Magnetic resonance imaging of atherosclerotic lesion with new devised animal surface coil

被引:2
|
作者
Zhao B.-H. [1 ]
Li M.-H. [1 ]
Zhao Q. [2 ]
Cheng Y.-S. [1 ]
Xiao Y.-F. [1 ]
Zhao J.-M. [3 ]
机构
[1] Radiology Department, Shanghai 6th People's Hospital, Shanghai Jiaotong University
[2] Cardiology Department, Shanghai 6th People's Hospital, Shanghai Jiaotong University
[3] Shanghai Chenguang Medical Technology Company
关键词
Atherosclerotic plaque; Magnetic resonance imaging; Multi-detector CT; Surface coil;
D O I
10.1007/s12204-008-0748-6
中图分类号
学科分类号
摘要
The ability of dynamic contrast enhanced magnetic resonance imaging (DCE MRI) with a new devised animal surface coil was analyzed in identifying atherosclerotic plaques in the rabbit medium-sized iliac artery (IA). Then a comparative analysis of multi-detector computed tomography (MDCT) and DCE MRI was done in discerning morphology and components of 80 atherosclerotic plaques identified by histopathology. It shows that the DCE MRI may be an emerging noninvasive and economic way to characterize atherosclerotic plaques at present. What's more, a new devised animal surface coil would further improve the signal-to-noise ratio (SNR) and the quality of imaging. However, CT angiography (CTA) may be better than MR angiography(MRA) in detecting vessel stenosis. Copyright.
引用
收藏
页码:748 / 752
页数:4
相关论文
共 50 条
  • [1] Magnetic Resonance Imaging of Atherosclerotic Lesion with New Devised Animal Surface Coil
    赵炳辉
    李明华
    赵清
    程英升
    肖云峰
    赵家民
    Journal of Shanghai Jiaotong University(Science), 2008, 13 (06) : 748 - 752
  • [2] Surface Coil for Magnetic Resonance Imaging
    Ricardo Ferro, Beatriz Taimy
    Ramirez Aguilera, Andres
    Alvarez Guerra, Eloy Daniel
    REVISTA CUBANA DE INGENIERIA, 2015, 6 (01): : 13 - 21
  • [3] SURFACE COIL MAGNETIC-RESONANCE IMAGING
    AXEL, L
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (03) : 381 - 384
  • [4] SURFACE COIL MAGNETIC-RESONANCE IMAGING
    EDELSTEIN, WA
    SCHENCK, JF
    HART, HR
    HARDY, CJ
    FOSTER, TH
    BOTTOMLEY, PA
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1985, 253 (06): : 828 - 828
  • [5] SURFACE COIL MAGNETIC-RESONANCE-IMAGING
    AXEL, L
    HAYES, C
    ARCHIVES INTERNATIONALES DE PHYSIOLOGIE DE BIOCHIMIE ET DE BIOPHYSIQUE, 1985, 93 (05): : 11 - 18
  • [6] Use of magnetic resonance imaging to assess carotid atherosclerotic lesion distribution
    Chu, B
    Hatsukami, TS
    Polissar, NL
    Zhao, X
    Kraiss, LW
    Parker, D
    Waterton, JC
    Raichlen, J
    Hamar, W
    Yuan, C
    ATHEROSCLEROSIS SUPPLEMENTS, 2003, 4 (02) : 253 - 253
  • [7] New magnetic resonance imaging of esophageal cancer using an endoluminal surface coil.
    Ozawa, S
    Imai, Y
    Ando, N
    Ueda, M
    Kitajima, M
    GASTROENTEROLOGY, 1996, 110 (04) : A573 - A573
  • [8] SURFACE COIL MAGNETIC-RESONANCE-IMAGING OF THE FETAL BRAIN
    REVEL, MP
    PONS, JC
    LELAIDIER, C
    VIAL, M
    FRYDMAN, R
    MUSSET, D
    LABRUNE, M
    LANCET, 1992, 340 (8812): : 176 - 176
  • [9] SURFACE COIL MAGNETIC-RESONANCE-IMAGING OF THE NORMAL LARYNX
    MCARDLE, CB
    BAILEY, BJ
    AMPARO, EG
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1986, 112 (06) : 616 - 622
  • [10] Staging of cervical carcinomas - Comparison of body-coil magnetic resonance imaging and endorectal surface coil magnetic resonance imaging with histopathologic correlation
    Preidler, KW
    Tamussino, K
    Szolar, DM
    Ranner, G
    Ebner, F
    INVESTIGATIVE RADIOLOGY, 1996, 31 (07) : 458 - 462