Stable-isotope dilution LC-MS/MS method for quantitative determination of microcystin conjugates with cysteine and glutathione in biotic matrices

被引:0
|
作者
Jiří Kohoutek
Tereza Procházková
Ondřej Adamovský
Miroslava Palíková
Klára Hilscherová
机构
[1] Masaryk University,RECETOX, Faculty of Science
[2] University of Veterinary and Pharmaceutical Sciences,Faculty of Veterinary Hygiene and Ecology
[3] Mendel University in Brno,Department of Zoology, Fisheries, Hydrobiology and Apiculture, Faculty of AgriSciences
来源
关键词
Microcystin; -Cysteine; -Glutathione; LC-MS/MS;
D O I
暂无
中图分类号
学科分类号
摘要
Microcystins are cyclic peptide toxins with hepatotoxic and tumor-promoting properties, which are produced in significant quantities (up to tens of μg/L) in freshwater cyanobacterial water blooms. Several studies reported microcystin accumulation in fish with possible food transfer to humans. These compounds are further metabolized to cysteine and glutathione conjugates which can be present in tissues in significant concentrations. In this study, we focused on the development and evaluation of robust and highly sensitive SPE-LC-MS/MS method for the analysis of microcystin conjugates in fish tissue samples. For the first time, we demonstrate the use of isotopically labeled internal standards which are essential for accurate and precise determination of analytes in complex biotic matrices. LLOQs of respective microcystin conjugates (signal-to-noise ratio; S/N > 10, peak-to-peak method) ranged from 3.3 to 5.0 ng/g of tissue fresh weight (FW). The calibration was linear within a range of concentrations from 1 to 70 ng/mL for all analyzed conjugates. The precision and repeatability of the method were very good with recoveries in the range of 88.5–107.6% and relative standard deviations between 8.8 and 13.2% for all analytes. In the follow-up study, fully validated method was used for the determination of microcystin conjugate levels in common carp exposed to microcystin-containing cyanobacterial biomass under controlled conditions. Significant amounts of microcystin conjugates (up to 55 ng/g) were found in the tissues of fish after 7 weeks of exposure. Our method was shown to be robust, sensitive, selective, and suitable for the determination of trace levels of microcystin conjugates in fish tissues.
引用
收藏
页码:5267 / 5275
页数:8
相关论文
共 50 条
  • [1] Stable-isotope dilution LC-MS/MS method for quantitative determination of microcystin conjugates with cysteine and glutathione in biotic matrices
    Kohoutek, Jiri
    Prochazkova, Tereza
    Adamovsky, Ondrej
    Palikova, Miroslava
    Hilscherova, Klara
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (20) : 5267 - 5275
  • [2] Stable-isotope dilution LC-MS for quantitative biomarker analysis
    Ciccimaro, Eugene
    Blair, Ian A.
    [J]. BIOANALYSIS, 2010, 2 (02) : 311 - 341
  • [3] Determination of nifurtimox in dog plasma by stable-isotope dilution LC-MS/MS
    Gnoth, Mark-Jean
    Hopfe, Peter-Michael
    Thuss, Uwe
    [J]. BIOANALYSIS, 2015, 7 (21) : 2777 - 2787
  • [4] A quantitative stable-isotope LC-MS method for the determination of folic acid fortified foods
    Pawlosky, RJ
    Flanagan, VP
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (03) : 1282 - 1286
  • [5] Simultaneous Quantitation of Cellular Cysteine, Homsteine, And Glutathione by Stable Isotope Dilution LC-MS
    Khartulyari, Stefanie
    Wei, Cong
    Whitehead, A. Steven
    Blair, Ian A.
    [J]. CHEMICAL RESEARCH IN TOXICOLOGY, 2008, 21 (12) : 2448 - 2448
  • [6] Determination of cyanocobalamin by isotope dilution LC-MS/MS
    D'Ulivo, Lucia
    Yang, Lu
    Ding, Jianfu
    Pagliano, Enea
    Leek, Donald M.
    Thibeault, Marie-Pier
    Mester, Zoltan
    [J]. ANALYTICA CHIMICA ACTA, 2017, 990 : 103 - 109
  • [7] Rapid method for the determination of multiple mycotoxins in wines and beers by LC-MS/MS using a stable isotope dilution assay
    Al-Taher, Fadwa
    Banaszewski, Katie
    Jackson, Lauren
    Zweigenbaum, Jerry
    Ryu, Dojin
    Cappozzo, Jack
    [J]. Journal of Agricultural and Food Chemistry, 2013, 61 (10): : 2378 - 2384
  • [8] Rapid Method for the Determination of Multiple Mycotoxins in Wines and Beers by LC-MS/MS Using a Stable Isotope Dilution Assay
    Al-Taher, Fadwa
    Banaszewski, Katie
    Jackson, Lauren
    Zweigenbaum, Jerry
    Ryu, Dojin
    Cappozzo, Jack
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (10) : 2378 - 2384
  • [9] Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in beer
    Habler, Katharina
    Gotthardt, Marina
    Schueler, Jan
    Rychlik, Michael
    [J]. FOOD CHEMISTRY, 2017, 218 : 447 - 454
  • [10] Development of a Stable Isotope Dilution LC-MS/MS Method for the Alternaria Toxins Tentoxin, Dihydrotentoxin, and Isotentoxin
    Liu, Yang
    Rychlik, Michael
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (12) : 2970 - 2978