Determination of a flame retardant hydrolysis product in human urine by SPE and LC–MS. Comparison of molecularly imprinted solid-phase extraction with a mixed-mode anion exchanger

被引:0
|
作者
Kristina Möller
Carlo Crescenzi
Ulrika Nilsson
机构
[1] Stockholm University,Department of Analytical Chemistry
来源
关键词
Molecularly imprinted polymers; Solid-phase extraction; Urine samples; LC–MS; Organophosphate esters;
D O I
暂无
中图分类号
学科分类号
摘要
Diphenyl phosphate is a hydrolysis product and possible metabolite of the flame retardant and plasticiser additive triphenyl phosphate. A molecularly imprinted polymer solid-phase extraction (MISPE) method for extracting diphenyl phosphate from aqueous solutions has been developed and compared with SPE using a commercially available mixed-mode anion exchanger. The imprinted polymer was prepared using 2-vinylpyridine (2-Vpy) as the functional monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linker, and a structural analogue of the analyte as the template molecule. The imprinted polymer was evaluated for use as a SPE sorbent, in tests with both aqueous standards and spiked urine samples, by comparing recovery and breakthrough data obtained using the imprinted form of the polymer and a non-imprinted form (NIP). Extraction from aqueous solutions resulted in more than 80% recovery. Adsorption by the molecularly imprinted polymer (MIP) was non-selective , but selectivity was achieved by selective desorption in the wash steps. Diphenyl phosphate could also be selectively extracted from urine samples, although the urine matrix reduced the capacity of the MISPE cartridges. Recoveries from urine extraction were higher than 70%. It was important to control pH during sample loading. The MISPE method was found to yield a less complex LC–ESI–MS chromatogram of the urine extracts compared with the mixed-mode anion-exchanger method. An LC–ESI–MS method using a Hypercarb LC column with a graphitised carbon stationary phase was also evaluated for organophosphate diesters. LC–ESI–MS using negative-ion detection in selected ion monitoring (SIM) mode was shown to be linear for diphenyl phosphate in the range 0.08–20 ng μL−1.
引用
收藏
页码:197 / 204
页数:7
相关论文
共 50 条
  • [41] A novel mixed-mode solid phase extraction coupled with LC-MS/MS for the re-evaluation of free 3-nitrotyrosine in human plasma as an oxidative stress biomarker
    Li, Xiaoguang
    Li, Shu
    Kellermann, Gottfried
    TALANTA, 2015, 140 : 45 - 51
  • [42] Simultaneous determination of levofloxacin and ciprofloxacin in human urine by ionic-liquid-based, dual-template molecularly imprinted coated graphene oxide monolithic solid-phase extraction
    Ma, Wanwan
    Row, Kyung Ho
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (03) : 642 - 649
  • [43] Development of an in-house mixed-mode solid-phase extraction for the determination of 16 basic drugs in urine by High Performance Liquid Chromatography-Ion Trap Mass Spectrometry
    Musile, Giacomo
    Cenci, Lucia
    Piletska, Elena
    Gottardo, Rossella
    Bossi, Alessandra M.
    Bortolotti, Federica
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1560 : 10 - 18
  • [44] An efficient mixed-mode strong anion-exchange adsorbent based on functionalized polyethyleneimine for simultaneous solid phase extraction and purification of bisphenol analogues and monoalkyl phthalate esters in human urine
    Huang, Chaonan
    Yang, Jiajia
    Ma, Jiping
    Tan, Weiqiang
    Wu, Lingxia
    Shan, Bin
    Wang, Shasha
    Chen, Jiping
    Li, Yun
    MICROCHEMICAL JOURNAL, 2022, 180
  • [45] Use of molecularly imprinted solid-phase extraction sorbent for the determination of four 5-nitroimidazoles and three of their metabolites from egg-based samples before tandem LC-ESIMS/MS analysis
    Mohamed, Rayane
    Mottier, Pascal
    Treguier, Laureen
    Richoz-Payot, Janique
    Yilmaz, Ecevit
    Tabet, Jean-Claude
    Guy, Philippe A.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (10) : 3500 - 3508
  • [46] Selective solid-phase extraction of naproxen drug from human urine samples using molecularly imprinted polymer-coated magnetic multi-walled carbon nanotubes prior to its spectrofluorometric determination
    Madrakian, Tayyebeh
    Ahmadi, Mazaher
    Afkhami, Abbas
    Soleimani, Mohammad
    ANALYST, 2013, 138 (16) : 4542 - 4549
  • [47] Determination of bencycloquidium bromide in human urine using weak cation-exchange solid-phase extraction and LC-ESI-MS: Method validation and application to kinetic study of urinary excretion
    Zhou, Wenjia
    Ding, Li
    Xu, Guili
    Wang, Yongqing
    Sun, Luning
    He, Jianchang
    Huang, Yao
    Hu, Linlin
    Chen, Xiaoping
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (01) : 35 - 40
  • [48] Development of an analytical method based on citric acid coated magnetite nanoparticles assisted dispersive magnetic solid-phase extraction for the enrichment and extraction of sildenafil, tadalafil, vardenafil and avanafil in human plasma and urine prior to determination by LC-MS/MS
    Er, Elif Orturk
    Akkaya, Erhan
    Ozbek, Belma
    Bakirdere, Sezgin
    MICROCHEMICAL JOURNAL, 2019, 147 : 269 - 276
  • [49] A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction, followed by high-speed liquid chromatography/mass spectrometry, for the determination of a basic drug in human plasma
    Xue, Y. -J.
    Akinsanya, J. Billy
    Liu, Jane
    Unger, Steve E.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (18) : 2660 - 2668
  • [50] FULLY AUTOMATED-ASSAY FOR THE DETERMINATION OF GR117289X IN HUMAN PLASMA USING MIXED-MODE SOLID-PHASE EXTRACTION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION
    MURKITT, GS
    TRAFANKOWSKA, EZ
    DUNNE, M
    MANCHEE, GR
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (09) : 1181 - 1187