共 50 条
General correlation of two-phase frictional pressure drop inside smooth tubes
被引:0
|作者:
I Wayan Sugita
Afdhal Kurniawan Mainil
Akio Miyara
机构:
[1] Saga University,Graduate School of Science and Engineering
[2] Universitas Negeri Jakarta,Department of Mechanical Engineering
[3] Universitas Bengkulu,Department of Mechanical Engineering
[4] Saga University,Department of Mechanical Engineering
[5] International Institute for Carbon-Neutral Energy Research,undefined
[6] Kyushu University,undefined
来源:
关键词:
D O I:
暂无
中图分类号:
学科分类号:
摘要:
Calculating a two-phase pressure drop is required in many fields. A general and accurate correlation is still needed, although numerous studies of frictional pressure drop correlations have been conducted. Therefore, a wide range of experimental data points were collected on the two-phase pressure drop of smooth tubes, 2012 points, covering 16 refrigerants with tube diameters ranging from 1.88 to 12 mm. The experimental data points were compared and evaluated with nine widely used correlations and models. The results show that the (Kim and Mudawar in Journal of Int J Heat Mass Transf 55:3246-3261, 2012) correlation gives the best prediction, followed by the Wang et al. (Exp Therm Fluid Sci 15:395–405, 1997) correlation and Friedel (European Two-Phase Flow Group Meeting, Ispra, Italy, 1979) correlation with mean deviations of 26.94%, 27.26% and 29.76%, respectively. A general two-phase frictional pressure drop correlation is proposed. The proposed correlation is validated against the database and compared with other correlations. The proposed correlation agrees better with the database than the others, with an absolute mean deviation of 19.84%.
引用
收藏
页码:1009 / 1023
页数:14
相关论文