Feasibility study of wearable capillary refill time measurement device

被引:0
|
作者
Masayoshi Shinozaki
Daiki Saito
Taka-aki Nakada
Yukihiro Nomura
Toshiya Nakaguchi
机构
[1] Chiba University,Department of Medical Engineering, Graduate School of Science and Engineering
[2] Chiba University Graduate School of Medicine,Department of Emergency and Critical Care Medicine
[3] Chiba University,Center for Frontier Medical Engineering
[4] The University of Tokyo Hospital,Department of Computational Diagnostic Radiology and Preventive Medicine
来源
关键词
Agreement analysis; Capillary refill time; Functional expansion; Quantification; Wearable device;
D O I
暂无
中图分类号
学科分类号
摘要
Capillary refill time (CRT) is an internationally accepted indicator of peripheral circulation. The CRT is measured by applying compression to the fingernail for a few seconds, releasing it, and observing the process of refilling of blood at the fingertip. The international guidelines for the management of sepsis and septic shock 2021 contains an additional new recommendation for CRT measurement to determine the peripheral circulation statuses of adult patients with septic shock. However, the current CRT measurement method lacks objectivity. Previous studies have reported the development of measurement devices and video analysis systems, which involve complex measurement environment construction and assume only in-hospital measurements. In addition, since medical workers are limited in the number of carrying medical devices, devices that can be used to obtain multiple biometric indicators in a single measurement are needed. Hence, a prototype wearable CRT measurement device was developed in this study, and its feasibility was evaluated by comparing the agreement, intra-class correlation coefficient, and coefficient of variation with those of a CRT measurement device developed in the past. The results indicated that mean CRTs between measurement methods were agreement, with moderate or better intra-rater reliability and no difference in coefficient of variation. Therefore, the results indicate the feasibility of the proposed wearable CRT device.
引用
收藏
页码:334 / 339
页数:5
相关论文
共 50 条
  • [41] Capillary Refill Time: Is It Still a Useful Clinical Sign?
    Pickard, Amelia
    Karlen, Walter
    Ansermino, J. Mark
    [J]. ANESTHESIA AND ANALGESIA, 2011, 113 (01): : 120 - 123
  • [42] CAPILLARY REFILL TIME IN THE NORMAL NEWBORN-INFANT
    MAISELS, MJ
    SCHWARTZ, L
    KRING, E
    [J]. PEDIATRIC RESEARCH, 1995, 37 (04) : A222 - A222
  • [43] PERIPHERAL CAPILLARY REFILL TIME IS UNRELIABLE IN TERM INFANTS
    Batey, N.
    Kwok, T. C.
    Dorling, J.
    Sharkey, D.
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 2016, 175 (11) : 1865 - 1865
  • [44] Capillary refill time in term neonates : Bedside Assessment
    Raichur D.V.
    Aralihond A.P.
    Kasturi A.V.
    Patil D.H.
    [J]. The Indian Journal of Pediatrics, 2001, 68 (7) : 613 - 615
  • [45] Portable measurement device to quantitatively measure capillary refilling time
    Shinozaki, Masayoshi
    Shimizu, Rika
    Saito, Daiki
    Nakada, Taka-aki
    Nakaguchi, Toshiya
    [J]. ARTIFICIAL LIFE AND ROBOTICS, 2022, 27 (01) : 48 - 57
  • [46] Portable measurement device to quantitatively measure capillary refilling time
    Masayoshi Shinozaki
    Rika Shimizu
    Daiki Saito
    Taka-aki Nakada
    Toshiya Nakaguchi
    [J]. Artificial Life and Robotics, 2022, 27 : 48 - 57
  • [47] First of It's Kind Capillary Refill Monitoring Device to Guide Resuscitation
    Sheridan, David C.
    [J]. CIRCULATION, 2020, 142
  • [48] VIDEO-BASED CAPILLARY REFILL TIME ASSESSMENT IN CHILDREN
    Nickel, Amanda
    Jiang, Shen
    Hanks, Jasmine
    Hunter, Ryan
    Napolitano, Natalie
    Nadkarni, Vinay
    Nishisaki, Akira
    [J]. CRITICAL CARE MEDICINE, 2021, 49 (01) : 30 - 30
  • [49] IS CAPILLARY REFILL TIME A USEFUL MARKER OF HAEMODYNAMIC STATUS IN NEONATES?
    Gale, Chris
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 2010, 95 (05) : 395 - U114
  • [50] Capillary refill time in the hands and feet of normal newborn infants
    Raju, NV
    Maisels, MJ
    Kring, E
    Schwarz-Warner, L
    [J]. CLINICAL PEDIATRICS, 1999, 38 (03) : 139 - 144