Corrosion Failure Analysis on Heat Exchanger Pipes

被引:6
|
作者
Qiankun Z. [1 ]
Yafei S. [1 ]
Sixian R. [1 ]
Huifeng L. [1 ]
Xingjiang Z. [2 ]
机构
[1] School of Mechanical Engineering, Anhui University of Technology, Ma’anshan
[2] National Machine Quality Supervision and Inspection Center, Ma’anshan
关键词
Corrosion failure analysis; Failure analysis; Microstructure; Pitting;
D O I
10.1007/s11668-017-0248-9
中图分类号
学科分类号
摘要
The heat exchange pipes in one synthetic ammonia plant were in use for only thirteen months, but obvious leakage occurred in the pipes. Investigations indicated that corrosion of the pipes was quite serious, resulting in corrosion pits penetrating the pipes in some spots. Analysis on the metallurgical structure indicated that no problems existed on the pipe material AISI 1020 low carbon steel; the corrosion inhibitors or scale inhibitors were added in the circulating water. The only problem was deduced to exist in the maintenance of the pipes during the idling period; survey of the maintenance of the pipes during the idling period proved the deduction above. Since no effective measures were taken to protect the pipes in the coolers and the circulating water was not emptied, the corrosion products and scales deposited on the pipes and formed local occluded cells; the occluded cells accelerated the pitting corrosion of the pipes and induced leakage in a short time. © 2017, ASM International.
引用
收藏
页码:349 / 353
页数:4
相关论文
共 50 条
  • [21] Failure Analysis of a Heat Exchanger Shell
    Al-Shahrani, S.
    Al-Meshari, A.
    van Zyl, G. N.
    Ahmad, S.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2013, 13 (01) : 20 - 25
  • [22] Failure investigation of heat exchanger plates due to pitting corrosion
    Deen, K. M.
    Virk, M. A.
    Hague, C. I.
    Ahmad, R.
    Khan, I. H.
    ENGINEERING FAILURE ANALYSIS, 2010, 17 (04) : 886 - 893
  • [23] Investigation of failure of tubes in a heat exchanger for corrosion of dissolved oxygen
    Huang, Song
    Chen, Jie
    Zhang, Wenpin
    Xiong, Shutao
    2019 5TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2020, 440
  • [24] Failure Assessment of Heat Exchanger Tubes Due to Grooving Corrosion
    Ranjbar, Khalil
    Sharifi, Emad
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2023, 23 (02) : 739 - 750
  • [25] Failure Assessment of Heat Exchanger Tubes Due to Grooving Corrosion
    Khalil Ranjbar
    Emad Sharifi
    Journal of Failure Analysis and Prevention, 2023, 23 : 739 - 750
  • [26] Heat exchanger corrosion
    不详
    MATERIALS PERFORMANCE, 2002, 41 (09) : 65 - 66
  • [27] Stress relaxation cracking failure in heat exchanger connection pipes in a petrochemical plant
    Mallick, Ritesh Kumar
    Ghosh, Manojit
    Bahrami, Abbas
    Esmaeili, Vahid
    ENGINEERING FAILURE ANALYSIS, 2023, 147
  • [28] Numerical Analysis and Comparison of Various Cross Sections of Heat Pipes in Heat Exchanger
    Bhaskar, Gadipelly
    Rao, K. V. Narasimha
    Kumar, M. Udaya
    JOURNAL OF POLYMER & COMPOSITES, 2023, 11 : S74 - S81
  • [29] Acidic/caustic alternating corrosion on carbon steel pipes in heat exchanger of ethylene plant
    Gong, Y.
    Yang, C.
    Yao, C.
    Yang, Z. -G.
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2011, 62 (10): : 967 - 978
  • [30] Ant-nest corrosion failure of heat exchangers copper pipes
    Cozzarini, Luca
    Marsich, Lucia
    Schmid, Chiara
    ENGINEERING FAILURE ANALYSIS, 2020, 109