Evaluation of post-dilatation on longitudinal stent deformation and postprocedural stent malapposition in the left main artery by optical coherence tomography (OCT): an in vitro study

被引:0
|
作者
Qing He
Yuqi Fan
Zuojun Xu
Junfeng Zhang
机构
[1] Shanghai Ninth People’s Hospital,Department of Cardiology
[2] Shanghai Jiaotong University School of Medicine,undefined
来源
BMC Medical Imaging | / 24卷
关键词
Optical coherence tomography; Vessel; Longitudinal stent deformation; Stent malapposition;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [21] Longitudinal Stent Deformation Caused by Optical Coherence Tomography Pullback in Percutaneous Coronary Intervention
    Kao, Ting-Wei
    Huang, Chin-Chou
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (14) : S154 - S155
  • [22] Classification of mechanisms of strut malapposition after angiographically optimized stent implantation: An optical coherence tomography study
    Agrawal, Mayank
    Hakeem, Abdul
    Ahmed, Zubair
    Uretsky, Barry F.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (02) : 225 - 232
  • [23] The effects of stent post-dilatation during primary percutaneous coronary intervention (PPCI) for ST-elevation myocardial infarction (STEMI): Insights from optical coherence tomography (OCT) and coronary physiology
    Karamasis, Grigoris
    Kalogeropoulos, Andreas
    Marco, Valeria
    Al-Janabi, Firas
    Toor, Iqbal
    Cook, Christopher
    Jagathesan, Rohan
    Kabir, Alamgir
    Sayer, Jeremy
    Robinson, Nicholas
    Aggarwal, Rajesh
    Clesham, Gerald
    Gamma, Reto
    Kelly, Paul
    Tang, Kare
    Prati, Francesco
    Keeble, Thomas
    Davies, John
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B29 - B29
  • [24] Combined intracoronary 2D–3D optical coherence tomography and intravascular ultrasound imaging in left main severe stent malapposition
    Cerrato E.
    Biagioni C.
    Jimenez-Quevedo P.
    Nuñez-Gil I.J.
    Gonzalo N.
    Escaned J.
    Cardiovascular Intervention and Therapeutics, 2018, 33 (3) : 288 - 290
  • [25] A catastrophic nightmare of the interventional cardiologist: Iatrogenic left main artery dissection and longitudinal stent deformation
    Yildirim, Oguz
    Gul, Murat
    Inci, Sinan
    Aktas, Halil
    Dogan, Pinar
    Bozkir, Abdulkadir
    Izgu, Ibrahim
    Karatas, Recep
    INTRACTABLE & RARE DISEASES RESEARCH, 2018, 7 (03) : 209 - 212
  • [26] Longitudinal Stent Deformation at the Proximal Segment of the Left Main Coronary Artery Caused by a Stuck OCT Catheter: Case Report and Review of Literature
    Zhang, Ming
    Pan, Xietian
    Wang, Yabin
    Yin, Shuo
    Bai, Peng
    Gao, Lei
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2024, 25 (04)
  • [27] OPTICAL COHERENCE TOMOGRAPHY EVALUATION OF A PLA BIORESORBABLE STENT IN A SWINE CORONARY ARTERY MODEL
    Nakano, Masataka
    Pacheco, Erica
    Acampado, Ed
    Otsuka, Fumiyuki
    Sakakura, Kenichi
    Kolodgie, Frank
    Lafont, Antonie
    Virmani, Renu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1648 - E1648
  • [28] Modified stent platform favorably affects longitudinal stent strength and stent deformation of the platinum chromium everolimus-eluting stent: an in vivo frequency domain optical coherence tomography
    Okura, H.
    Yamada, R.
    Yoshida, K.
    EUROPEAN HEART JOURNAL, 2015, 36 : 489 - 489
  • [29] SERIAL CHANGES OF TINY STENT MALAPPOSITION NOT DETECTED BY INTRAVASCULAR ULTRASOUND: FOLLOW-UP OPTICAL COHERENCE TOMOGRAPHY STUDY
    Kim, Won Ho
    Hong, Myeong-Ki
    Shim, Jaemin
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [30] Serial changes of minimal stent malapposition not detected by intravascular ultrasound: follow-up optical coherence tomography study
    Won Ho Kim
    Byoung Kwon Lee
    Sahng Lee
    Jae-Min Shim
    Jung-Sun Kim
    Byoung-Keuk Kim
    Young-Guk Ko
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    Clinical Research in Cardiology, 2010, 99 : 639 - 644