Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements

被引:42
|
作者
Ma I.W.Y. [1 ,2 ]
Caplin J.D. [3 ]
Azad A. [1 ,4 ]
Wilson C. [1 ]
Fifer M.A. [3 ]
Bagchi A. [5 ]
Liteplo A.S. [1 ]
Noble V.E. [1 ,6 ]
机构
[1] Division of Emergency Ultrasound, Department of Emergency Medicine, Massachusetts General Hospital, 326 Cambridge Street, Suite 410, Boston, 02114, MA
[2] Division of General Internal Medicine, Department of Medicine, University of Calgary, 3330 Hospital Dr NW, Calgary, T2N 4N1, AB
[3] Cardiology Division, Department of Medicine, Massachusetts General Hospital, 15 Parkman Street #800, Boston, 02114, MA
[4] Department of Emergency Medicine, Hamad Medical Corporation, PO Box 3050, Doha
[5] Department of Anaesthesia, Massachusetts General Hospital, 55 Fruit Street, Boston, 02114, MA
[6] Department of Emergency Medicine, University Hospitals, Cleveland Medical Center, Case Western Reserve University, 11100 Euclid Ave, Cleveland, 44106, OH
关键词
Cardiac output; Carotid blood flow; Carotid flow time; Carotid ultrasound;
D O I
10.1186/s13089-017-0065-0
中图分类号
学科分类号
摘要
Background: Non-invasive measures that can accurately estimate cardiac output may help identify volume-responsive patients. This study seeks to compare two non-invasive measures (corrected carotid flow time and carotid blood flow) and their correlations with invasive reference measurements of cardiac output. Consenting adult patients (n = 51) at Massachusetts General Hospital cardiac catheterization laboratory undergoing right heart catheterization between February and April 2016 were included. Carotid ultrasound images were obtained concurrently with cardiac output measurements, obtained by the thermodilution method in the absence of severe tricuspid regurgitation and by the Fick oxygen method otherwise. Corrected carotid flow time was calculated as systole time/√cycle time. Carotid blood flow was calculated as π × (carotid diameter)2/4 × velocity time integral × heart rate. Measurements were obtained using a single carotid waveform and an average of three carotid waveforms for both measures. Results: Single waveform measurements of corrected flow time did not correlate with cardiac output (ρ = 0.25, 95% CI −0.03 to 0.49, p = 0.08), but an average of three waveforms correlated significantly, although weakly (ρ = 0.29, 95% CI 0.02–0.53, p = 0.046). Carotid blood flow measurements correlated moderately with cardiac output regardless of if single waveform or an average of three waveforms were used: ρ = 0.44, 95% CI 0.18–0.63, p = 0.004, and ρ = 0.41, 95% CI 0.16–0.62, p = 0.004, respectively. Conclusions: Carotid blood flow may be a better marker of cardiac output and less subject to measurements issues than corrected carotid flow time. © 2017, The Author(s).
引用
收藏
相关论文
共 50 条
  • [21] Correlation Between Doppler Derived Carotid Artery Corrected Flow Time and Pressure Transducer Derived Radial Artery Corrected Flow Time: A Prospective Observational Study
    Maitra, Souvik
    Bhattacharjee, Sulagna
    Baidya, Dalim K.
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2020, 11 (02) : 128 - 133
  • [22] Correlation Between Doppler Derived Carotid Artery Corrected Flow Time and Pressure Transducer Derived Radial Artery Corrected Flow Time: A Prospective Observational Study
    Souvik Maitra
    Sulagna Bhattacharjee
    Dalim K. Baidya
    Cardiovascular Engineering and Technology, 2020, 11 : 128 - 133
  • [23] Blood flow in the common carotid artery in term and preterm infants: reproducibility and relation to cardiac output
    Sinha, AK
    Cane, C
    Kempley, ST
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2006, 91 (01): : F31 - F35
  • [24] Correction: Correlation of carotid corrected flow time and respirophasic variation in blood flow peak velocity with stroke volume variation in elderly patients under general anaesthesi
    Yu Chen
    Ziyou Liu
    Jun Fang
    Yanhu Xie
    Min Zhang
    Jia Yang
    BMC Anesthesiology, 23
  • [25] Change in Carotid Blood Flow and Carotid Corrected Flow Time Assessed by Novice Sonologists Fails to Determine Fluid Responsiveness in Spontaneously Breathing Intensive Care Unit Patients
    Abbasi, Adeel
    Azab, Nader
    Nayeemuddin, Mohammed
    Schick, Alexandra
    Lopardo, Thomas
    Phillips, Gary S.
    Merchant, Roland C.
    Levy, Mitchell M.
    Blaivas, Michael
    Corl, Keith A.
    Ultrasound in Medicine and Biology, 2020, 46 (10): : 2659 - 2666
  • [26] CHANGE IN CAROTID BLOOD FLOW AND CAROTID CORRECTED FLOW TIME ASSESSED BY NOVICE SONOLOGISTS FAILS TO DETERMINE FLUID RESPONSIVENESS IN SPONTANEOUSLY BREATHING INTENSIVE CARE UNIT PATIENTS
    Abbasi, Adeel
    Azab, Nader
    Nayeemuddin, Mohammed
    Schick, Alexandra
    Lopardo, Thomas
    Phillips, Gary S.
    Merchant, Roland C.
    Levy, Mitchell M.
    Blaivas, Michael
    Corl, Keith A.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (10): : 2659 - 2666
  • [27] Carotid Flow as a Surrogate for Cardiac Output Measurement in Hemodynamically Stable Participants
    Sidor, Marian
    Premachandra, Lalith
    Hanna, Bishoy
    Nair, Nanda
    Misra, Amit
    JOURNAL OF INTENSIVE CARE MEDICINE, 2020, 35 (07) : 650 - 655
  • [28] Cerebral Blood Flow and Internal Carotid Artery Flow During Carotid Surgery
    Boysen, Gudrun
    Ladegaard-Pedersen, H. J.
    Valentin, N.
    Engell, H. C.
    STROKE, 1970, 1 (04) : 253 - 260
  • [29] Cerebral blood flow measurements and electroencephalograms during carotid endarterectomy
    Sundt, Thoralf M., Jr.
    Sharbrough, Frank W.
    Anderson, Robert E.
    Michenfelder, John D.
    JOURNAL OF NEUROSURGERY, 2007, 107 (04) : 887 - 897
  • [30] Cardiac function and carotid blood flow in patients with cerebrovascular disease
    Hristova, K.
    Titianova, E.
    Milanov, S.
    JOURNAL OF HYPERTENSION, 2007, 25 : S224 - S225