Decreasing the total divergence of polycapillary X-ray microbeams

被引:0
|
作者
A. Yu. Romanov
机构
[1] Institute for Roentgen Optics,
来源
Technical Physics Letters | 2008年 / 34卷
关键词
41.50.+h;
D O I
暂无
中图分类号
学科分类号
摘要
The divergence characteristics of intense quasi-parallel X-ray microbeams have been studied at the output of the “microfocus X-ray generator-cylindrical polycapillary structure” system by scanning the beam with a knife edge. It us established that the total microbeam divergence decreases in the region near the output edge of the polycapillary structure (divergence quasi-decrease effect).
引用
收藏
页码:782 / 784
页数:2
相关论文
共 50 条
  • [31] Improved radiography with polycapillary x-ray optics
    MacDonald, CA
    Sugiro, FR
    Gibson, WM
    [J]. ADVANCES IN LABORATORY-BASED X-RAY SOURCES AND OPTICS II, 2001, 4502 : 10 - 18
  • [32] Numerical simulation of polycapillary X-ray lens
    Peng, Shiqi
    Liu, Zhiguo
    Sun, Tianxi
    Wang, Kai
    Yi, Longtao
    Yang, Kui
    Chen, Man
    [J]. Guangxue Xuebao/Acta Optica Sinica, 2015, 35 (02):
  • [33] POLYCAPILLARY-BASED X-RAY OPTICS
    XIAO, QF
    POTURAEV, SV
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3): : 376 - 383
  • [34] Energy dependence of x-ray beam size produced by polycapillary x-ray optics
    Das, Anusheela
    Heirwegh, Chris M.
    Gao, Ning
    Elam, William T.
    Wade, Lawrence A.
    Clark III, Benton C.
    Hurowitz, Joel A.
    Vanbommel, Scott J.
    Jones, Michael W. M.
    Allwood, Abigail C.
    [J]. X-RAY SPECTROMETRY, 2024,
  • [35] Performance of polycapillary x-ray lens for x-ray sources with various spot sizes
    Sun, Tianxi
    Liu, Zhiguo
    Ding, Xunliang
    [J]. X-RAY SPECTROMETRY, 2007, 36 (06) : 377 - 380
  • [36] X-ray spectrometry using polycapillary X-ray optics and position sensitive detector
    Ding, XL
    Xie, JD
    He, YJ
    Pan, QL
    Yan, YM
    [J]. TALANTA, 2000, 53 (01) : 17 - 22
  • [37] The monolithic X-ray polycapillary lens and its application in microbeam X-ray fluorescence
    Xie, JD
    He, YJ
    Ding, XL
    Pan, QL
    Yan, YM
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (03) : 391 - 394
  • [38] X-ray imaging on the base of Kumakhov polycapillary systems for hard X-ray region
    Nikitin, AN
    [J]. HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS, OPTICS, AND APPLICATIONS, 1997, 3115 : 143 - 146
  • [39] X-Ray Fluorescence Computed Tomography With Polycapillary Focusing
    Cong, Wenxiang
    Xi, Yan
    Wang, Ge
    [J]. IEEE ACCESS, 2014, 2 : 1138 - 1142
  • [40] Hard x-ray polycapillary telescope-II.
    Vartanian, MH