In-situ and highly sensitive detection of epidermal growth factor receptor mutation using nano-porous quartz crystal microbalance

被引:0
|
作者
Hyunjun Park
Juneseok You
Chanho Park
Kuewhan Jang
Sungsoo Na
机构
[1] Korea University,Department of Mechanical Engineering
[2] Hoseo University,School of Mechanical Engineering
关键词
Epidermal growth factor receptor (EGFR); In-situ detection; Mutation; Nano-porous; Quartz crystal microbalance (QCM);
D O I
暂无
中图分类号
学科分类号
摘要
Assessment of epidermal growth factor receptor (EGFR) exon 19 mutations is very important indicator for treating lung cancer patients. In this report, we propose in-situ and highly sensitive detection method of EGFR mutation using quartz crystal microbalance (QCM) and nano-porous structured QCM electrode. The detection is based on the resonance frequency shift of QCM electrode upon DNA hybridization between probe DNA and EGFR mutant DNA (746–750 (del ELREA) in EGFR exon 19). Nano-porous structure is produced on the QCM electrode through simple processes of electrochemical deposition and etching. By using QCM, in-situ detection of EGFR mutation is performed within 30 mins. High sensitivity is achieved by introducing nano-porous structure on a QCM electrode, and the limit of detection (LOD) is 1 nM.
引用
收藏
页码:1927 / 1932
页数:5
相关论文
共 50 条
  • [21] DIRECT IN-SITU MEASUREMENT OF PHOSPHOLIPID HYDRATION IN AN AQUEOUS ENVIRONMENT USING A QUARTZ-CRYSTAL MICROBALANCE
    WAKAMATSU, K
    HOSODA, K
    MITOMO, H
    OHYA, M
    OKAHATA, Y
    YASUNAGA, K
    ANALYTICAL CHEMISTRY, 1995, 67 (18) : 3336 - 3341
  • [22] A reusable quartz crystal microbalance biosensor for highly specific detection of single-base DNA mutation
    Wang, Dingzhong
    Chen, Gengjia
    Wang, Huaming
    Tang, Wei
    Pan, Wei
    Li, Na
    Liu, Feng
    BIOSENSORS & BIOELECTRONICS, 2013, 48 : 276 - 280
  • [23] In-situ growth of CdS QDs on ZnO porous microrods for highly sensitive detection of TEA at lower temperature
    Cheng, Lianyun
    Li, Yanwei
    Sun, Guang
    Cao, Jianliang
    Wang, Yan
    VACUUM, 2023, 212
  • [24] Stimulated mass enhancement strategy-based highly sensitive detection of a protein in serum using quartz crystal microbalance technique
    Akter, Rashida
    Jeong, Bongjin
    Rahman, Md Aminur
    ANALYST, 2015, 140 (04) : 995 - 998
  • [25] RAPID COLORIMETRIC DETECTION OF EPIDERMAL GROWTH-FACTOR RECEPTOR MESSENGER-RNA BY IN-SITU HYBRIDIZATION
    LEZZONI, JC
    KANG, JH
    BUCANA, CD
    REED, JA
    BRIGATI, DJ
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1993, 7 (05) : 247 - 251
  • [26] Sensitive Detection of β-Myrcene in Mango Using Ethyl Cellulose Modified Quartz Crystal Microbalance Sensor
    Ali, Sk Babar
    Ghatak, Barnali
    Debabhuti, Nilava
    Pal, Satyaki
    Sharma, Prolay
    Tudu, Bipan
    Bandyopadhyay, Rajib
    MATERIALS TODAY-PROCEEDINGS, 2019, 18 : 1025 - 1032
  • [27] A rapid and sensitive enzymatic method for epidermal growth factor receptor mutation screening
    Jänne, PA
    Borras, AM
    Kuang, YN
    Rogers, AM
    Joshi, VA
    Liyanage, H
    Lindeman, N
    Lee, JC
    Halmos, B
    Maher, EA
    Distel, RJ
    Meyerson, M
    Johnson, BE
    CLINICAL CANCER RESEARCH, 2006, 12 (03) : 751 - 758
  • [28] Mutation of epidermal growth factor receptor in hormone sensitive and refractory prostate cancers
    Lee, J. S.
    Choi, Y. D.
    Kim, K. T.
    EJC SUPPLEMENTS, 2007, 5 (04): : 284 - 284
  • [29] Highly sensitive detection of silver ions using a silver-specific DNA based nano-porous micro-resonator
    Jang, Kuewhan
    You, Juneseok
    Park, Chanho
    Na, Sungsoo
    NEW JOURNAL OF CHEMISTRY, 2017, 41 (04) : 1840 - 1845
  • [30] Study on a highly sensitive determination method for protein in aqueous solution using a quartz-crystal microbalance
    Matsuura, H
    Mizutani, F
    Hasebe, Y
    Uchiyama, S