Arthroscopic anterior cruciate ligament reconstruction with modified “wireless” cross-screw transfix femoral fixation

被引:0
|
作者
Fereidoon M. Jaberi
Ali Haghighat
Zahra Babanezhad
Mehrad M. Jaberi
机构
[1] Shiraz University of Medical Sciences,Department of Orthopedic Surgery
[2] McGill University,undefined
[3] Abbey College,undefined
关键词
Arthroscopic; Anterior cruciate reconstruction; Transfix; Hamstring;
D O I
暂无
中图分类号
学科分类号
摘要
Among several graft fixation options in arthroscopic ACL reconstruction for hamstring tendons, transcondylar fixation has been suggested to offer mechanical advantages compared to other femoral fixation systems. Blind nature of the procedure may result in several complications including iliotibial band irritation syndrome, breakage of the bio absorbable cross-pin, stress fracture of the femoral cortex, and more commonly intraoperative wire loop twisting, resulting in fixation failure, wire breakage or graft laceration. We used “wireless” transfixation technique to avoid complications associated with wire loop.
引用
收藏
页码:1508 / 1510
页数:2
相关论文
共 50 条
  • [1] Arthroscopic anterior cruciate ligament reconstruction with modified "wireless" cross-screw transfix femoral fixation
    Jaberi, Fereidoon M.
    Haghighat, Ali
    Babanezhad, Zahra
    Jaberi, Mehrad M.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (11) : 1508 - 1510
  • [2] A Pitfall of transfix fixation during anterior cruciate ligament reconstruction
    Choi, Nam-Hong
    Son, Kyung-Mo
    Victoroff, Brian N.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (05) : 479 - 481
  • [3] A pitfall of transfix fixation during anterior cruciate ligament reconstruction
    Nam-Hong Choi
    Kyung-Mo Son
    Brian N. Victoroff
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2008, 16 : 479 - 481
  • [4] Breakage of bioabsorbable femoral transfix screw after arthroscopic anterior cruciate ligament repair: a report of two cases
    A. Raviraj
    Ashish Anand
    K. Santosh
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2012, 22 : 185 - 188
  • [5] Breakage of bioabsorbable femoral transfix screw after arthroscopic anterior cruciate ligament repair: a report of two cases
    Raviraj, A.
    Anand, Ashish
    Santosh, K.
    [J]. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2012, 22 : 185 - 188
  • [6] Biosteon Cross Pin Femoral Fixation and Tibial Interference Screw Fixation for Hamstring Anterior Cruciate Ligament Reconstruction
    Stewart, Andrew M.
    Paulos, Lonnie E.
    [J]. TECHNIQUES IN ORTHOPAEDICS, 2005, 20 (03) : 254 - 260
  • [7] Intraoperative complications using the Bio-Transfix femoral fixation implant in anterior cruciate ligament reconstruction
    Kokkinakis, Michail
    Ashmore, Alexander
    El-Guindi, Magdi
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (03) : 375 - 379
  • [8] Intraoperative complications using the Bio-Transfix femoral fixation implant in anterior cruciate ligament reconstruction
    Michail Kokkinakis
    Alexander Ashmore
    Magdi El-Guindi
    [J]. Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 375 - 379
  • [9] Arthroscopic anterior cruciate ligament reconstruction using a hamstring graft with interference screw fixation
    Moisala, A. -S.
    Jaervelae, T.
    Honkonen, S.
    Paakkala, A.
    Kannus, P.
    Jaervinen, M.
    [J]. SCANDINAVIAN JOURNAL OF SURGERY, 2007, 96 (01) : 83 - 87
  • [10] Transcondylar screw fixation in anterior cruciate ligament reconstruction
    Mariani, PP
    Camillieri, G
    Margheritini, F
    [J]. ARTHROSCOPY, 2001, 17 (07): : 717 - 723