Real-time electrical detection of nitric oxide in biological systems with sub-nanomolar sensitivity

被引:0
|
作者
Shan Jiang
Rui Cheng
Xiang Wang
Teng Xue
Yuan Liu
Andre Nel
Yu Huang
Xiangfeng Duan
机构
[1] University of California,Department of Chemistry and Biochemistry
[2] University of California,Department of Materials Science and Engineering
[3] University of California,Division of NanoMedicine, Department of Medicine
[4] California NanoSystems Institute,undefined
[5] University of California,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Real-time monitoring of nitric oxide concentrations is of central importance for probing the diverse roles of nitric oxide in neurotransmission, cardiovascular systems and immune responses. Here we report a new design of nitric oxide sensors based on hemin-functionalized graphene field-effect transistors. With its single atom thickness and the highest carrier mobility among all materials, graphene holds the promise for unprecedented sensitivity for molecular sensing. The non-covalent functionalization through π–π stacking interaction allows reliable immobilization of hemin molecules on graphene without damaging the graphene lattice to ensure the highly sensitive and specific detection of nitric oxide. Our studies demonstrate that the graphene–hemin sensors can respond rapidly to nitric oxide in physiological environments with a sub-nanomolar sensitivity. Furthermore, in vitro studies show that the graphene–hemin sensors can be used for the detection of nitric oxide released from macrophage cells and endothelial cells, demonstrating their practical functionality in complex biological systems.
引用
收藏
相关论文
共 50 条
  • [21] Microelectrode electrochemical detection of nitric oxide in gut inflammation affords real time measurements and enhanced sensitivity
    Liu, X
    Ribbons, K
    Sandoval, M
    SadowskaKrowicka, H
    Clark, DA
    Miller, MJS
    GASTROENTEROLOGY, 1996, 110 (04) : A343 - A343
  • [22] Novel Insights into the Electrochemical Detection of Nitric Oxide in Biological Systems
    Pekarova, M.
    Lojek, A.
    Hrbac, J.
    Kuchta, R.
    Kadlec, J.
    Kubala, L.
    FOLIA BIOLOGICA, 2014, 60 : 8 - 12
  • [23] REAL-TIME CARDIAC ELECTRICAL BIOMARKER FOR DETECTION OF AMI
    Schreck, David M.
    Fishberg, Robert D.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E919 - E919
  • [24] A real-time system for the generation and detection of electrical disturbances
    Monedero, H
    León, C
    García, A
    Elena, JM
    Montaño, JC
    Ropero, J
    2004 IEEE PES POWER SYSTEMS CONFERENCE & EXPOSITION, VOLS 1 - 3, 2004, : 1019 - 1023
  • [25] Real-time electrical detection of coherent spin oscillations
    Hoehne, Felix
    Huck, Christian
    Brandt, Martin S.
    Huebl, Hans
    PHYSICAL REVIEW B, 2014, 89 (16):
  • [26] Real-time incipient fault detection for electrical traction systems of CRH2
    Chen, Hongtian
    Jiang, Bin
    Lu, Ningyun
    Chen, Wen
    NEUROCOMPUTING, 2018, 306 : 119 - 129
  • [27] Real-time visualization of distinct nitric oxide generation of nitric oxide synthase isoforms in single cells
    Eroglu, Emrah
    Hallstrom, Seth
    Bischof, Helmut
    Opelt, Marissa
    Schmidt, Kurt
    Mayer, Bernd
    Waldeck-Weiermair, Markus
    Graier, Wolfgang F.
    Malli, Roland
    NITRIC OXIDE-BIOLOGY AND CHEMISTRY, 2017, 70 : 59 - 67
  • [28] Sensitivity analysis of complex embedded real-time systems
    Racu, Razvan
    Hamann, Arne
    Ernst, Rolf
    REAL-TIME SYSTEMS, 2008, 39 (1-3) : 31 - 72
  • [29] Using higher organisms in biological early warning systems for real-time toxicity detection
    van der Schalie, WH
    Shedd, TR
    Knechtges, PL
    Widder, MW
    BIOSENSORS & BIOELECTRONICS, 2001, 16 (7-8): : 457 - 465
  • [30] Effect of cervical spinal cord electrical stimulation on nitric oxide levels in brain and dermal tissues: an evaluation using by real-time nitric oxide measurement
    Ozum, Unal
    Akyol, Melih
    Balaban, Hatice
    Ozdemir, Ercan
    Soydan, Serdar
    ACTA NEUROCHIRURGICA, 2012, 154 (09) : 1641 - 1646