Correction to: Synthesis, characterization, and electrochemical performance of Cu3SbS3 using different sources of sulfur
    Atef Y. Shenouda
    Marwa M. Moharam
    Fatma E. Farghaly
    [J]. Journal of Materials Science: Materials in Electronics, 2024, 35 (5)
  • [33] A novel peptide-based fluorescent chemosensor for measuring zinc ions using different excitation wavelengths and application in live cell imaging
    Wang, Peng
    Wu, Jiang
    Zhou, Panpan
    Liu, Weisheng
    Tang, Yu
    [J]. JOURNAL OF MATERIALS CHEMISTRY B, 2015, 3 (17) : 3617 - 3624
  • [34] SENSING REFRACTIVE-TURBULENCE PROFILES (C-N(2)) USING WAVE-FRONT PHASE MEASUREMENTS FROM MULTIPLE REFERENCE SOURCES
    WELSH, BM
    [J]. APPLIED OPTICS, 1992, 31 (34) : 7283 - 7291
  • [35] Scan Time Reduction in Intravoxel Incoherent Motion Diffusion-Weighted Imaging and Diffusion Kurtosis Imaging of the Abdominal Organs: Using a Simultaneous Multislice Technique With Different Acceleration Factors
    Xu, Hui
    Zhang, Nan
    Yang, Da-Wei
    Ren, Ahong
    Ren, Hao
    Zhang, Qian
    Zhu, Jin-Xia
    Li, Gui-Jin
    Yang, Zheng-Han
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (04) : 507 - 515
  • [36] Alignment Monitor for Free-Space Optical Links in the Presence of Turbulence using the Beating of Opposite-Order Orbital-Angular-Momentum Beams on Two Different Wavelengths
    Zhang, Runzhou
    Hu, Nanzhe
    Su, Xinzhou
    Almaiman, Ahmed
    Song, Haoqian
    Zhao, Zhe
    Song, Hao
    Pang, Kai
    Liu, Cong
    Tur, Moshe
    Willner, Alan E.
    [J]. 2020 OPTICAL FIBER COMMUNICATIONS CONFERENCE AND EXPOSITION (OFC), 2020,
  • [37] Identification and validation of reference genes to study the gene expression in Gluconacetobacter diazotrophicus grown in different carbon sources using RT-qPCR
    Galisa, Pericles S.
    da Silva, Helder A. P.
    Macedo, Aline V. M.
    Reis, Veronica M.
    Vidal, Marcia S.
    Baldani, Jose I.
    Simoes-Araujo, Jean L.
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2012, 91 (01) : 1 - 7
  • [38] Different hemodynamics of basal ganglia between moyamoya and non-moyamoya diseases using intravoxel incoherent motion imaging and single-photon emission computed tomography
    Yamashita, Koji
    Sugimori, Hiroshi
    Nakamizo, Akira
    Amano, Toshiyuki
    Kuwashiro, Takahiro
    Watanabe, Takeharu
    Kawamata, Keisuke
    Furuya, Kiyomi
    Harada, Shino
    Kamei, Ryotaro
    Maehara, Junki
    Okada, Yasushi
    Noguchi, Tomoyuki
    [J]. ACTA RADIOLOGICA, 2023, 64 (02) : 769 - 775
  • [39] In-vivo and ex-vivo parathyroid autofluorescence overlay imaging is equally feasible using two different wavelengths (785 nm vs. 805 nm)
    Arikan, M.
    Hargitai, L.
    Binter, T.
    Scheuba, C.
    Riss, P.
    [J]. CURRENT PROBLEMS IN SURGERY, 2024, 61 (03)
  • [40] Diffusion-Weighted MR Imaging of Upper Abdominal Organs at Different Time Points: Apparent Diffusion Coefficient Normalization Using a Reference Organ
    Song, Ji Soo
    Kwak, Hyo Sung
    Byon, Jung Hee
    Yong, Gong
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (05) : 1494 - 1501