Absence of flexor carpi radialis identified during volar approach for fixation of distal radius fracture: A case report

被引:2
|
作者
Irie T. [1 ]
Motomiya M. [1 ,2 ]
Iwasaki N. [1 ]
机构
[1] Department of Orthopaedic Surgery, Faculty of Medicine, Graduate School of Medicine, Hokkaido University, Sapporo
[2] Department of Orthopaedic Surgery, Obihiro Kosei Hospital, Nishi 6 Minami 8-1, Obihiro
关键词
Anomaly; Distal radius fracture; Flexor carpi radialis; Flexor carpi radialis brevis; Volar approach;
D O I
10.1186/s13104-018-3348-z
中图分类号
学科分类号
摘要
Background: Volar locking plate fixation of distal radius fractures is commonly performed because of its good clinical outcomes. The flexor carpi radialis (FCR) approach is one of the most popular approaches to dissecting the volar side of the distal radius because of its simplicity and safety. We describe an extremely rare case of an absent FCR identified during a volar approach for fixation of a distal radius fracture. Case presentation: A 59-year-old woman with distal radius fracture underwent surgery using the usual FCR approach and volar locking plate. We could not identify the absence of the FCR tendon preoperatively because of severe swelling of the distal forearm. At first, we wrongly identified the palmaris longus tendon as the FCR because it was the tendinous structure at the most radial location of the volar distal forearm. When we found the median nerve just radial to the palmaris longus tendon, we were then able to identify the anatomical abnormality in this case. To avoid iatrogenic neurovascular injuries, we changed the approach to the classic Henry's approach. Conclusions: Although the FCR approach is commonly used for fixation of distal radius fractures because of its simplicity and safety, this is the first report of complete absence of the FCR during the commonly performed volar approach for fixation of a distal radius fracture, to our knowledge. Because the FCR is designated as a favorable landmark because of its superficially palpable location, strong and thick structure, and rare anatomical variations, there is the possibility of iatrogenic complications in cases of the absence of the FCR. We suggest that surgeons should have a detailed knowledge of the range of possible anomalies to complete the fixation of a distal radius fracture safely. © 2018 The Author(s).
引用
收藏
相关论文
共 50 条
  • [31] Bilateral Flexor Carpi Radialis Brevis and Unilateral Flexor Carpi Ulnaris Brevis Muscle: Case Report
    Chong, Simon Jeffery
    Al-Ani, Sami
    Pinto, Clinton
    Peat, Bruce
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (10): : 1868 - 1871
  • [32] The Role of Proximal Locking Fixation in Volar Distal Radius Fracture Fixation
    Gossett, Leland
    Vu, Giap H.
    Reizner, Wayne
    Gira, Emma
    Qiu, Bowen
    Awad, Hani A.
    Ketonis, Constantinos
    JOURNAL OF WRIST SURGERY, 2024,
  • [33] Headless Bone Screw Fixation for Combined Volar Lunate Facet Distal Radius Fracture and Capitate Fracture: Case Report
    Waters, Michael J.
    Ruchelsman, David E.
    Belsky, Mark R.
    Leibman, Matthew I.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (08): : 1489 - 1493
  • [34] DELAYED RUPTURE OF FLEXOR TENDONS CAUSED BY PROTRUSION OF A SCREW HEAD OF A VOLAR PLATE FOR DISTAL RADIUS FRACTURE: A CASE REPORT
    Yamazaki, Hiroshi
    Hattori, Yasunori
    Doi, Kazuteru
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2008, 13 (01): : 27 - 29
  • [35] Letter Regarding "Volar Plate Position and Flexor Tendon Rupture Following Distal Radius Fracture Fixation" Reply
    Afshar, Ahmadreza
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (11): : 2303 - 2304
  • [36] Trigger thumb preceding flexor pollicis longus tendon rupture after distal radius volar plate fixation: A case report
    Dbeis, Ammer
    Ngo, John
    Chiang, Emerald
    Ishak, Andre
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2022, 94
  • [37] Rupture of flexor tendon following volar plate of distal radius fracture. Report of five cases
    Valbuena, S. E.
    Cogswell, L. K.
    Baraziol, R.
    Valenti, P.
    CHIRURGIE DE LA MAIN, 2010, 29 (02) : 109 - 113
  • [38] The flexor carpi radialis brevis muscle: An anomalous flexor of the wrist and hand. A case report
    Kang, Lana
    Carter, Timothy
    Wolfe, Scott W.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (09): : 1511 - 1513
  • [39] The Flexor Carpi Radialis Portal for Arthroscopy-Assisted Reduction of the Dorsal Ulnar Fragment in Distal Radius Fractures
    de Oliveira, Ricardo Kaempf
    Farina Brunelli, Joao Pedro
    Aita, Marcio Aurelio
    Delgado Serrano, Pedro Jose
    JOURNAL OF WRIST SURGERY, 2023, 12 (01) : 63 - 66
  • [40] Functional Outcome of Volar Locking Plate Fixation in Distal Radius Fracture
    Raza, Shahid
    Raza, Sibtain
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2018, 12 (01): : 330 - 333