Breakage of bioabsorbable femoral transfix screw after arthroscopic anterior cruciate ligament repair: a report of two cases

被引:0
|
作者
A. Raviraj
Ashish Anand
K. Santosh
机构
[1] Fortis Hospitals,Department of Orthopedics
[2] Fortis Hospitals,Department of Radiology
[3] St Catherine Medical Center,undefined
关键词
Anterior cruciate ligament tear; Biotransfix; Failure; Breakage;
D O I
暂无
中图分类号
学科分类号
摘要
The reconstruction of anterior cruciate ligament (ACL) has become the standard of care for a torn ACL in active, young athletes. Various methods, graft options and techniques of reconstruction are published. The use of biotransfix bioabsorbable screw is one of the options of anchoring the graft on the femoral side. We describe the failure of transfix due to breakage in two patients after arthroscopic ACL reconstruction. These patients developed symptoms of screw irritation subcutaneously or skin penetration of the broken, migrated transfix pin. The clinical presentation, diagnosis, the image findings, management and review of literature are presented in this report. To the best of our knowledge, this is the only report from Asia.
引用
收藏
页码:185 / 188
页数:3
相关论文
共 50 条
  • [1] Breakage of bioabsorbable femoral transfix screw after arthroscopic anterior cruciate ligament repair: a report of two cases
    Raviraj, A.
    Anand, Ashish
    Santosh, K.
    [J]. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2012, 22 : 185 - 188
  • [2] Femoral Tunnel Widening After Hamstring Anterior Cruciate Ligament Reconstruction With Bioabsorbable Transfix
    Choi, Nam-Hong
    Son, Kyung-Mo
    Yoo, Soon-Young
    Victoroff, Brian N.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (02): : 383 - 387
  • [3] Arthroscopic anterior cruciate ligament reconstruction with modified "wireless" cross-screw transfix femoral fixation
    Jaberi, Fereidoon M.
    Haghighat, Ali
    Babanezhad, Zahra
    Jaberi, Mehrad M.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (11) : 1508 - 1510
  • [4] Arthroscopic anterior cruciate ligament reconstruction with modified “wireless” cross-screw transfix femoral fixation
    Fereidoon M. Jaberi
    Ali Haghighat
    Zahra Babanezhad
    Mehrad M. Jaberi
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 1508 - 1510
  • [5] Supracondylar femoral fracture after arthroscopic reconstruction of the anterior cruciate ligament - A case report
    Mithoefer, K
    Gill, TJ
    Vrahas, MS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (07): : 1591 - 1596
  • [6] A TECHNIQUE FOR ARTHROSCOPIC ANTERIOR CRUCIATE LIGAMENT REPAIR
    WHIPPLE, TL
    ELLIS, FD
    [J]. CLINICS IN SPORTS MEDICINE, 1991, 10 (03) : 463 - 468
  • [7] Iliotibial band friction syndrome after anterior cruciate ligament reconstruction using the transfix device: report of two cases and review of the literature
    Xavier Pelfort
    Joan C. Monllau
    LLuís Puig
    Enric Cáceres
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 586 - 589
  • [8] Iliotibial band friction syndrome after anterior cruciate ligament reconstruction using the transfix device:: report of two cases and review of the literature
    Pelfort, X
    Monllau, JC
    Puig, L
    Cáceres, E
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (06) : 586 - 589
  • [9] Transcutaneous migration of a tibial bioabsorbable interference screw after anterior cruciate ligament reconstruction
    Sassmannshausen, G
    Caff, CF
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (09):
  • [10] Clinical failure of tibial interference screw fixation after anterior cruciate ligament reconstruction - A report of two cases
    Cooper, DE
    Wilson, TW
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1996, 24 (05): : 693 - 697