Design and Implementation of Overcurrent Protection Relay

被引:0
|
作者
Mohammed Y. Suliman
Mohammed Ghazal
机构
[1] Northern Technical University,Department of Computer Engineering, Technical College
[2] Northern Technical University,Department of Power Engineering, Technical College
关键词
Overcurrent relay; IDMT; TMS; TC; Peak value detector; Pickup current; Input/output port; FPAA;
D O I
暂无
中图分类号
学科分类号
摘要
Protective relays have been designed with different technologies resulting in electromechanical, solid-state, and numerical devices. Speed and reliability are the two most important characteristics of a protective relay. Other capabilities such as monitoring and recording are supposed to be of secondary priority. The new technology using combination of field-programmable analog arrays (FPAAs) and digital technologies seems to be a breakthrough and has the potential to provide better performance than the present-day numerical relays. The use of FPAAs for designing and implementing overcurrent relay is investigated. The modeling and simulation of a protected system using Matlab are described. Hardware implementation using FPAAs is described. The practical test for different types of fault conditions is presented. The practical results show the ability of the new protection to response to the steady-state fault condition fastly and also can obtain different types of Time–Current characteristics with high accuracy. Also two types of characteristics Inverse Definite Minimum Time type IDMT type and very-inverse type are implemented, the protection system is tested in a fault of line-to-line type and the results show the ability to discriminate the fault condition and isolate the faulted section only, the remaining network can operate normally.
引用
收藏
页码:1595 / 1605
页数:10
相关论文
共 50 条
  • [31] Coordination of Directional Overcurrent Protection Relay for Distribution Network With Embedded DG
    Farkhani, J. Sahebkar
    Zareein, M.
    Soroushmehr, H.
    Mortazavi, H.
    2019 IEEE 5TH CONFERENCE ON KNOWLEDGE BASED ENGINEERING AND INNOVATION (KBEI 2019), 2019, : 281 - 286
  • [32] Effects of Distributed Generation on Overcurrent Relay Coordination and an Adaptive Protection Scheme
    Ilik, Semih C.
    Arsoy, Aysen B.
    INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY ENGINEERING, 2017, 73
  • [33] Design and Implementation of Microcontroller Based Starting and Protection Relay for Induction Motors
    Bayindir, Ramazan
    Demirbas, Sevki
    Irmak, Erdal
    Bekiroglu, Erdal
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2007, 10 (01): : 1 - 5
  • [34] Design of Overcurrent Protection Circuit for GaN HEMT
    Huang, Bo
    Li, Yan
    Zheng, Trillion Q.
    Zhang, Yajing
    2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 2844 - 2848
  • [35] IMPROVED MOTOR PROTECTION VIA THERMALLY DELAYED OVERCURRENT RELAY WITH PHASE FAILURE PROTECTION - REPLY
    SECK, A
    ELEKTROTECHNISCHE ZEITSCHRIFT B-AUSGABE, 1976, 28 (17): : 581 - 581
  • [36] Smart Distribution Protection Using Current-Only Directional Overcurrent Relay
    Ukil, Abhisek
    Deck, Bernhard
    Shah, Vishal H.
    2010 IEEE PES CONFERENCE ON INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT EUROPE), 2010,
  • [37] Highly sensitive microgrid protection using overcurrent relays with a novel relay characteristic
    Darabi, Ahmad
    Bagheri, Mehdi
    Gharehpetian, B. Gevork
    IET RENEWABLE POWER GENERATION, 2020, 14 (07) : 1201 - 1209
  • [38] Sensitivity and Selectivity of Time Overcurrent Relay Protection in Medium Voltage Power Lines
    Mehmed-Hamza, Mediha
    Stanchev, Plamen
    7TH INTERNATIONAL CONFERENCE ON ENERGY EFFICIENCY AND AGRICULTURAL ENGINEERING (EE&AE), 2020,
  • [39] Overcurrent Protection
    Telematics Ind, 9 (60):
  • [40] Multi-characteristic overcurrent relay of feeder protection for minimum tripping times and self-protection
    Reda, Abdallah
    Abdelgawad, Amal F.
    Elsayed, Mohamed I.
    Al-Dousar, Fhaid B.
    ELECTRICAL ENGINEERING, 2023, 105 (02) : 605 - 617