Two kinds of electrochemical immunoassays for the tumor necrosis factor α in human serum using screen-printed graphite electrodes modified with poly(anthranilic acid)

被引:0
|
作者
Mohammad Mazloum-Ardakani
Laleh Hosseinzadeh
Zahra Taleat
机构
[1] Yazd University,Department of Chemistry, Faculty of Science
来源
Microchimica Acta | 2014年 / 181卷
关键词
Immunoassay; Screen-printed electrode; Poly-anthranilic acid; Tumor necrosis factor α;
D O I
暂无
中图分类号
学科分类号
摘要
We present two kinds of electrochemical immunoassays for the tumor necrosis factor α (TNF-α) which is a protein biomarker. The antibody against TNF-α was immobilized on a graphite screen-printed electrode modified with poly-anthranilic acid (ASPE). The first is based on impedimetry (and thus label-free) and the target antigen (TNF-α) is captured by the surface of the modified electrode via an immunoreaction upon which impedance is changed. This sensing platform has a detection limit of 5.0 pg mL−1. In the second approach, the monoclonal antibodies on the modified electrode also bind to the target antigen (TNF-α), but detection is based on a sandwich immunoreaction. This is performed by first adding secondary anti-TNF-α antibodies labeled with horseradish peroxidase, and then detecting the response of the sandwich system by adding hydrogen peroxide and acetaminophen as a probe system for HRP activity. This immunosensor also has a very low detection limit (3.2 pg mL−1). The experimental conditions of both assays were studied and optimized via electrochemical impedance spectroscopy and differential pulse voltammetry. The method was then applied to the determination of TNF-α in serum samples where it displayed high sensitivity, selectivity and reproducibility.
引用
下载
收藏
页码:917 / 924
页数:7
相关论文
共 50 条
  • [31] Development of an electrochemical immunosensor for specific detection of visceral leishmaniasis using gold-modified screen-printed carbon electrodes
    Martins B.R.
    Barbosa Y.O.
    Andrade C.M.R.
    Pereira L.Q.
    Simão G.F.
    de Oliveira C.J.
    Correia D.
    Oliveira R.T.S.
    da Silva M.V.
    Silva A.C.A.
    Dantas N.O.
    Rodrigues V.
    Muñoz R.A.A.
    Alves-Balvedi R.P.
    Biosensors, 2020, 10 (08):
  • [32] Electrochemical Sensing and Removal of Cesium from Water Using Prussian Blue Nanoparticle-Modified Screen-Printed Electrodes
    Pandey, Prem C.
    Yadav, Hari Prakash
    Shukla, Shubhangi
    Narayan, Roger J.
    CHEMOSENSORS, 2021, 9 (09)
  • [33] Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes
    Martins, Beatriz R.
    Barbosa, Yanne O.
    Andrade, Cristhianne M. R.
    Pereira, Loren Q.
    Simao, Guilherme F.
    de Oliveira, Carlo J.
    Correia, Dalmo
    Oliveira Jr, Robson T. S.
    da Silva, Marcos, V
    Silva, Anielle C. A.
    Dantas, Noelio O.
    Rodrigues Jr, Virmondes
    Munoz, Rodrigo A. A.
    Alves-Balvedi, Renata P.
    BIOSENSORS-BASEL, 2020, 10 (08):
  • [34] Sensitive detection of ascorbic acid using screen-printed electrodes modified by electroactive melanin-like nanoparticles
    Argoubi, Wicem
    Rabti, Amal
    Ben Aoun, Sami
    Raouafi, Noureddine
    RSC ADVANCES, 2019, 9 (64) : 37384 - 37390
  • [35] Electrochemical Sensing of Uric Acid Using a ZnO/Graphene Nanocomposite Modified Graphite Screen Printed Electrode
    Rezaei, Rasoul
    Foroughi, Mohammad Mehdi
    Beitollahi, Hadi
    Alizadeh, Reza
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2018, 54 (11) : 860 - 866
  • [36] Electrochemical Sensing of Uric Acid Using a ZnO/Graphene Nanocomposite Modified Graphite Screen Printed Electrode
    Rasoul Rezaei
    Mohammad Mehdi Foroughi
    Hadi Beitollahi
    Reza Alizadeh
    Russian Journal of Electrochemistry, 2018, 54 : 860 - 866
  • [37] Electrochemical lactate biosensor based upon chitosan/carbon nanotubes modified screen-printed graphite electrodes for the determination of lactate in embryonic cell cultures
    Hernandez-Ibanez, Naiara
    Garcia-Cruz, Leticia
    Montiel, Vicente
    Foster, Christopher W.
    Banks, Craig E.
    Iniesta, Jesus
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 1168 - 1174
  • [38] Electrochemical performance of passivated antimonene nanosheets and of in-situ prepared antimonene oxide-PEDOT:PSS modified screen-printed graphite electrodes
    Lazanas, Alexandros Ch
    Prodromidis, Mamas, I
    ELECTROCHIMICA ACTA, 2022, 410
  • [39] Evaluation of the Usefulness of an Electrochemical Sensor in Detecting Ascorbic Acid using a Graphite Screen-printed Electrode Modified with NiFe2O4 Nanoparticles
    Jahani, Shohreh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 739 - 750
  • [40] Electrochemical detection of human papillomavirus DNA type 16 using a pyrrolidinyl peptide nucleic acid probe immobilized on screen-printed carbon electrodes
    Jampasa, Sakda
    Wonsawat, Wanida
    Rodthongkum, Nadnudda
    Siangproh, Weena
    Yanatatsaneejit, Pattamawadee
    Vilaivan, Tirayut
    Chailapakul, Orawon
    BIOSENSORS & BIOELECTRONICS, 2014, 54 : 428 - 434