Magnetic resonance imaging of atherosclerotic lesion with new devised animal surface coil

被引:2
|
作者
Zhao B.-H. [1 ]
Li M.-H. [1 ]
Zhao Q. [2 ]
Cheng Y.-S. [1 ]
Xiao Y.-F. [1 ]
Zhao J.-M. [3 ]
机构
[1] Radiology Department, Shanghai 6th People's Hospital, Shanghai Jiaotong University
[2] Cardiology Department, Shanghai 6th People's Hospital, Shanghai Jiaotong University
[3] Shanghai Chenguang Medical Technology Company
关键词
Atherosclerotic plaque; Magnetic resonance imaging; Multi-detector CT; Surface coil;
D O I
10.1007/s12204-008-0748-6
中图分类号
学科分类号
摘要
The ability of dynamic contrast enhanced magnetic resonance imaging (DCE MRI) with a new devised animal surface coil was analyzed in identifying atherosclerotic plaques in the rabbit medium-sized iliac artery (IA). Then a comparative analysis of multi-detector computed tomography (MDCT) and DCE MRI was done in discerning morphology and components of 80 atherosclerotic plaques identified by histopathology. It shows that the DCE MRI may be an emerging noninvasive and economic way to characterize atherosclerotic plaques at present. What's more, a new devised animal surface coil would further improve the signal-to-noise ratio (SNR) and the quality of imaging. However, CT angiography (CTA) may be better than MR angiography(MRA) in detecting vessel stenosis. Copyright.
引用
收藏
页码:748 / 752
页数:4
相关论文
共 50 条
  • [31] Reproducibility of carotid atherosclerotic lesion type determination using high-resolution magnetic resonance imaging
    Chu, B
    Hatsukami, TS
    Zhao, X
    Polissar, NL
    Waterton, JC
    Raichlen, J
    Hamar, W
    Yuan, C
    ATHEROSCLEROSIS SUPPLEMENTS, 2003, 4 (02) : 253 - 253
  • [32] Surface receive coil dedicated for rat kidney with high sensitivity magnetic resonance imaging
    Takahashi, Masaharu
    Fushimi, Motofumi
    Yabukami, Shin
    Sekino, Masaki
    Kuwahata, Akihiro
    AIP ADVANCES, 2024, 14 (01)
  • [33] Transceive surface coil array for magnetic resonance imaging of the human brain at 4 T
    Pinkerton, RG
    Barberi, EA
    Menon, RS
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 499 - 503
  • [34] Two-slotted surface coil array for magnetic resonance imaging at 4 tesla
    Solis, S. E.
    Hernandez, J. A.
    Tomasi, D.
    Rodriguez, A. O.
    MEDICAL PHYSICS, 2008, 1032 : 152 - +
  • [35] Pelvic varices diagnosed with endorectal surface coil magnetic resonance imaging: case report
    Gullo, G
    Russ, PD
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2000, 51 (01): : 23 - 27
  • [36] Petal resonator surface coil with a circular envelope for high field magnetic resonance imaging
    Hidalgo, S. S.
    Cuellar, G.
    Solis, S. E.
    Alejski, A.
    Rodriguez, A. O.
    MEDICAL PHYSICS, 2008, 1032 : 225 - 228
  • [37] SURFACE-COIL MAGNETIC-RESONANCE IMAGING OF THE INTERNAL AUDITORY-CANAL
    DANIELS, DL
    SCHENCK, JF
    FOSTER, T
    HART, H
    MILLEN, SJ
    MEYER, GA
    PECH, P
    SHAFFER, KA
    HAUGHTON, VM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1985, 6 (04) : 487 - 490
  • [38] Magnetic resonance imaging of the prostate with spectroscopic imaging using a surface coil. Initial clinical experience
    Manenti, G
    Squillaci, E
    Carlani, M
    Mancino, S
    Di Roma, M
    Simonetti, G
    RADIOLOGIA MEDICA, 2006, 111 (01): : 22 - 32
  • [39] SURFACE-COIL MAGNETIC-RESONANCE IMAGING OF THE INTERNAL AUDITORY-CANAL
    DANIELS, DL
    SCHENCK, JF
    FOSTER, T
    HART, H
    MILLEN, SJ
    MEYER, GA
    PECH, P
    SHAFFER, KA
    HAUGHTON, VM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 145 (03) : 469 - 472
  • [40] Improving cerebral cortical magnetic resonance imaging using a readily available surface coil
    Gomez-Hassan, DM
    Blaesing, C
    Shattock, S
    Chenevert, TL
    JOURNAL OF NEUROIMAGING, 2004, 14 (03) : 231 - 234