Novel Hg2+-Selective Signaling Probe Based on Resorufin Thionocarbonate and its μPAD Application

被引:0
|
作者
Myung Gil Choi
So Young Park
Ka Young Park
Suk-Kyu Chang
机构
[1] Chung-Ang University,Department of Chemistry
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
In this study, a novel resorufin thionocarbonate-based Hg2+-selective signaling probe (RT) for microfluidic paper-based analytical device (μPAD) applications is reported. The designed probe, RT, was readily synthesized by the one-step reaction of resorufin with phenyl thionochloroformate. The RT probe displayed a prominent color change from yellow to pink and a marked turn-on fluorescence signaling behavior exclusively toward the Hg2+ ion. The signaling of RT was due to Hg2+-induced hydrolysis of the phenyl thionocarbonate moiety to form the parent resorufin dye, which restored its spectroscopic properties. In addition, RT exhibited the Hg2+-selective signaling behavior without interference by coexisting environmentally relevant metal ions. The detection limit for Hg2+ in simulated wastewater samples was estimated to be 5.8 × 10−8 M. In particular, an RT-equipped μPAD prepared using a wax printing technique enabled simple and convenient determination of Hg2+ ions in simulated wastewater samples, with a detection limit of 5.9 × 10−6 M.
引用
收藏
相关论文
共 50 条
  • [31] Hg2+-selective membrane potentiometric sensor based on a recently synthesized mercapto compound
    Bagheri, M
    Mashhadizadeh, MH
    Razee, S
    Momeni, A
    ELECTROANALYSIS, 2003, 15 (23-24) : 1824 - 1829
  • [32] Bodipy-based quinoline derivative as a highly Hg2+-selective fluorescent chemosensor and its potential applications
    Kumarasamy, Keerthika
    Devendhiran, Tamiloli
    Chien, Wei-Jyun
    Lin, Mei-Ching
    Ramasamy, Selva Kumar
    Yang, Ji-Jhang
    METHODS, 2024, 223 : 35 - 44
  • [33] New Hg2+-selective chromo- and fluoroionophore based upon 8-hydroxyquinoline
    Moon, SY
    Cha, NR
    Kim, YH
    Chang, SK
    JOURNAL OF ORGANIC CHEMISTRY, 2004, 69 (01): : 181 - 183
  • [34] Selective rhodamine-based probe for detecting Hg2+ and its application as test strips and cell staining
    Wang, Yuesong
    Ding, Haichang
    Zhu, Zifan
    Fan, Congbin
    Tu, Yayi
    Liu, Gang
    Pu, Shouzhi
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2020, 390 (390)
  • [35] Rhodamine-based Hg2+-selective chemodosimeter in aqueous solution:: Fluorescent OFF-ON
    Wu, Jia-Sheng
    Hwang, In-Chul
    Kim, Kwang S.
    Kim, Jong Seung
    ORGANIC LETTERS, 2007, 9 (05) : 907 - 910
  • [36] Hg2+-Selective Ratiometric and "Off-On" Chemosensor Based on the Azadiene-Pyrene Derivative
    Zhou, Yi
    Zhu, Chao-Yun
    Gao, Xu-Sheng
    You, Xue-Yan
    Yao, Cheng
    ORGANIC LETTERS, 2010, 12 (11) : 2566 - 2569
  • [37] Hg2+-selective OFF-ON and Cu2+-selective ON-OFF type fluoroionophore based upon cyclam
    Kim, SH
    Kim, JS
    Park, SM
    Chang, SK
    ORGANIC LETTERS, 2006, 8 (03) : 371 - 374
  • [38] Pyrene appended Hg2+-selective fluoroionophore based upon diaza-crown ether
    Choi, Myung Gil
    Kim, Hee Jung
    Chang, Suk-Kyu
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2008, 29 (03): : 567 - 570
  • [39] A resorufin-based fluorescent probe for hydrazine detection and its application in environmental analysis and bioimaging
    Ruan, Minghao
    Zhang, Bo
    Wang, Jiamin
    Fan, Guanwen
    Lu, Xiaoyan
    Zhang, Jian
    Zhao, Weili
    ANALYTICAL METHODS, 2023, 15 (46) : 6412 - 6416
  • [40] A highly selective colorimetric fluorescent probe for detection of Hg2+ and its application on test strips
    Yang, Geng
    Meng, Xia
    Fang, Shimin
    Duan, Hongdong
    Wang, Lizhen
    Wang, Zhenzheng
    RSC ADVANCES, 2019, 9 (15): : 8529 - 8536